Milesight VS132 LoRaWAN 3D ToF People Counting Sensor User Guide
- June 3, 2024
- Milesight
Table of Contents
3D ToF People Counting Sensor
Featuring LoRaWAN®
VS132
VS132 LoRaWAN 3D ToF People Counting Sensor
|
---|---
https://www.milesight-iot.com/milesight-cloud-app-download/| https://www
.milesight-iot.com/quick-start-collection/
All software & files can be downloaded from https://www.milesight-iot.com /documents-download/
Better Inside, More in Sight
Milesight IoT Co., Ltd. www.milesight-iot.com
Packing List
Please check the package contents to verify that you have received the items below.
1 × VS132 Sensor| 1 × DC Power Adapter| 2 × Ear Mounting Kits
4 × Wall Mounting Kits| 1 × Quick Start Guide| 1 × Warranty Card
Hardware Introduction
Installation
Recommended Height
Since the detection range is 0.5m to 3m, the maximum installation height
should be 3m and the minimal installation height should always be 0.5m higher
than the object.
Monitored areas for people counting at different heights:
Height (m) | Monitored Area (m) |
---|---|
2.4 | 5.01 × 3.18 |
2.5 | 5.22 × 3.31 |
2.6 | 5.43 × 3.44 |
2.7 | 5.64 × 3.57 |
2.8 | 5.85 × 3.71 |
2.9 | 6.06 × 3.84 |
3.0 | 6.27 × 3.97 |
Installation Steps
- Fix the two mounting ears to both side of the device with screws.
- Drill 4 holes on the ceiling or wall according to the mounting ear’s hole and fix the wall plugs into the holes, then fix the device to the wall plugs with mounting screws. When installing the device, it’s suggested to fix the two screws on the top at first.
Ceiling Mount
Embedded Mount
Top-Lintel Mount at Entrance
Besides, this device can be mounted with the mounting stand via the threaded
hole.
Installation Notes
- Make sure the detection part of sensor is facing straight down and in line with the ceiling.
- Avoid strong light, like direct sunlight or IR LED, in the detection area.
- Do not install the sensor close to glass or mirror.
- When the sensor is mounted on the wall, ensure the detection part of the sensor is horizontally close to the lintel of the door.
Power Supply
VS132 can be powered by 802.3at standard PoE or DC power adapter. Choose one of the following methods to power up the device:
- Powered by DC Power Adapter
Access from Web Browser
VS132 sensor provides user-friendly web GUI for configuration and users can
access it via Wi-Fi connection or Ethernet port. Users need to set the
password when using the device for the first time. The default settings are as
below:
Wi-Fi SSID: People Counter_xxxxxx (can be found on the label) Wi-Fi IP:
192.168.1.1
ETH IP: 192.168.5.220
Here are 2 ways of accessing the web GUI:
Wireless Mode: Enable the Wireless Network Connection on your computer, search
for corresponding Wi-Fi SSID to connect it, then type 192.168.1.1 to access
the web GUI.
Wired Mode: Connect the device to computer via Ethernet port, assign the IP
address of computer to 192.168.5.xxx manually, then type 192.168.5.220 to
access the web GUI.
VS132 is a LoRaWAN® 3D ToF people counting sensor designed to count the number
of people entering and exiting. Applied the most advanced Time-of-Flight
technology, VS132 only obtains depth maps instead of images to protect privacy
and provide a high level of accuracy up to 99.5%. Cooperating with Milesight
LoRaWAN®
gateway and the Milesight IoT Cloud solution, it allows users to monitor the
flow of people and trigger linkage to control other devices via browser or
mobile App remotely.
With easy installation, VS132 has great use in entrances or corridors of
retail stores, malls, offices, subways, etc.
Features
- Up to 99.5% accuracy basing on advanced 3D Time-of-Flight technology
- Obtain depth map without images capturing, free from privacy concerns
- Effective in low-light or complete darkness environments
- Bi-directional Counting
- Able to store locally one million data records
- DC or PoE power supply optional
- Exquisite design for multiple installation scenarios
- Equipped with Wi-Fi and Ethernet port for web GUI configuration
- Acquire people counting data either from LoRaWAN® or Ethernet port (CGI)
- Function well with standard LoRaWAN gateways and network servers
- Quick and easy management with Milesight IoT Cloud®
Applications
- Offices and meeting rooms occupancy monitoring
- Customer flow analysis on stores and shopping malls
- Passenger flow analysis on buses or subways
Specifications
Wireless Transmission
Protocol | LoRaWAN® |
---|---|
Frequency | CN470/IN865/RU864/EU868/US915/AU915/KR920/AS923-1&2&3&4 |
Max Tx Power | 22 dBm (915 MHz) |
Sensitivity | -137 dBm @300bps |
Mode | OTAA/ABP Class C |
People Counting
ToF FoV | 92.5 ° Horizontal, 67 ° Vertical |
---|---|
Detection Range | 0.5 to 3m |
Installation Height | ≤ 3m |
Accuracy | >99.5% |
Local Storage | 1, 000, 000 data records |
Advanced Setting | Entrance and exit area customization |
Interface
Wi-Fi | IEEE 802.11 b/g/n, 2.4GHz, only support configuration |
---|---|
Ethernet Port | 1 × RJ45 10/100 Mbps Ethernet Port (PoE PD), provides CGI for |
integration
Power Input| 2-pin 5.08 mm Terminal Block
Physical Characteristics
Power Supply| 1. 12 VDC, 2A by Terminal Block
2. 1 × 802.3 at PoE input
---|---
Power Consumption| Typical 7.5 W, max 28 W
Operating Temperature| -10°C ~ +60°C
Storage Temperature| -20°C ~ +60°C
Relative Humidity| 0 ~ 95% (Non-condensing)
Color & Material| Black, Aluminum Alloy
Dimension| 140 × 50 × 50 mm (5.51 × 1.97 × 1.97 in)
Installation| Ceiling Mounting, Wall Mounting, Embedded Mounting
Monitored Area
VS132 is engineered for bi-direction entrances or corridors. Since the detection range is 0.5m to 3m, the maximum installation height should be 3m and the minimal installation height should always be 0.5m higher than the object.
Installation Height (m) | Monitored Area (m) |
---|---|
2.4 | 5.01 × 3.18 |
2.5 | 5.22 × 3.31 |
2.6 | 5.43 × 3.44 |
2.7 | 5.64 × 3.57 |
2.8 | 5.85 × 3.71 |
2.9 | 6.06 × 3.84 |
3.0 | 6.27 × 3.97 |
FCC Warning:
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.
Milesight loT Co., Ltd.
www.milesight-iot.com
Tel: 86-592-5085280 Support email:
iot.support@milesight.com
Sales email: iot.sales@milesight.com
Website: www.milesight-iot.com
Address: Building CO9, Software Park Phase Ill, Xiamen 361024, Fujian, China
https://www.milesight-iot.com/