Honeywell RTH2300B1012 Programmable Thermostat Owner’s Manual
- June 6, 2024
- Honeywell
Table of Contents
- Congratulations, you’re done!
- Advanced Installation
- Thermostat controls
- Program Schedule
- To adjust program schedules (RTH2300)
- To adjust program schedules (RTH221)
- Program schedule override (temporary)
- Program schedule override (permanent)
- Built-in compressor protection
- Battery replacement
- Troubleshooting
- 1-year limited warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
RTH2300/RTH221
Series
Programmable Thermostat
Owner’s Manual
RTH2300B1012
Read before installing
For help please visit resideo.com
Identify System Type
This thermostat is compatible with the following systems:
- Gas, oil or electric furnace
- Central air conditioner
- Hot water system with or without pump
- Millivolt system
- Central heating and cooling system
- Heat pump without auxiliary/backup heat
Do you need assistance? We are here to help.
Call 1-800-468-1502 for wiring
assistance before returning the thermostat to the store.
This thermostat cannot be used on heat pumps with backup heat or on
multistage systems.
ATTENTION: MERCURY RECYCLING NOTICE
This product does not contain mercury. However, this product may replace a
product that contains mercury. Mercury and products containing mercury should
not be discarded in household trash.
For more information on how and where to properly recycle a thermostat
containing mercury in the United States, please refer to the Thermostat
Recycling Corporation at www.thermostat-recycle.org.
For mercury thermostat recycling in Canada, please refer to Switch the Stat at
www.switchthestat.ca
NOTICE: To avoid possible compressor damage, do not run air conditioner if the outside temperature drops below 50°F (10°C).
Customer assistance
For assistance with this product, please visit
resideo.com.
Or call Resideo Customer Care toll-free at
1-800-468-1502.
To save time, please note your model number and date code before calling.
Pull at the bottom to remove the thermostat from the wallplate.
Turn the thermostat over to find the model number and date code.
-
Turn Off Power to Heating/Cooling System
-
Remove Old Thermostat
Remove old thermostat but leave wallplate with wires attached.
**** If you have an older thermostat with a sealed mercury tube, turn to page 2 for proper disposal instructions.
-
Label Wires with Tags
Label the wires using the supplied wire labels as you disconnect them.
www.honeywellhome.com -
Separate Wallplate from New Thermostat
Remove the wallplate from the new thermostat and mount it onto the wall.
-
Mount Wallplate
Mount the new wallplate using the included screws and anchors.
If your box contains red anchors, drill 7/32” (5.6 mm) holes. If your box contains yellow anchors, drill 3/16” (4.8 mm) holes. -
Connect Wires
Simply match wire labels.
If labels do not match letters on the thermostat, check “Alternate Wiring” on page 6 and connect to the terminal as shown (see notes, below).
The thermostat does not work on Heat Pumps with auxiliary/backup heat.
We are here to help. Call 1-800-468-1502 for wiring assistance.
Alternate Wiring
If wires will be connected to both R and Rc terminals, remove the metal jumper.
Do not use C or X. Wrap the bare end of the wire with electrical tape.
If you have a heat pump without auxiliary/backup heat connect O or B, not both. If you do not have a heat pump, do not connect B. Wrap the bare end of the wire with electrical tape.
Place a jumper (a piece of wire) between Y and W if you are using a heat pump without auxiliary/backup heat -
Install Batteries
-
Set fan operation switch
Move the switch to the proper setting:
Gas or Oil: For gas or oil heating systems, leave the fan operation switch in this factory-set position (for systems that control the fan in a call for heat).
Electric or Heat Pump: Change the switch to this setting for heat pump or electric heat systems. (This setting is for systems that allow the thermostat to control the fan in a call for heat if a fan wire is connected to the G terminal.) -
Install Thermostat onto Wallplate
Install thermostat onto the wall plate on the wall. -
Turn Power Back On
Turn the power back on to the heating/cooling system. -
If your system type is…
If your system type is:
• Single-Stage Heat and Cool
• Heat Only or Cool Only
Congratulations, you’re done!
If your system type is:
- Heat pump
- High-efficiency furnace
- Hot water
- Electric furnace
- Gas/oil steam
- Gravity system
Continue with Advanced Installation to match your thermostat to your system type.
If you are not sure of your system type or if you have other questions,
call us toll-free at 1-800-468-1502.
This thermostat works on 24 volt or 750 mV systems. It will NOT work on
multistage conventional systems.
Advanced Installation
Enter System Setup
To enter the system setup, press and hold both the and buttons until the display changes (approximately 5 seconds). Changing Settings
- Press the OR button to change the setting.
- Press the and buttons simultaneously for one second to advance to the next function.
- Press the RUN button to exit and save settings.
NOTE: If you do not press any button for 60 seconds while you are in the setup menu, the thermostat automatically saves any changes made and exits the menu.
Function| Description
Press the or button to| Setting
---|---|---
5| select your heating system and
optimize its operation| 5 Gas or oil furnaces: Use this setting if you
have a standard gas or oil furnace that is less than 90% efficient.
6 Electric furnace: Use this setting if you have any type of electric
heating system.
3 Heat pumps, hot water, or high-efficiency furnace:
Use this setting if you have a hot water system or a gas furnace of greater
than 90% efficiency.
2 Gas/oil steam or gravity system: Use this setting if you have a steam
or gravity heat system.
14| select Fahrenheit or Celsius
temperature display| 0 Fahrenheit temperature display (°F)
1 Celsius temperature display (°C)
15*| select Compressor Protection settings| 1 On
0 Off
20| select clock display| 0 12-hour display
1 24-hour display
40
(RTH2300
only)| restore program schedule to default settings| 0 Off
1 On Program schedule default settings is listed on page 11.
- Compressor Protection: This feature forces the compressor to wait approximately 5 minutes before restarting, to prevent equipment damage. During the wait time, the message “Cool On” or “Heat On” is displayed on the screen.
About your new thermostat
Your new Resideo thermostat has been designed to give you many years of reliable service and easy-to-use, push-button climate control.
- Backlit display on RTH2300
- Displays ambient (measured) temperature at all times
- One-touch access to the setpoint temperature
- Preset program settings
- Temporary and permanent override of schedule
- Built-in compressor protection
Thermostat controls
Display screen
Set the time and day
1. Press the SET button, then press or to set the clock time.
2. Press the SET button, then press or to to select the day of
the week.
3. Press RUN to save & exit.
NOTE: If the clock flashes, the thermostat will follow your settings for the Monday “Wake” time period until you reset the time and day.
Program Schedule
You can program four time periods each day, with different settings for
weekdays and weekends. We recommend the pre-set settings (shown in the table
below) since they can reduce your heating/cooling expenses. Wake – Set to the time
you awaken and the temperature you want during the morning, until you leave
for the day.
Leave – Set to the time you leave home and the temperature you want while
you are away (usually an energy-saving level).
Return – Set to the time you return home and the temperature you want
during the evening, until bedtime.
Sleep – Set to the time you go to bed and the temperature you want
overnight (usually an energy-saving level).
NOTE: Leave and Return periods can be canceled on weekends.
To adjust program schedules (RTH2300)
- Press SET until Set Schedule is displayed.
- Press or to set your weekday Waketime (Mo-Fr), then press SET.
- Press or to set the temperature for this time period, then press SET.
- Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each weekday time period.
- Press SET to set weekend time periods (Sa & Su), then press RUN to save & exit.
NOTE: Make sure the thermostat is set to the system you want to program (Heat or Cool).
To adjust program schedules (RTH221)
- Press SET until Set Schedule is displayed.
- Press or to set your Waketime (Mo-Su), then press SET.
- Press or to set the temperature for this time period, then press SET.
- Set time and temperature for the next time period (Leave). Repeat steps 2 and 3 for each time period.
- Press RUN to save & exit.
NOTE: Make sure the thermostat is set to the system you want to program (Heat or Cool).
Program schedule override (temporary)
Press or to immediately adjusts the temperature. This will temporarily
override the temperature setting for the current time period.
“Temporary” will appear on the display and the current program period will
flash.
The new temperature will be maintained only until the next programmed time
period begins (see page 11).
To cancel the temporary setting at any time, press RUN.
NOTE: Make sure the thermostat is set to the system you want to control
(heat or cool).
Program schedule override (permanent)
Press HOLD to permanently adjust the temperature. This will override the
temperature settings for all time periods. The “Hold” feature turns off the program schedule and
allows you to adjust the thermostat manually, as needed.
Whatever temperature you set will be maintained 24 hours a day, until you
manually change it, or press RUN to cancel “Hold” and resume the program
schedule. NOTE: Make sure the thermostat
is set to the system you want to control (heat or cool).
Built-in compressor protection
This feature helps prevent damage to the compressor in your air conditioning
or heat pump system.
Damage can occur if the compressor is restarted too soon after shutdown. This
feature forces the compressor to wait 5 minutes before restarting.
During the wait time, the display will flash the message Cool On (or Heat On
if you have a heat pump). When the safe wait time has elapsed, the message
stops flashing and the compressor turns on.
Battery replacement
Install two fresh AAA batteries when Lo Batt flashes on the screen. Lo, att
appears for 60 days before the batteries are depleted. Replace batteries once
a year, or when you will be away for more than a month.
Most settings are stored in non-volatile (permanent) memory. Only the clock
and the day must be set after you replace the batteries.
Pull at the bottom to remove the thermostat from the wallplate. ****Set the
System switch to Off before removing the batteries. Otherwise, the
heating/cooling system could remain activated even when batteries are removed.
Turn the thermostat over, insert fresh AAA alkaline batteries, then reinstall the thermostat.
Troubleshooting
If you have difficulty with your thermostat, please try the following
suggestions.
Most problems can be corrected quickly and easily.
Display is blank| •Check the circuit breaker and reset if necessary.
•Make sure the power switch at the heating & cooling system is on.
•Make sure the furnace door is closed securely.
•Make sure fresh AM alkaline batteries are correctly installed.
---|---
The heating
or cooling system does not respond| •Set system switch to Heat. Make sure the
temperature is set higher than the Inside temperature.
•Set system switch to Cool. Make sure the temperature is set lower than the
Inside temperature.
•Wait 5 minutes for the system to respond.
Temperature| Make sure heating and cooling temperatures are set to acceptable
ranges:
•Heat: 40° to 90°F (4.5° to 32°C).
•Cool: 50° to 99°F (10° to 37°C).
settings do not change
“Cool On” or “Heat On” is flashing| •Compressor protection feature is engaged.
Wait 5 minutes for the system to restart safely, without damage to the
compressor.
“Heat On” is not displayed| •Set the System switch to Heat and set the
temperature level above the current room temperature.
| •Set the System switch to Cool, and set the temperature level below the
current room temperature.
“Cool On” is not displayed
For assistance with this product, please visit resideo.com or call Resideo Customer Care toll-free at 1-800-468-1502.
1-year limited warranty
Resideo warrants this product, excluding battery, to be free from defects in
workmanship or materials, under normal use and service, for a period of one
(1) year from the date of first purchase by the original purchaser. If at any
time during the warranty period the product is determined to be defective due
to workmanship or materials, Resideo shall repair or replace it (at Resideo’s
option). If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the
place from which you purchased it; or
(ii) call Resideo Customer Care at
1-800-468-1502. Customer Care will make
the
determination whether the product should be returned to the following address:
Resideo Return Goods, 1985 Douglas Dr. N., Golden Valley, MN 55422, or whether
a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty
shall not apply if it is shown by Resideo that the defect was caused by damage
that occurred while the product was in the possession of a consumer.
Resideo’s sole responsibility shall be to repair or replace the product within
the terms stated above. RESIDEO SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING,
DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED,
OR ANY OTHER FAILURE OF THIS PRODUCT.
Some states do not allow the exclusion or limitation of incidental or
consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY RESIDE MAKES ON THIS PRODUCT. THE
DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IS HEREBY LIMITED TO
THE ONE-YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations
on how long an implied warranty lasts, so the above limitation may not apply
to you.
This warranty gives you specific legal rights, and you may have other rights
which vary from state to state. If you have any questions concerning this
warranty, please write Resideo Customer Care, 1985 Douglas Dr, Golden Valley,
MN 55422 or call 1-800-468-1502.
Resideo Technologies Inc.
1985 Douglas Drive North, Golden Valley, MN 55422
1-800-468-1502
33-00100ES—03 M.S. Rev. 02-20 | Printed in the United States
©2020 Resideo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International, Inc. This product is manufactured by Resideo Technologies, Inc.
and its affiliates.
Todos los derechos reservados. La marca comercial Honeywell Home see utiliza
bajo licencia de Honeywell International, Inc.
Este producto es fabricado por Resideo Technologies, Inc. y sus afiliados.
References
- Smart Home Products and Systems | Resideo
- Honeywell Home | Smart Home Comfort and Security
- Switch the 'Stat – Stewardship Program Focused on Recovering and Recycling Thermostat
- Home - Thermostat Recycling Corporation (TRC)
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>