ACURITE 5N1WCBSA 5-in-1 Sensor Bearing Kit Installation Guide
- June 7, 2024
- Acurite
Table of Contents
5-in-1 Sensor Bearing Kit
5N1WCBSA
http://www.acurite.com/replacement-5-in-1-sensor-assembly-wind-cups-
5n1wcbsa.html?utm_source=5N1WCBSA&utm_medium=qrcode&utm_campaign=Instructions
If you’re experiencing problems with your 5-in-l sensor such as no wind-speed
readings or lower than expected wind speed readings and your 5-in-l sensor is
mounted properly, the bearings for the anemometer may be worn and will require
replacement. Your AcuRite 5-in-l sensor features a modular design that allows
for the replacement of certain assemblies should they wear or cease to
function. Please take care when handling the 5-in-l sensor components as the
electronic components inside are sensitive.
NOTE: You will need to remove your existing 5-in-l sensor from its
mounting location to replace the wind speed (anemometer) bearing sub-assembly.
WHAT YOU NEED:
- Your 5-in-1 Sensor
- New Bearing Assembly
- Phillips Head Screwdriver
- Remove four LONG screws and separate the upper white portion and lower gray portions of the sensor. Keep the screws for re-assembly.
- Set aside the lower gray portion for reassembly later.
- Turn the upper white portion over and remove the 4 SHORT screws near the fan assembly. Keep the screws for reassembly.
- Gently remove the old upper wind speed and solar assembly from rain housing and discard.
- Place new wind speed/solar assembly and line up the screw holes with the upper rain housing.
- Turn the upper white portion over and re-install the 4 SHORT screws and tighten them by hand.69
- Reinstall four LONG screws to join the upper white portions and lower gray portions of the sensor.