ACURITE 13003 Intelli-Time Alarm Clock Instruction Manual
- June 7, 2024
- Acurite
Table of Contents
Instruction Manual
Intelli-Time® Alarm Clock
model 13003
Questions? Contact Customer Support at
877-221-1252 or visit
www.AcuRite.com
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible product performance, please read this manual in its entirety and retain it for future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Alarm clock
- Instruction Manual
Features & Benefits
1. PM Indicator
2. SNOOZE Button
3. ALARM ON Indicator
4. ALARM SET Button
5. – ADJUST DOWN Button
6. ALARM ON/OFF Switch
7. + ADJUST UP Button| 8. TIME SET Button
9. DST ON/OFF Switch
10. TIME ZONE Selection Switch
11. Intelli-Time ® Battery Compartment
12. RESET Button
Full to factory defaults
---|---
SETUP
Clock Setup
Plug the power cord into a power outlet.
Intelli-Time®Clock
Intelli-Time clock and calendar are pre-programmed to the correct time and
date and update automatically for Daylight Saving Time. All you need to do is
select your time zone using the “TIME ZONE” switch.
Set the Time & Date
Choose the correct time zone (HAST AKST PST MST CST EST AST) using the time
zone selection switch on the back of the clock.
Set Daylight Saving Time ON or OFF using the “DST ON/OFF” switch on the back
of the clock.
Press and hold the “TIME SET” button for 5 seconds to enter SET MODE. Once in
SET MODE the preference you are currently in will blink on the clock.
To adjust the currently selected (flashing) item, press and release the “+
ADJUST UP” or “- ADJUST DOWN” buttons (press and HOLD to fast adjust). To save
your adjustments, press and release the “TIME SET” button to adjust the next
preference. The preference order is as follows:
CLOCK HOUR (Please note PM Indicator light)
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
If you live in an area that observes Daylight Saving Time, DST should be set to ON, even if it is not currently Daylight Saving Time.
You will automatically exit SET MODE if no buttons are pressed for 5 seconds.
Enter SET MODE any time by pressing and holding the “TIME SET” button for 5
seconds.
OPERATION
Using the Alarm Clock
Set the Alarm Time
To set alarm time, press and release the “ALARM SET” button to enter the ALARM
SET MODE.
To adjust the currently selected (flashing) item, press and release the “+
ADJUST UP” or “- ADJUST DOWN” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “ALARM SET“ button to adjust
the next preference. The preference set order is as follows:
ALARM CLOCK HOUR (Please note PM Indicator light)
ALARM CLOCK MINUTE
You will automatically exit ALARM SET MODE if no buttons are pressed for 5
seconds. Enter ALARM SET MODE at any time by pressing the “ALARM SET“ button.
Alarm Clock ON or OFF Function
To turn alarmed on: Slide the “ALARM” switch to “ON”. The Alarm On indicator
will appear on the screen.
To turn alarmed off: Slide the “ALARM” switch to “OFF”. The Alarm On indicator
will disappear from the screen.
Alarm Clock SNOOZE Function
The alarm will sound for 60 minutes before turning off when no button is
pressed. When the alarm is sounding, activate the 8-minute SNOOZE function by
pressing the SNOOZE button on top of the alarm clock. SNOOZE function can be
activated up to 10 times before the alarm will no longer sound.
Troubleshooting
The clock won’t turn on or displays partial numbers| • Reset the unit by
pressing the reset button located on the back of the clock. This will reset
the alarm to the original factory settings. Time and date will need to be
entered after a reset.
---|---
Blinking Colon (dots)| • Blinking of the dots is a way that the seconds are
counted. There is no way to stop the dots from blinking.
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
Clock Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt and moisture. Clean ventilation ports regularly with a
gentle puff of air.
Replace Intelli-Time Clock Battery
Intelli-Time technology is powered by a pre-installed coin-cell battery that
stores the time and date settings. The battery has a shelf life of several
years. Time and date will need to be entered after replacing the Intelli-Time
battery. To replace the Intelli-Time battery:
- Locate the coin cell battery compartment door on the back of the clock. Unscrew and remove the compartment cover.
- Insert 1 x CR2032 coin cell battery into the battery compartment, as shown. Install battery with “+” positive terminal facing OUT.
- Screw in the battery cover.
Specifications
POWER | Power cord (120V) |
---|
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service. For assistance, please have the model number of this product
available and contact us in any of the following ways:
877-221-1252
info@chaney-inst.com
24/7 support at www.AcuRite.com
► Installation Videos
► Instruction Manuals
► Replacement Parts
► Register your Product
► Support User Forum
► Submit Feedback & Ideas
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures to be of good
material and workmanship and to be free of defects when properly installed and
operated for a period of one year from the date of purchase.
We recommend that you visit us at www.AcuRite.com
for the fastest way to register your product. However, product registration
does not eliminate the need to retain your original proof of purchase in order
to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures be of good
material and workmanship and to be free of defects when properly installed and
operated for a period of one year from the date of purchase. Remedy for
breach of this warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is proven to breach
the warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or eplaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges. This warranty will not be breached, and
Chaney will give no credit for products it manufactures which have received
normal wear and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired or altered by
others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties,
express or implied, and all other warranties are hereby expressly disclaimed,
including without limitation the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose. Chaney expressly
disclaims all liability for special, consequential or incidental damages,
whether arising in tort or by contract from any breach of this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation r exclusion may not apply to you. Chaney
further disclaims all liability from personal injury relating to its products
to the extent permitted by law. By acceptance of any of Chaney’s products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm or corporation is authorized to assume for Chaney any
other liability in connection with the sale of its products. Furthermore, no
person, firm or corporation is authorized to modify or waive the terms of this
paragraph, and the preceding paragraph, unless done in writing and signed by a
duly authorized agent of Chaney. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St., Lake Geneva, WI 53147
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
© Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark
of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and
copyrights are the property of their respective owners. AcuRite uses patented
technology.
Visit www.AcuRite.com/patents for details.
Printed in China
00606 INST 033014
Documents / Resources
|
ACURITE 13003 Intelli-Time Alarm
Clock
[pdf] Instruction Manual
13003, Intelli-Time Alarm Clock
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>