ACURITE 00484 Weather Forecaster with Temperature and Humidity Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
- Unpacking Instructions
- Package Contents
- PRODUCT REGISTRATION
- Features & Benefits
- OUTDOOR SENSOR
- FRONT OF DISPLAY
- BACK OF DISPLAY
- SETUP
- Display Setup
- Set the Time, Date & Units
- Placement for Maximum Accuracy
- Setup is Complete
- OPERATION
- Barometric Pressure
- Programmable Alarms
- Troubleshooting
- Care & Maintenance
- Calibrate Barometric Pressure
- Specifications
- FCC Information
- Customer Support
- Limited 1-Year Warranty
- Documents / Resources
Instruction Manual
Weather Station
models 00484 / 00506 / 00524
Questions? Contact Customer Support at
877-221-1252 or visit
www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display
- Outdoor Sensor
- Power Adapter
- Instruction Manual
PRODUCT MUST BE REGISTERED
IMPORTANT
TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection www.AcuRite.com
Features & Benefits
OUTDOOR SENSOR
-
Integrated Hanger
For easy placement. -
Wireless Signal Indicator
Flashes when data is being sent to the display. -
Battery Compartment Cover
FRONT OF DISPLAY
-
Sensor Low Battery Indicator
-
Outdoor Sensor Signal Strength
-
Current Outdoor Temperature
The arrow icon indicates the direction temperature is trending. -
Outdoor Low-Temperature Record
The lowest temperature was recorded since midnight. -
Outdoor High-Temperature Record
The highest temperature was recorded since midnight. -
Icon
Indicates display is in auto-dimming
brightness mode (see page 7). -
Alarm ON/OFF Indicator
-
Date
-
Display Low Battery Indicator
-
Clock****
-
Current Indoor Temperatur
The arrow icon indicates the direction temperature is trending. -
Humidity Level Indicator
Indicates a high, low, or ideal humidity comfort level. -
Current Indoor Humidity
The arrow icon indicates the direction humidity is trending. -
Current Barometric Pressure
The arrow icon indicates the direction pressure is trending. -
12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast. -
Backlight Button
For momentary backlight and dimmer settings
BACK OF DISPLAY
-
SET Button
For setup preferences. -
& Buttons
For setup preferences. -
Button
For alarm setup. -
RESET Button
Full reset to factory defaults. -
Foldout Tabletop Stand****
-
Battery Compartment
-
Plug-in for Power Adapter
-
Battery Compartment Cover
-
Integrated Hang Hole
For easy wall mounting. -
Power Adapter
(not shown)
SETUP
Sensor Setup
Install or Replace Batteries cuRite recommends high-quality alkaline or
lithium batteries in the outdoor sensor for the best product performance.
Heavy duty or rechargeable batteries are not recommended.
The sensor requires lithium batteries in low-temperature conditions. Cold
temperatures can cause alkaline batteries to function improperly. Use lithium
batteries in the sensor for
temperatures below -4ºF / -20ºC.
- Slide off the battery compartment cover.
- Insert 2 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
- Replace the battery cover.
Display Setup
-
Install or Replace Backup Batteries (optional)
AcuRite recommends high-quality alkaline batteries in the display for the best product performance. Heavy duty or rechargeable batteries are not recommended.
1. Remove the battery compartment cover.
2. Insert 3 x AAA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/–) diagram in the battery compartment.
3. Replace the battery cover. -
Plug-in Power Adapter
For the best performance, plug in the power adapter as the main power source for this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device
prior to battery installation. Remove batteries from equipment that will not
be used for an extended period of time. Follow the polarity (+/-) diagram in
the battery compartment. Promptly remove dead batteries from the device.
Dispose of used batteries properly. Only batteries of the same or equivalent
type as recommended are to be used. DO NOT incinerate used batteries. DO NOT
dispose of batteries in free, as batteries may explode or leak. DO NOT mix old
and new batteries or types of batteries (alkaline/standard). DO NOT use
rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT
short-circuit the supply terminals.
Set the Time, Date & Units
Press and release the SET button to enter SETUP MODE. Once in setup mode, the
preference you are currently setting will blink on the display.
To adjust the currently selected (flashing) item, press and release the “▲” or
“▼” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the SET button again to adjust the
next preference. The preference set order is as follows:
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (ºF or ºC)
BAROMETRIC PRESSURE UNITS (inHg or hPa)
You will automatically exit SETUP MODE if no buttons are pressed for 8
seconds. Enter setup mode at any time by pressing the SET button.
Display Backlight Settings
This weather station’s color display features three different lighting
settings:
High (100%) brightness, Medium (60%) brightness and Low (15%) brightness. When
the display is powered with the power adapter, the backlight remains on at
100% brightness. Press the backlight button once to dim to 60% brightness;
press again to dim to 15%, press a 3rd time to enter “AUTO DIM” mode.
AUTO DIM MODE : Automatically adjusts display brightness based on time of day.
6:00 a.m. – 9:00 p.m. = 100% brightness
9:01 p.m. – 5:59 a.m.= 15% brightness
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display and outdoor sensor are critical to the accuracy
and performance of this product.
Display Placement
Place the display in a dry area free of dirt and dust. Display stands upright
for tabletop use or is wall-mountable.
Outdoor Sensor Placement
Sensors must be placed outside to observe outdoor conditions. The sensor is
water-resistant and is designed for general outdoor use, however, to extend
its life place the sensor in an area protected from direct weather elements.
Hang the sensor using the integrated hang holes or hanger, or by using string
(not included) to hang it from a suitable location, like a well-covered tree
branch. The best location is 4 to 8 feet above the ground with permanent shade
and plenty of fresh air to circulate around the sensor.
Important Placement Guidelines
- To ensure accurate temperature measurement, place units out of direct sunlight and away from any heat sources or vents.
- Display and outdoor sensors must be within 165 ft (50 m) of each other.
- To maximize wireless range, place units away from large metallic items, thick walls, metal surfaces, or other objects that may limit wireless communication.
- To prevent wireless interference, place both units at least 3 ft (.9 m) away from electronic devices (TV, computer, microwave, radio, etc.).
Setup is Complete
The sensor will now synchronize with the display. It may take a few minutes for synchronization to complete. Please refer to the troubleshooting section of this manual if anything appears to be functioning improperly.
OPERATION
Using the Weather Station
Learning Mode
Self-Calibrating Forecasting uses a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the Learning Mode icon disappears from the display screen. At
this point, the self-calibrated pressure is tuned in to your location and the
unit is ready for superior weather prediction.
Weather Forecast
AcuRite’s patented Self-Calibrating Forecasting provides your personal
forecast of weather conditions for the next 12 to 24 hours by collecting data
from the sensor in your backyard. It generates a forecast with pinpoint
accuracy – personalized for your exact location. Depending on your model,
weather forecast icons will be displayed in one of the two versions shown
below.
View
the complete list of icons at www.AcuRite.com/acurite-
icons
Barometric Pressure
Subtle variations in barometric pressure greatly affect the weather. This weather station displays the current pressure with an arrow icon to indicate the direction the pressure is trending (FALLING, STEADY, or RISING).
Programmable Alarms
This display features programmable alarms that sound an alert to notify you when a value (for temperature or humidity) has been reached or exceeded. When an alarm is triggered, the display emits an audible beep and flashes data in the affected category. You can customize the alarms by turning ON or OFF the alarms you’d like activated or deactivated, and by inputting your own values to trigger the alarm.
Set up an Alarm
- Press and release the “ ” button until the reading for which you wish to set an alarm is shown on the display. “ ” will be shown.
- Press and release the “ “ or “ “ buttons until “ ” appears.
- Press and release the “SET” button. The current HIGH alarm value will be shown.
- Press and release the “ “ or “ “ buttons to adjust the alarm’s HIGH value.
- Press and release the “SET” button. The current LOW alarm value will be shown.
- Press and release the “ “ or “ “ buttons to adjust the alarm’s LOW value.
- Press and release the “SET” button to end alarm adjustments, OR press and release the “ ” button to adjust the next alarm’s values.
Disable an Alarm
- Press and release the “ ” button until the reading for which you wish to disable an alarm is shown on the display. “will be shown.
- Press and release the“ “ or “ “ buttons until “ ” appears.
- Press and release the “button to cycle to the next reading.
- Repeat steps 1-3, as needed.
Note: To disable ALL alarms at once, press and HOLD the “button for 10
seconds.
You will automatically exit the alarm SET MODE if no buttons are pressed for
10 seconds. Enter alarm SET MODE at any time by pressing the “ ” button.
Troubleshooting
Problem | Possible Solution |
---|---|
No outdoor sensor retention no bars | If the wireless signal indicator |
shows no bars:
•Relocate the display and/or the outdoor sensor. The units must be within 165
ft (50 m) of each other.
•Make sure both units are placed at least 3 feet (.9 m) away from electronics
that may interfere with the wireless communication (such as TVs, microwaves,
computers, etc).
•Use standard alkaline batteries for lithium batteries in the sensor when the
temperature is below -41/20°C). Do not use heavy-duty or rechargeable
batteries. NOTE: It may take a few minutes for the display and sensor to
synchronize after batteries are replaced.
Display screen not working| •Check that the power adapter is plugged
into the display and an electrical outlet.
Outdoor temperature is flashing or showing dashes| Flashing of the
outdoor temperature is generally an indication of wireless interference.
1. Bring both the sensor and display indoors, side by side, and remove power
adapter/batteries from each.
2. Reinstall batteries in the outdoor sensor.
3. Reinstall power adopter/butteries in the display. A. Let the units sit
within o couple of feet of each other for a few minutes to gain a strong
connection.
Inaccurate forecast| •Weather Forecast icon predicts conditions for the
next 12 to 24 hours, not current conditions.
•Has the Learning Mode icon disappeared from the display? Learning Mode must
complete before forecast and pressure will be accurate.
•Allow the unit to run continuously for 33 days. Battery removal or resetting
the display will restart Learning Mode. After IA days, the forecast should be
fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature or humidity| •Make sure both the display and
sensor are placed out of direct twilight and away from any heat sources or
vents (see page 8).
•Make sure the display is positioned away from moisture sources (see page 8).
If your AcuRite product does not operate properly after trying the
troubleshooting steps, visit www.AcuRite.com or call
877-221-1252 for assistance.
Care & Maintenance
Display Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Outdoor Sensor Care
Clean with a soft damp cloth. Do not use caustic cleaners or abrasives.
Calibration
Calibrate Temperature & Humidity
The indoor temperature and humidity and outdoor temperature readings can be
calibrated on the display to improve accuracy. Calibration can improve
accuracy when sensor placement or environmental factors impact your data
accuracy.
- To access calibration mode, press AND HOLD the “▲”, “▼”, and “SET” buttons for at least 5 seconds.
- Once in calibration mode, the preference you are currently setting will be highlighted on the display.
- Press the “▲” or “▼” buttons to calibrate the data value higher or lower from the actual reading.
- Press the “SET” button to confirm the calibration adjustment. The “ ” icon will remain illuminated next to calibrated values.
- The next adjustable data will begin flashing, indicating it is ready to be calibrated. Repeat Steps 1 – 4 to calibrate additional data.
The preference set order is as follows:
OUTDOOR TEMPERATURE
INDOOR TEMPERATURE
INDOOR HUMIDITY
BAROMETRIC PRESSURE (must be set to MANUAL mode; see page 12) After 10 seconds
of inactivity, the display will save the adjustments and exit calibration
mode. Note: Calibrations will be erased if the display is reset or if
batteries are removed and the power adapter is unplugged.
Calibrate Barometric Pressure
The weather station default pressure mode is “AUTO”. In auto mode, the pressure will calibrate itself over a 14-day Learning Mode. Barometric pressure can be manually calibrated:
- Press AND HOLD the “SET” button (located on the back of the display) for at least 10 seconds to enter manual pressure mode.
- The un-calibrated pressure will be displayed. Press AND HOLD the “▲”, “▼”, and “SET” buttons for at least 5 seconds.
- Press and release the “SET” button three times to enter barometric pressure calibration mode.
- Press the “▲” or “▼” buttons to calibrate the pressure higher or lower.
- Press the “SET” button to confirm the calibration adjustment.
Note: The “ ” icon will remain illuminated next to the calibrated value.
After 10 seconds of inactivity, the display will save your adjustments and
exit calibration mode. Note: Calibration will be erased if the display is
reset, set to auto pressure mode, or if the batteries are removed and the
power adapter is unplugged.
To exit manual pressure mode and return to auto pressure mode press and hold
the “SET” button for at least 10 seconds.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGE| Indoor: 1% to 99% RH
WIRELESS RANGE| 165 It / 50 m depending on home construction materials
OPERATING FREQUENCY| 433 MHz
POWER| Display: 5V power adapter
3 x AAA alkaline batteries (optional)
Sensor: 2 x AA alkaline or lithium batteries
DATA REPORTING| Outdoor: 30 second updates
Indoor: 60-second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE : This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur n a particular installation. If his equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increasetheseparationbetween the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment.
Such modifications could void the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
Visit us at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Limited 1-Year Warranty
AcuRite is a wholly-owned subsidiary of Chaney Instrument Company. For
purchases of AcuRite products, AcuRite provides the benefits and services set
forth herein. For purchases of Chaney products, Chaneprovides the benefits and
services set forth herein.
We warrant that all products we manufacture under this warranty are of good
material and workmanship and, when properly installed and operated, will be
free of defects for a
period of one year from the date of purchase.
Any product which, under normal use and service, is proven to breach the
warranty contained herein within ONE YEAR from the date of sale will, upon
examination by us, and at ur sole option, be repaired or replaced by us.
Transportation costs and charges for returned goods shall be paid for by the
purchaser. We hereby disclaim all responsibility for such transportation costs
and charges. This warranty will not be breached, and we will give no credit
for products that have received normal wear and tear not affecting the
functionality of the product, been damaged (including by acts of nature),
tampered, abused, improperly installed, or repaired or altered by others than
our authorized representatives. Remedy for breach of this warranty is limited
to repair or replacement of the defective item(s). If we determine that repair
or replacement is not feasible, we may, at our option, refund the amount of
the original purchase price.
THE ABOVE-DESCRIBED WARRANTY IS THE SOLE WARRANTY FOR THE PRODUCTS AND IS
EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. ALL OTHER
WARRANTIES OTHER THAN THE EXPRESS WARRANTY SET FORTH HEREIN ARE HEREBY
EXPRESSLY DISCLAIMED, INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTY OF
MERCHANTABILITY AND THE IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
We expressly disclaim all liability for special, consequential, or incidental
damages, whether arising in tort or by contract from any breach of this
warranty. Some states do not allow the exclusion or limitation of incidental
or consequential damages, so the above limitation or exclusion may not apply
to you. We further disclaim liability from personal injury relating to our
products to the extent permitted by law. By acceptance of any of our products,
the purchaser assumes all liability for the consequences arising from their
use or misuse. No person, firm or corporation is authorized to bind us to any
other obligation or liability in connection with the sale of our products.
Furthermore, no person, firm, or corporation is authorized to modify or waive
the terms of this warranty unless done in writing and signed by a duly
authorized agent of ours. In no case shall our liability for any claim
relating to our products, your purchase or your use thereof, exceed the
original purchase price paid for the product.
Applicability of Policy
This Return, Refund, and Warranty Policy apply only to purchases made in the
United States and Canada. For purchases made in a country other than the
United States or Canada, please consult the policies applicable to the country
in which you made your purchase. Additionally, this Policy applies only to the
original purchaser of our products. We cannot and do not offer any return,
refund, or warranty services if you buy products used or from resale sites
such as eBay or Craigslist.
Governing Law
This Return, Refund, and Warranty Policy is governed by the laws of the United
States and the State of Wisconsin. Any dispute relating to this Policy shall
be brought exclusively n the federal or state courts having jurisdiction in
Walworth County, Wisconsin; and purchaser consents to jurisdiction within the
State of Wisconsin.
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark
of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and
copyrights are the property of their respective owners. AcuRite uses patented
technology.
Visit www.AcuRite.com/patents for details.
Printed in China
00506 INST 072717
Documents / Resources
|
ACURITE 00484 Weather Forecaster with Temperature and
Humidity
[pdf] Instruction Manual
00484, 00506, 00524, Weather Forecaster with Temperature and Humidity
---|---
References
- AcuRite Weather Monitoring | #1 Weather Station Brand in North America
- Icon Definitions and Terminology | AcuRite
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>