PRESTIGE PE1BZ APSSECRS Security and Remote Start User Guide

June 6, 2024
PRESTIGE

PRESTIGE logo

APSSECRS
Security and Remote Start
Quick Installation Guide
For Complete Installation Guide and Technical Support
Please visit:www.voxxuniversity.com
Or Call
1-800-225-6074

REV. B
2020 Voxx Electronics. All Rights Reserved.

Notifications
Alarm
When the alarm is triggered the system will provide feedback to the user. Upon disarm, the system will beep 4x and flash the LED to indicate the Alarm Trigger Zone.

1 Shock
2 Trunk / Hood
3 Door

If the remote start fails to start the vehicle, the system will flash the vehicle parking lights to indicate the cause.

1 Runme Expired
2 Remote Shutdown
3 Brake On
4 Manual Mode
5 Hood Open
6 Low / No Tach
7 Tach Programming
8 High Tach

Chirp Delete
System ARM/DISARM chirps can be toggled ON or OFF without entering the Feature Bank programming.

  1. Turn the ignition key ON/OFF.
  2.  Press and release the valet button three (3) times.

The system will respond with one (1) chirp for ON and two (2) Chirps for OFF. This feature will not affect alarm trigger or programming.
User Programmable LED
System LED notifications can be turned ON or OFF without entering Feature Bank programming.

  1. Turn the ignition key ON/OFF, ON/OFF.
  2. Press and hold valet button for five (5) seconds.

The LED will flash one (1) time for ON, two (2) times for OFF. This feature will not affect LED flash during programming.

Remote Programming

The APSSECRS does not include an RF remote kit. The RF remote kit Includes two (2) remotes, one (1) antenna, and one (1) cable. When added, remotes must be programmed to the system. Remote Programming is located in Feature Bank 1. To enter Remote Auto Programming:

  1. Turn the ignition key to ON.
  2. Press and release the valet button three (3) times. The system will beep and flash the parking lights one (1) time.

Press the lock button on each remote. The system will beep one  (1) time to indicate the remote has been programmed. If programming one (1) button remotes press the Start button. Only primary remote functions are auto-programmed. This Includes Lock, Unlock, and Trunk/Start.
If using AUX output control, you must manually program the AUX output channels to the remote. Please see the complete installation guide for manual remote programming
instruction.
Note: If programming 2-Way remotes, wait for the remote to beep before programming additional remotes. This beep is confirmation that a 2-Way response has been received
from the main module.

Feature Programming

The APSSECRS Feature Banks can be programmed by using the valet button and remote.
To enter Feature Bank programming:

  1. Turn the ignition key to ON.
  2.  Press and release the valet button three (3) times. The system will beep and flashlights one (1) time for Feature Bank 1, Remote Programming.
  3. Cycle ignition key OFF/ON. The system will beep and flashlights two (2) times for Feature Bank 2.
  4. Press valet button to cycle features. LED will flash to display the feature number.
  5. Press lock button to cycle options. The system will beep to indicate option number.
  6. Cycle ignition key OFF/ON. The system will beep and flashlights three (3) times for Feature Bank 3.
  7. Press valet button to cycle features. LED will flash to display the feature number.
  8. Press lock to cycle options. The system will beep to indicate the option Number.

Tach Programming

The installer must manually configure the Engine Confirmation method in Feature Bank 3, Feature 5. The default method is “Tach”. When using the default “Tach” method,  the vehicle tach rate must be programmed. To enter tach rate programming:

  1. Turn the ignition key ON.
  2. Press and release the valet button three (3) times.
  3. Turn the ignition key OFF.
  4. Press and hold valet button.
  5. While holding valet button, start the engine using the key.
  6. Hold the valet button for approximately ten (10) seconds. If connected to the vehicle Tach source, the system will flash the parking lights one (1) time every second.
  7. Release the valet button. The system will turn on the parking lights for two (2) seconds to indicate the tach rate is programmed.

The tach rate can also be programmed without the use of a valet button. This is helpful when using the OEM remote of CarLink system to control this module. To program the  tach rate without a valet button:

  1. Turn the ignition key to the ON position and start the vehicle’s engine.
  2. Wait for Engine RPM to lower to a normal idle.
  3. Press and hold the vehicle’s brake pedal.
  4. Press the LOCK button on the OEM remote or the Carlin App.

Note: Programming tach signal via OEM or Telematics control is only available on Firmware v1.47 or Higher.

Data Protocol Selection

The default data port protocol of this model is ADS (iDatalink 2-Way). This model is capable of detecting the correct data port protocol (ADS or DBI) and automatically configuring Feature Bank 2; Feature 18. To initialize the detection procedure:

  1. Press and hold the valet button.
  2. Cycle the vehicle’s Ignition ON/OFF two (2) times.
  3. Release the valet button.

The system will automatically detect and set the correct data port protocol, ADS or DBI. Note: This feature is only available on module firmware v2.0 or higher.
The Feature Banks below can also be programmed using the FlashLogic Weblink or Weblink Mobile.

Feature Bank 2 Options
1 Chirp 2 Chirp
Features 1
5COms UL DBL L, DBL UL
2 Ignition Lock
3 Ignition Unlock
4 Exterior Illumination
5 Auto Relock
6 Auto Arrning/ Locking
7 Notification Sound
8 Horn Timing
9 Valet Override Method
10 Driver Priority Unlock
11 Silent Choice
12 Security Profile
OEM RS
13 Door Trigger Input
14 Park Light / Trunk Swap
15 Data Port Protocol
16 Dome Light Delay Timer
17 Alarm Trigger Legnth
Feature Bank 3 Options
1 Chirp 2 Chirp

Features

| 1| Defrost Output| Pulsed| 10min| RS Runtime| | |
2| RS Start Notification| ON| OFF| | | |
3| RS Runtime| 15min| 20min| 45min| 60min| 5min| 10min
4| RS Parking Lights| Steady| Flashing| | | |
5| Engine Confirmation| Tach| Voltage| Data| Hybrid| |
6| Voltage Level| >0.5v 84 Start| <0.5v B4 Start| | | |
7| Ignition 2 Output| Ignition| Accessory| Start| | |
8| Ignition 3 Output| Ignition| Accessory| Start| | |
9| Accessory Output| Accessory| Ignition| Start| | |
10| Transmission| Auto| Manual| | | |
11| Max Crank Time| 0.8sec| 1.0sec| 1.5sec| 2.0sec| 3. Osec| 4. Osec
12| Diesel Delay| OFF| Diesel 5| Diesel 10| Diesel 15| Diesel 20| Diesel 30
13| Temperature Start| OFF| 14 F| SF| OF| -4 F| -14 F
14| Crank Duration| Averaging| Preset| | | |
15| RS Shock Override| Shunt until Clear| Shunt RS Cycle| Shunt From TX| | |
16| Turbo Timer| OFF| 3min| 5min| 10min| |
17| Start Activation| Two Press| One-Press| Three Press| | |
18| RS Lock Function| No Change| UL Before L After| UL Before Start| Lock After Start| |
19| Factory Disarm Output| Single Pulse| Double Pulse| 350ms| 500ms| 800ms| Same As Bank 2, Fl
20| Additional Unlock Pulse| No Pulse| IGN, ACC, GWR| IGN,ACC,GWR,PASD| | |

Dome Delay Programming

This system can be programmed to ignore the vehicle’s theater dimming dome light. This feature will be used when connecting the door trigger input to the dome light circuit for the alarm trigger.
Start with all doors closed and the vehicle dome light off.

  1. Press Lock, Unlock, Lock, Unlock, Lock, Unlock, Lock. LED will light solid.
  2. Open and close the driver’s door.

The system will monitor the dome light circuit. When the dome light turns off the system will set the delay time and add an additional two (2) seconds.
Dome Delay Reset

  1. Key ON/OFF, ON/OFF, ON/OFF.
  2. Press and hold valet button for five (5) seconds.

The system will beep one (1) time to indicate reset is complete.

Programmable Input Control

Programmable Input Control allows any PIC be configured to one of the options listed below. This feature is accessible via FlashLogic Weblink or Weblink Mobile.

Door Trigger Full Shock Trigger
Trunk Trigger Parking Brake
Hood Trigger Brake
N.C. Door Trigger External Start Activation
Pre-Warn Shock Trigger Diesel Glow Plug

Negative Output Control (NOC)

Negative output control allows any NOC to be programmed for any one of the options

Lock Ground While Armed
Unlock Ground While Disarmed
2nd Unlock Domelight
Trunk Headlight
Remote Start Status Defrost
Ignition LED
Factory Disarm Ch. 4 AUX
Factory Arm Ch. 5 AUX
Accessory Ch. 6 AUX
Pulse During Crank Ch. 7 AUX

Pulse Atier Shutdown

AUX Output Control

Any AUX output can be configured using the AUX Control Menu. This feature is only accessible via FlashLogic Weblink or Weblink Mobile.

APSSECRS
Security and Remote Start
System Layout
Important Update

The default Data Port Protocol of this system is ADS. If using a FLCAN or other external integration modules be sure to choose iDatalink 2-Way when flashing.
This system will also support DBI Protocol. This will require programming Feature Bank 2, Feature 15 to DBI.

PRESTIGE PE1BZ APSSECRS Security and Remote Start

Shock 4 Red Battery 12V (+)
3 Black Data TX
2 Blue Warn Away
1 Green Full Trigger

Replacement Part #4120459

22 Pin Input/Output 22 Green Unlock Output (-) (NOC 11)
21 Dk. Blue Trunk Output (-) (NOC 9)
20 Red Lock Output (-) (NOC 10)
19 Green/Lt. Blue Ch. 4 AUX Output (-) (NOC 8)
18 Black/White Horn Output (-)
17 Lt. Blue/Green Ch. 5 AUX Output (-) (NOC 7)
16 Red/Black 2nd Unlock Output (-) (NOC 12)
15 Black/Lt. Green Factory Arm Output (-) NOC 6)
14 Brown/Black Brake Input (+) (PIC 6)
13 Black/Blue Factory Disarm Output (-) (NOC 5)
12 Dk. Blue/Black External Activation Input (-) (PIC 5)
11 Black/Red Pulse After Shutdown Output (-) (NOC 4)
10 Orange/Black Parking Brake Input (-) (PIC 4)
9 Black/Yellow Pulse During Crank Output (-) (NOC 3)
8 Green/Yellow Diesel Glow Plug Input (4-) (PIC 3)
7 Green/White HomeLight Output (-) (NOC 2)
6 Purple/Brown Door Trigger Input (- / +)
5 Lt. Blue Remote Start Status Output (-) (NOC 1)
4 Green/Orange Tach Input (-)
3 Gray/Black Hood Input (-) (PIC 2)
2 Lt. Green Trunk Trigger Input (-) (PIC 1)
1 Orange Starter Kill Relay / Anti-Grind Output (-)

Replacement Part #4120457

Weblink 4 Red Battery 12V (+)
3 Black Ground (-)
2 Blue Data TX
1 White Data RX

Not Included

This Harness is included with the FLCART.
For Wire Information and Diagram Please Refer to Vehicle Specific
FlashLogic Install Guide.
Visit www.FlashLogic.com for More Information.
Not Included

Compatible RF Kits

PE1BZ| PE2LEDZ
PE1BZLR| PE2LCDZ
PE1BTWZ| PE1M2LEDZ
PE5BZ| PE1M2LCDZ

For Complete Installation Guide and Technical Support Visit www.voxxuniversity.com. Or Call 1-800-225-6074

REV. B
2020 Voxx Electronics. All Rights Reserved.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

PRESTIGE User Manuals

Related Manuals