Instruction Manual
Weather Center
model 00589
Questions? Contact Customer Support at
877-221-1252 or visit
www.AcuRite.com.
SAVE THIS MANUAL FOR FUTURE REFERENCE.
Congratulations on your new AcuRite product. To ensure the best possible
product performance, please read this manual in its entirety and retain it for
future reference.
Unpacking Instructions
Remove the protective film that is applied to the LCD screen prior to using this product. Locate the tab and peel it off to remove it.
Package Contents
- Display unit with tabletop stand
- 3-in-1 sensor
- Sensor mounting bracket
- Mounting hardware
- Power adapter
- Instruction Manual
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection
www.AcuRite.com
Features & Benefits
3-in-1 SENSOR
-
Temperature & Humidity Sensors
(internal) -
Release Lever for Battery Access
-
Mounting Point
-
Wind Speed Anemometer
-
Mounting Hardware
Includes anchors and screws. Qty| Diameter| Length
---|---|---
4| #4| 1”
1| #6 or #8| 1/4” or 3/8” -
Mounting Bracket
-
A-B-C Switch
(not shown) ID code that must match display’s A-B-C switch to ensure units synchronize.
Display Unit
|
---|---
DISPLAY UNIT
-
Current Outdoor Temperature
The arrow icon indicates direction temperature is trending. -
Sensor Low Battery Indicator
-
Average Wind Speed
Average of all speeds over the last 30 minutes or calibrated 30-minute interval. -
Backlight Button
-
Current Wind Speed
-
Wind Gust Icon
-
Peak Wind Speed Highest speed
from last 30 minutes or calibrated 30-minute interval. -
Current Indoor Temperature
The arrow icon indicates direction temperature is trending. -
Display Low Battery Indicator
-
Current Indoor Humidity
The arrow icon indicates direction humidity is trending. -
Clock
-
Date
-
REPLAY and LIVE Icons
REPLAY indicates historical data is being displayed. The LIVE icon is shown while exiting the REPLAY function. -
12 to 24 Hour Weather Forecast
Self-Calibrating Forecasting pulls data from the outdoor sensor to generate your personal forecast. -
Multi-Variable History Chart
Displays the past 12 hours of data for pressure, temperature, and humidity. -
REPLAY Button
For displaying historical data. -
+ Button For setup preferences.
-
SET Button For setup preferences.
-
_ Button For setup preferences.
-
SELECT Button
Press to change the Weather Select (#23) category is displayed. -
Barometric Pressure
The arrow icon indicates direction pressure is trending. -
Learning Mode Icon
Disappears after weather forecast self-calibration is complete. -
Weather Select
Displays heat index, dew point or wind chill, daily, monthly, all-time high & low records indoor/outdoor temperatures and humidity and high for wind speed. -
AUTO DIM Indicator
-
The current Outdoor Humidity
The arrow icon indicates direction temperature is trending. -
Low Wind Speed
Lowest speed from past 30 minutes or calibrated 30-minute interval. -
Outdoor Sensor Signal Strength
BACK OF DISPLAY UNIT -
Integrated Hang Hole
For easy wall mounting -
Plug-in for Power Adapter
-
Battery Compartment
-
A-B-C Switch
ID code that must match sensor’s A-B-C switch to ensure units synchronize. -
CLEAR RECORD/RESET Button
Press to clear record currently being viewed. Press and HOLD for the full reset to factory defaults. -
Battery Compartment Cover
-
Power adapter
SETUP
3-IN-1 Sensor Setup
-
Set the A-B-C Switch
The A-B-C switch is located inside the battery compartment. It can be set to A, B, or C. However, you must select the same letter choices for both the sensor and the display unit ·in order for the units to synchronize. -
Install or Replace Batteries
AcuRite recommends high-quality alkaline or lithium batteries for the best product performance. Heavy duty or rechargeable batteries are not recommended.
The 3-in-1 sensor requires lithium batteries in low-temperature conditions. Cold temperatures can cause alkaline batteries to function improperly. Use lithium batteries in the 3-in-1 sensor for temperatures below -4ºF / -20ºC.
1. Press the release lever and pull off the lower housing of the sensor.
2. Remove the battery compartment cover. Take note of the A-B-C switch setting inside the battery compartment.
3. Insert 4 x AA batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
4. Replace the battery cover and lower housing of the sensor.
Display Unit Setup
-
Set the A-B-C Switch
Locate the A-B-C switch inside the battery compartment. Set the A-B-C switch to A, B, or C. You must select the same letter choices for both the display unit and the sensor in order for the units to synchronize. -
Install or Replace Batteries
1. Remove the battery compartment cover.
2. Insert 6 x AA alkaline batteries into the battery compartment, as shown. Follow the polarity (+/-) diagram in the battery compartment.
3. Replace the battery cover. -
Plug Power Adapter into Electric Outlet
IMPORTANT: Batteries are a backup power source to preserve records in the
event of a power outage. The power adapter is recommended as the primary power
source to enjoy the full functionality of this product.
PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENTALLY SAFE WAY
AND IN ACCORDANCE WITH YOUR LOCAL LAWS AND REGULATIONS.
BATTERY SAFETY: Clean the battery contacts and also those of the device
prior to battery installation. Remove batteries from equipment that is not to
be used for an extended period of time. Follow the polarity (+/-) diagram in
the battery compartment. Promptly remove dead batteries from the device.
Dispose of used batteries properly. Only batteries of the same or equivalent
type as recommended are to be used. DO NOT incinerate used batteries. DO NOT
dispose of batteries in fire, as batteries may explode or leak. DO NOT mix old
and new batteries or types of batteries (alkaline/standard). DO NOT use
rechargeable batteries. DO NOT recharge non-rechargeable batteries. DO NOT
short-circuit the supply terminals.
Set the Time, Date & Units
Press the “SET” button, located on the front of the display unit, to enter SET
MODE. Once in set mode, the preference you are currently setting will blink on
the display.
To adjust the currently selected (flashing) item, press and release the “+” or
“_” buttons (press and HOLD to fast adjust).
To save your adjustments, press and release the “SET” button again to adjust
the next preference. The preference set order is as follows:
CLOCK HOUR
CLOCK MINUTE
CALENDAR MONTH
CALENDAR DATE
CALENDAR YEAR
TEMPERATURE UNITS (ºF or ºC)
WIND UNITS (MPH or KM/H)
PRESSURE UNITS (inHg or hPa)
You will automatically exit SET MODE if no buttons are pressed for 10 seconds.
Enter setup mode at any time by pressing the “SET” button.
Display Backlight Settings
This weather station’s color display features three different lighting
settings: High (100%) brightness, Medium (60%) brightness, and Low (30%)
brightness
Using battery power alone, the backlight is available momentarily for
10seconds by pressing the “ ” button.
When the display is powered with the power adapter, the backlight remains on
at 100% brightness. Press the “ ” button once to dim to 60% brightness; press
again to dim to 30%, press a 3rd time to enter “AUTO DIM” mode. AUTO DIM
appears above time and date.
AUTO DIM MODE: Automatically adjusts display brightness based on time of day & year.
MARCH 11- NOVEMBER 4| 6:00 a.m. – 9:00 p.m. = 100% brightness
9:01 p.m. – 5:59 a.m.= 30% brightness
NOVEMBER 5 – MARCH 10| 7:30 a.m. – 7:00 p.m.= 100% brightness
7:01 p.m. – 7:29 a.m. = 30% brightness
Placement for Maximum Accuracy
AcuRite sensors are sensitive to surrounding environmental conditions. Proper
placement of both the display unit and the sensor is critical to the accuracy
and performance of this product.
Display Unit Placement
Place the display unit in a dry area free of dirt and dust. To ensure accurate
temperature measurement, place out of direct sunlight and away from heat
sources or vents. The display unit stands upright for tabletop use or is wall-
mountable.
3-in-1 Sensor Placement
The
3-in-1 sensor is designed to remain outdoors all year long. Choose an open
location with no obstructions above or around the sensor for the most accurate
measurements.
Important Placement Guidelines
The display unit and sensor must be within 330 feet (100 m) of each other.
MAXIMIZE WIRELESS RANGE
Place units away from large metallic items, thick walls, metal surfaces, or
other objects that may limit wireless communication.
PREVENT WIRELESS INTERFERENCE
Place both units at least 3 feet (.9 m) away from electronic devices (TV,
computer, microwave, radio, etc.).
LOCATE AWAY FROM HEAT SOURCES
Position sensor away from heaters, air conditioners, chimneys, exhaust vents,
asphalt, and concrete (surfaces that radiate heat).
LOCATE AWAY FROM HUMIDITY SOURCES
Avoid installing the sensor near pools, spas, or other bodies of water. Water
sources may impact humidity accuracy.
LOCATE AWAY FROM SPRINKLER HEADS
DO NOT install the sensor where it will be sprayed by a sprinkler system. This
may force water inside the sensor.
LOCATE AWAY FROM WIND OBSTRUCTIONS DO NOT mount the sensor with
obstructions around it. Consider a location that is a wide-open area, with few
structures around to ensure accurate wind speed measurement.
Visit us online to view installation photos and video, or learn more about
AcuRite technology: www.AcuRite.com/3in1
http://www.acurite.com/3in1?utm_source=00608-00607&utm_medium=qr&utm_campaign=Instructions
3-in-1 Sensor Installation Guidelines
INSTALLATION HEIGHT Mount the sensor at least 5 feet (1.5 meters) off the
ground (higher is better for wind measurement) in an open area. Secure to a
fence post, 2″x4″ wood, 3/4″ pole, etc. (not included)
LEVEL INSTALLATION Use a bubble level (not included) to ensure level
installation for accurate wind measurement.
Top or Side Mount
- Insert the mounting base into the hole on the bottom of the sensor.
- Use one of the screws included in the hardware bag to fasten the lower sensor housing to the mounting base.
- Fasten mounting base to a post or railing using 2 screws.
Pole Mount
- Insert pole (we recommend 3/4″ schedule 40 PVC / 25.8 mm O.D., not included) or similar item all the way into the hole on the bottom of the sensor. Note: Mounting base is not used.
- Use one of the screws included in the hardware bag to fasten the lower sensor housing securely to the pole.
The 3-in-1 sensor is now ready to use.
Clear Data Collected During Installation
When the installation is complete, clear erroneous data from the display unit
by pressing the “CLEAR RECORD/RESET” button for each category, on the back of
the display inside the battery compartment.
Basic Setup is Complete
The 3-in-1 sensor will now synchronize with the display unit. It may take a
few minutes for synchronization to complete. If both or one of the units
appears to be functioning improperly, please refer to the troubleshooting
section.
OPERATION
Using The Weather Center
Learning Mode
Self-Calibrating Forecasting uses a unique algorithm to analyze changes in
pressure over a time period (called Learning Mode) to determine your altitude.
After 14 days, the Learning Mode icon disappears from the display screen. At
this point, the self-calibrated pressure is tuned in to your location and the
unit is ready for superior weather prediction.
Weather Forecast
AcuRite’s patented Self-Calibrating Forecasting provides your personal
forecast of weather conditions for the next 12 to 24 hours by collecting data
from the sensor in your backyard. It generates a forecast with pinpoint
accuracy – personalized for your exact location.
View the complete list of icons at www.AcuRite.com/acurite- icons
Multi-Variable History Chart
The multi-variable history chart lets you monitor the change in conditions
over the past 12 hour time period (-12, -6, -3, -2, -1, 0). The chart
automatically toggles between barometric pressure, outdoor temperature, and
outdoor humidity readings.
Wind Speed
The Wind Speed area of the display features the CURRENT speed, as well as the
LOW, AVERAGE, and PEAK wind speeds. PEAK, AVERAGE, and LOW wind speeds are
based on the past 30-minute time frame by default. The time frame can be
adjusted during the calibration process (page 15).
Barometric Pressure
Subtle variations in barometric pressure greatly impact the weather. This
weather center displays the current pressure with an arrow icon to indicate
the direction the pressure is trending (FALLING, STEADY, or RISING). The
multi-variable history chart lets you monitor the change in pressure over
time.
Weather Select
Weather Select displays data including wind chill, dew point, heat index, as
well as 24-hour change, and high/low records for outdoor/indoor temperatures,
humidity, and wind speed. To change the “Weather Select” category shown, press
the “SELECT” button on the front of the display. When outdoor/indoor
temperature or humidity is chosen, the display cycles through the category’s
records in this order:
24 Hour Change (the amount the data has changed since 24 hours ago)
Today’s HIGH
Today’s LOW
Month’s HIGH
Month’s LOW
All Time HIGH
All Time LOW
When Wind Speed is chosen, the display cycles through the following records:
Today’s HIGH
Month’s HIGH
All Time HIGH
To clear a record, view one of the values listed above and press the “CLEAR
RECORD/RESET” button, located on the back of the unit in the battery
compartment. Dashes display to confirm the record has been cleared.
REPLAY Historical Data
This weather station stores historical data that can be viewed in Replay Mode.
Data is recorded for the past 48 hours in 30-minute intervals (on the hour and
half hour). Historical data is shown with a time and date stamp.
Press the “REPLAY” button to enter Replay Mode. The REPLAY icon and options
will be shown on the display below the time.
REPLAY MODE OPTIONS:
-
Press the “SET” ( ) b>utton to view 48-hour historical data. First, data is shown
that was recorded 48 hours ago, and then the display cycles through the historical data in 30-minute intervals up to the current time. To exit Replay Mode and view live data, press the “REPLAY” button -
Press the “-” ( ) button to view historical data in 30-minute intervals previous to the current “LIVE” data.
-
While viewing historical data, press the “+” ( ) button to advance the data shown by a 30-minute interval.
You will automatically exit Replay Mode if no buttons are pressed for 10 seconds. To manually exit Replay Mode at any time, press the “REPLAY” button. The display may show or flash the “LIVE” icon to confirm you are exiting Replay Mode and returning to the current (“LIVE”) data view.
Troubleshooting
Problem|
Possible Solution
---|---
No outdoor sensor reception|
-
Relocate the display unit and/or the 3-in-1 sensor. The units must be within 330 ft (100 m) of each other.
-
Make sure both units are placed at least 3 feet (.9 m)
away from electronics that may interfere with wireless communication (such as TVs, microwaves, computers, etc). Use standard alkaline batteries (or lithium batteries in the sensor when the temperature is below -4ºF/-20ºC). Do not use heavy-duty or rechargeable batteries. NOTE: It may take up to 20 minutes for the display unit and sensor to synchronize after batteries are replaced. -
Synchronize the units:
1. Bring both the sensor and display unit indoors and remove at least one battery from each.
2. Make sure the A-B-C switch on both units matches. Reinstall the battery in the outdoor sensor.
3. Reinstall the battery into the display unit.
4. Let the units sit within a couple of feet of each other for about 20 minutes to gain a strong connection.
Outdoor temperature is flashing or showing dashes| Flashing of the outdoor temperature may be an indication of wireless interference:
- Make sure the A-B-C switch in the battery compartments of both the display unit and sensor are switched to the same letter. You may choose A, B, or C; but both units must match to sync up. Sometimes changing to a different channel can help.
Inaccurate forecast|
- The Weather Forecast icon predicts conditions for the next 12 to 24 hours, not current conditions.
- Has the Learning Mode icon disappeared from the display unit? Learning Mode must complete before forecast and pressure will be accurate.
- Allow the unit to run continuously for 33 days. Battery removal or resetting the display unit will restart Learning Mode. After 14 days, the forecast should be fairly accurate, however, Learning Mode calibrates for a total of 33 days.
Inaccurate temperature
or humidity|
- Make sure both the display unit and 3-in-1 sensor are placed away from any heat sources or vents (see page 9).
- Make sure both units are positioned away from moisture sources (see page 9).
- Make sure the 3-in-1 sensor is mounted at least 5 ft off of the ground.
- Calibrate indoor and outdoor temperature and humidity(see page 15).
Inaccurate wind
readings|
- Make sure both the display unit and 3-in-1 sensor are placed away from any heat sources or vents (see page 9).
- Make sure both units are positioned away from moisture sources (see page 9).
- Make sure the 3-in-1 sensor is mounted at least 5 ft off of the ground.
- Calibrate indoor and outdoor temperature and humidity (see page 15).
Inaccurate wind readings|
- What is wind reading being compared to? Pro weather stations are typically mounted at 30 ft high or more. Make sure to compare data using a sensor positioned at the same mounting height.
- Check the location of the sensor. Ensure it’s mounted a minimum of 5 ft in the air with no obstructions around it (within several feet).
- Ensure wind cups are spinning freely. If they hesitate or stop try lubricating with graphite powder or spray lubricant.
Display screen not working|
- Check that the batteries are installed correctly. Batteries may need to be replaced.
- Reset the display by pressing and HOLDING the “CLEAR RECORD/RESET” button, located on the back of the display unit in the battery compartment. The date and time will need to be entered after a reset.
If your AcuRite product does not operate properly after trying the troubleshooting steps, visit www.AcuRite.com or call 877-221-1252 for assistance.
Care & Maintenance
Display Unit Care
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives. Keep
away from dust, dirt, and moisture. Clean ventilation ports regularly with a
gentle puff of air.
3-in-1 Sensor Care
Clean the Sensor
Clean with a soft, damp cloth. Do not use caustic cleaners or abrasives.
Insect Prevention
Insects may cause obstructions and interrupt data by nesting in or on the
3-in-1 sensor. To limit this problem, spray sensor housing with a household
insect repellent.
Note: Insect repellent should not be sprayed on the internal components
or into the sensor. Consult insect repellent instructions prior to use.
Snow & Freezing Weather
The 3-in-1 sensor will not be damaged by freezing conditions.
Clean the Wind Anemometer
Remove foreign matter from the outside of the sensor for free movement of the
wind anemometer. If needed, use a small amount of spray lubricant, clear
silicone, or graphite powder on the anemometer for improved movement. Note:
Spray lubricant, clear silicone, or graphite powder should not be sprayed on
the internal components or into the sensor.
Calibration
The indoor/outdoor temperature and humidity readings, wind speed interval, and barometric pressure can be calibrated on the display unit to improve accuracy. Calibration can improve accuracy when sensor placement or environmental factors impact the data accuracy.
-
To access calibration mode, press AND HOLD the “-“, “SET” and “+” buttons simultaneously
for at least 5 seconds. -
To adjust the currently selected (flashing) item, press and release the “-” or “+” buttons to
calibrate the data value higher or lower from the actual reading. -
To save your adjustments, press and release the “ button to adjust the next preference.
The ” ” icon will remain illuminated next to calibrated values.
The preference set order is as follows:
OUTDOOR TEMPERATURE
OUTDOOR HUMIDITY
INDOOR TEMPERATURE
INDOOR HUMIDITY WIND SPEED INTERVAL (30, 60, 90, 120, 150 or 180 minutes)
BAROMETRIC PRESSURE (must be set to MANUAL mode to calibrate)
To change from AUTO to MANUAL pressure mode and vice versa, press AND HOLD the “SET” button for at least 10 seconds. The display indicates the current pressure mode selected, “AUTO” or “MANUAL”. After 10 seconds of inactivity, the display will save the adjustments and exit calibration mode. Note: Calibration preferences will be erased if the display is reset or if batteries are removed and the power adapter is unplugged.
Specifications
TEMPERATURE RANGE | Outdoor: -40°F to 158°F; -40°C to 70°C |
---|
Indoor: 32°F to 122°F; 0°C to 50°C
HUMIDITY RANGE| Outdoor: 1% to 99%
Indoor: 1% to 99%
WIND SPEED| 0 to 99 mph; 0 to 159 kph
WIRELESS RANGE| 330 ft / 100 m depending on home construction materials
OPERATING FREQUENCY| 433 MHz
POWER| Display: 5V, 100mA power adapter 6 x AA alkaline batteries
Sensor: 4 x AA alkaline or lithium batteries
DATA REPORTING| Wind Speed: 18-second updates
Outdoor temperature & humidity: 18 second updates
Indoor temperature & humidity: 60 second updates
FCC Information
This device complies with part 15 of FCC rules. Operation is subject to the following two conditions:
- This device may NOT cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING: Changes or modifications to this unit not expressly approved by
the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference received, including interference that may cause undesired operation of the device.
Customer Support
AcuRite customer support is committed to providing you with best-in-class
service.
For assistance , please have the model number of this product available
and contact us in any of the following ways:
877-221-1252
info@chaney-inst.com
24/7 support at www.AcuRite.com
- Instruction Manuals
- Support User Forum
- Replacement Parts
- Submit Feedback & Ideas
IMPORTANT
PRODUCT MUST BE REGISTERED TO RECEIVE WARRANTY SERVICE
PRODUCT REGISTRATION
Register online to receive 1-year warranty protection
www.AcuRite.com
Limited One Year Warranty
At AcuRite, we proudly uphold our commitment to quality technology. Chaney
Instrument Co. warrants that all products it manufactures be of good material
and workmanship, and to be free of defects when properly installed and
operated for a period of one year from the date of purchase.
We recommend that you visit us atwww.AcuRite.com
for the fastest way to register your product. However, product registration
does not eliminate the need to retain your original proof of purchase in order
to obtain warranty benefits.
Chaney Instrument Co. warrants that all products it manufactures be of good
material and workmanship, and to be free of defects when properly installed
and operated for a period of one year from the date of purchase. Remedy for
breach of this warranty is limited to repair or replacement of the defective
item(s). Any product which, under normal use and service, is proven to breach
the warranty contained herein within ONE YEAR from the date of sale will, upon
examination by Chaney, and at its sole option, be repaired or replaced by
Chaney. Transportation costs and charges for returned goods shall be paid for
by the purchaser. Chaney hereby disclaims all responsibility for such
transportation costs and charges. This warranty will not be breached, and
Chaney will give no credit for products it manufactures which have received
normal wear and tear, been damaged (including by acts of nature), tampered,
abused, improperly installed, damaged in shipping, or repaired or altered by
others than authorized representatives of Chaney.
The above-described warranty is expressly in lieu of all other warranties,
express or implied, and all other warranties are hereby expressly disclaimed,
including without limitation the implied warranty of merchantability and the
implied warranty of fitness for a particular purpose. Chaney expressly
disclaims all liability for special, consequential, or incidental damages,
whether arising in tort or by contract from any breach of this warranty. Some
states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you. Chaney
further disclaims all liability from personal injury relating to its products
to the extent permitted by law. By acceptance of any of Chaney’s products, the
purchaser assumes all liability for the consequences arising from their use or
misuse. No person, firm, or corporation is authorized to assume for Chaney any
other liability in connection with the sale of its products. Furthermore, no
person, firm, or corporation is authorized to modify or waive the terms of
this paragraph, and the preceding paragraph, unless done in writing and signed
by a duly authorized agent of Chaney. This warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
For in-warranty claims: Chaney Instrument Co.
965 Wells St. | Lake Geneva, WI 53147
It’s more than accurate, it’s
AcuRite offers an extensive assortment of precision instruments,
designed to provide you with information you can depend on to
Plan your day with confidence™.
www.AcuRite.com
©Chaney Instrument Co. All rights reserved.
AcuRite is a registered trademark of the Chaney Instrument Co.,
Lake Geneva, WI 53147. All other trademarks and copyrights are the property of
their respective owners.
AcuRite uses patented technology.
Visit www.AcuRite.com/patents for details.