IMPORTANT: Your keypad may need to be hard wired due to the fact that it
must accept interference according to FCC regulations listed below. For
example, applications that are relativity close to cell towers or airports may
receive intermittent interference and require hard-wiring.
The GTO Digital Keypad is a multipurpose keypad that can work with other
applications in addition to GTO gate openers and locks. As a wired keypad it
can operate garage door openers and gate openers, that require 24 volts or
less and accept normally open contacts.
As a wireless keypad it can be used with any gate or garage door opener that
receives a 318 MHz RF signal. The keypad must be used in conjunction with the
GTO garage door receiver kit (part # RB709) on any other garage door.
SAFETY NOTE: Never install the keypad where a person can reach through the gate to activate it, or where a person can touch the gate while activating the keypad. The recommended mini-mum distance between the gate and keypad is 10ft.
FCC WARNING: Changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in particular
installations. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following measures:
- Reorient or replace the receiver antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Limited One Year Warranty
GTO, Inc. gate opener accessories are warranted by the manufacturer against
defects in workmanship for a period of one (1) year from the date of purchase,
provided recommended installation procedures have been followed.
In the case of product failure due to defective material or manufacturer
workmanship within the one (1) year warranty period, the accessory will be re-
paired or replaced (at the manufacturer’s option) at no charge to the
customer, if returned freight prepaid to GTO, Inc., 3121 Hartsfield Rd.,
Tallahassee, FL 32303. IMPORTANT: Call 850/575-4144 or fax 850/575-8950 for a
Return Goods Authorization (RGA) number before returning goods to factory.
Products received at the factory without an RGA will not be accepted.
Replacement or repaired parts are covered by this warranty for the remainder
of the one (1) year warranty period. GTO, Inc. will pay the shipping charges
for return to the owner of items repaired.
The manufacturer will not be responsible for any charges or damages incurred
in the removal of the defective parts for repair, or for the reinstallation of
those parts after repair. This warranty shall be considered void if damage to
the product(s) was due to improper installation or use, connection to an
improper power source, tampering, or if damage was caused by lightning, wind,
fire, flood, insects, or other natural agent.
After the one (1) year warranty period, GTO Inc. or one of its authorized
service centers will make any necessary repairs for a nominal fee. Call GTO at
850/575-4144 for more information. This warranty gives you specific legal
rights, and you may also have other rights which may vary from state to state.
This warranty is in lieu of all other warranties, expressed or implied. NOTE:
Verification of the warranty period requires copies of receipts or other proof
of purchase. Please retain those records.
Features of the Keypad
You may program up to 25 different personal entry codes, allowing you to give
different entry codes to different users. For example, you can give a delivery
person their own entry code, which you can easily change after they have made
the delivery. This will prevent them from being able to regain access, while
still allowing those to whom you gave other entry codes full access.
After entering a valid code, pressing any key while the gate is opening will
stop the gate; pressing any key while the gate is stopped and the gate will
reverse direction. The keypad will not affect the auto-close setting of your
gate opener system.
The keypad face will light up and beeper will beep at the press of any key.
The keypad memory will recognize your entry code in a string of up to 20
digits; if it finds the correct sequence it will activate the gate opener. As a
security feature, the keypad will shut down for 40 seconds if it does not find
the correct code sequence within a 20 digit string. This will discourage an
unauthorized person from trying to use random numbers to access your property.
Your entry codes will remain stored in memory even when the batteries go dead.
The keypad will remember your entry codes as long as you don’t press the RESET
button.
Keypad Description
Keypad – Front
Keypad – Inside
Installing Batteries
NOTE: 3 AA batteries are required to power the keypad unless an external
power supply such as the gate openers power source is used. Low voltage wire
from the external power source must be connected to the POWER IN terminals on
the keypad control board, if batteries are not installed.
Step 1: Remove the two screws from the bottom of the keypad and separate
the keypad from its housing.
Step 2: Install 3 AA batteries (not included).
Wireless Installation of the Keypad
NOTE: For wireless applications, the distance from the keypad to the
opener’s receiver should not exceed 50 ft. Always test the key-pad range
before permanently mounting it.
Step 1: Mount the keypad cover using the screws provided. Set the keypad
DIP switches to match your entry transmitter’s DIP switch settings.
NOTE: If you have not changed your opener’s transmitter code from the factory setting, see the “Setting Your Personal Transmitter Code” section in the gate openers manual then set the keypad DIP switches to match the new transmitter DIP switch setting.
Step 2: Slide the keypad into the cover and secure with the small screws provided.
Wired Installation of the Keypad
NOTE: If you also plan to power the keypad with the gate opener’s power
source, run two pairs of wires as described below. One pair to hard-wire the
keypad and the other pair to connect the keypad to the gate opener’s battery.
Step 1: Turn the gate opener’s power switch OFF. Use 16 gauge, stranded,
direct burial low voltage wire (part no. RB509) to connect the keypad to the
opener control board. Run wire through PVC pipe from the ground to keypad and
from the ground to the opener control board to protect the wire from lawn
mowers or grazing animals.
Determine how the wire will enter the keypad (i.e. from the back through a
hole drilled in the mounting post or running the wire on the surface of the
post). Remove the small rectangular knock-out on the back of the keypad cover
and pull the wire into the cover. Then mount the cover to the post using the
screws provided.
Step 2: To hard-wire the keypad – strip the wires back 3/16″ and attach
the wires to the terminal block marked RELAY OUTPUT on the keypad control
board as shown to the right. Connect the other end to the opener’s control
board as shown in Control Board Connections section below.
To wire the power supply to the keypad attach the wires to the AC/DC POWER IN
terminal on the keypad control board as shown to the right. Connect the other
end to the opener’s battery – one end to the POSITIVE pole and the other to
the NEGATIVE pole.
NOTE: For a hard-wired application the jumper between the two terminals on the keypad control board must be connected (ON) as shown. This will disable the 318 MHz RF transmitter.
Step 3: Slide the keypad into the cover and secure with the small screws
provided.
Step 4: With the power to the opener turned OFF.
Remove opener control board cover and feed enough of the low voltage keypad
wire through a strain relief to reach the gate opener control board terminals.
Step 5: Attach the wires from the keypad to the opener control board
terminal blocks as shown below.
Step 6: Replace the control board cover and turn the power switch ON.
Test the keypad by entering 1 2 3 4.
Step 7: Program your ‘Personal Master Code’ and any additional entry
codes (for a total of 25 entry codes) you wish. See Programming the Keypad
section.
Control Board Connections
NOTE: If your control board doesn’t look like any of these diagrams, please call GTO Technical Service at 1-800-543-1236 or 850-575-4144 for additional support.
Programming the Keypad
Programming Interface
- All codes are four (4) digits in length.
- Entry code is a four (4) digit code needed to activate the gate.
- Master Code is needed to add, remove or reset entry codes.
- Master Code also functions as the entry code under normal operation.
- Factory default Master Code is 1234.
- STATUS light should blink and beeper should beep (once) whenever any button is pressed.
- If more than 10 seconds elapsed between key presses the unit returns to normal (idle) operating mode.
- Keypad can only enter program mode from sleep mode (keypad is turned OFF).
- Keypad will beep three times before going into sleep mode.
Program New Master Code
- Press and release PROGRAM button.
- Enter the old Master Code then press and release PROGRAM button.
- Enter 0, 6 then press and release PROGRAM button
- Enter the new Master Code then press and release PROGRAM button.
- Enter the new Master Code then press and release PROGRAM button again for confirmation.
- Beeper beeps 3 times to confirm that the new Master Code is accepted.
NOTE: If the Master Code is not a matched pair or error occurs (i.e. if
the entry code is NOT a 4-digit code) the STATUS light will flash rapidly and
the beeper will sound for 2 seconds before returning to normal operation with
old Master Code.
Example: Key press sequence to change old Master Code from 1 2 3 4 to 3 1
2 1
The round black dot is the ‘PROGRAM’ button.
Program (Add) New Entry Code
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 2 then press and release PROGRAM button. NOTE: If memory is full (all 25 locations are already programmed) the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
- Enter the new Entry Code then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the new Entry Code is accepted.
NOTE: If the code is NOT 4-digits in length or an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
Example: Key press sequence to add ‘3456’ as a new entry code. (1234 is the Master Code)
The round black dot is the ‘PROGRAM’ button.
Program (Add) New Temporary Entry Code
-
Press and release PROGRAM button.
-
Enter the Master Code then press and release PROGRAM button.
-
Enter 8, and any number between 1 thru 7 then press and release the PROGRAM button. The second number indicates the number of days after which the code will be automatically removed from memory
NOTE: If memory is full (all 25 locations are already programmed) or an invalid entry is detected then an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving. -
Enter the new Entry Code then press and release PROGRAM button.
-
Beeper beeps 3 times to confirm that the new Entry Code is accepted.
NOTE: If the code is NOT 4-digit in length or an error condition has occurred, the STATUS light will flash rapidly and the beeper will sound for 2 seconds before returning to normal operation, without saving.
Example: Key press sequence to add “3456” as a new entry code that will remain valid for 2-days only. (1234 is the Master Code)
The round black dot is the ‘PROGRAM’ button.
Example: Key press sequence to add “3456” as a new entry code that will remain valid for 7-days only. (1234 is the Master Code)
The round black dot is the ‘PROGRAM’ button.
Delete An Entry Code
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 3 then press and release PROGRAM button.
- Enter the Entry Code to be deleted then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the new Entry Code is deleted.
NOTE: If no matching code is found or the code is NOT 4-digit in length
then an error condition has occurred, the STATUS light will flash rapidly and
the beeper will sound for 2 seconds before returning to normal operation,
without saving.
Example: Key press sequence to delete entry code ‘3456’ from memory.
(1234 is the Master Code)
The round black dot is the ‘PROGRAM’ button.
Delete ALL Entry Codes
- Press and release PROGRAM button.
- Enter the Master Code then press and release PROGRAM button.
- Enter 0, 7 then press and release PROGRAM button.
- Beeper beeps 3 times to confirm that the All Entry Codes are deleted.
Example: Key press sequence to delete all entry codes from memory. (for example if 3121 is the Master Code)
The round black dot is the ‘PROGRAM’ button.
Normal Keypad Operation
- If the user enters a 4-digit code that is matched to one of the 25 stored codes. The STATUS light should blink twice and the beeper should beep twice to confirm that a matched code is entered.
- No more than 20 key presses are allowed to obtain the 4-digit entry code.
Example:
1234 is one of the codes stored in one of the memory location.
The user can enter ‘x1234’ or ‘xxxxxxxxxxxxxxxx1234’ and the gate should be
activated (x is any key). If more than 20 key presses is entered without
matching one of the codes then the unit’s STATUS light should be flashing
rapidly and no entry will be accepted for the next 40 seconds. The user must
not enter any code for at least 40 seconds before the unit returns to nor-mal
operation; otherwise it remains in this ‘lock-down’ mode. Once the user enters
a matched code, any subsequent key press within the next 40 seconds will re-
activate the keypad.
Keying Indication Summary
|
Keying Error Alert Indication
|
Keying accepted confirmation Indication
---|---|---
Master Code Setting| Speaker: continuous Beep for 2 seconds STATUS light:
rapid flashing| Speaker: Beep – Beep – Beep STATUS light: no light, no flashing
Permanent Entry Code| Speaker: continuous Beep for 2 seconds STATUS light:
rapid flashing| Speaker: Beep – Beep – Beep STATUS light: no light, no flashing
Temporary Entry Code Setting| Speaker: continuous Beep for 2 seconds STATUS
light: rapid flashing| Speaker: Beep – Beep – Beep STATUS light: no light, no
flashing
Entry Code Matching| Speaker: continuous Beep for 2 seconds
STATUS light: rapid flashing| Speaker: Beep – Beep – Beep (after non-matching
20 keying) STATUS light: no light, no flashing
If you have any questions or concerns, please contact our Technical Service
Department at 1-800-543-1236 or
850-575-4144.
GTO, Inc. • 3121 Hartsfield Road • Tallahassee, Florida 32303
Telephone 850-575-0176
Fax 850-575-8912
Website www.gtoinc.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>