Honeywell Home PROSiXSHOCK Wireless Shock/Door/Window Sensor Installation Guide

June 6, 2024
Honeywell Home

Honeywell Home PROSiXSHOCK Wireless Shock/Door/Window Sensor

The PROSiXSHOCK is a 3-zone wireless shock/door/window sensor is intended for use with Honeywell Home controls that support PROSiX™ series devices.
It provides

  • Reed switch/magnet zone
  • External wired contact zone
  • Built-in shock sensor zone (designed to protect windows and doors)

Typical shock protection area:

10 – 12 ft. diameter / 5 – 6 foot radius (3.05m ­ 3.66m diameter / 1.52m ­ 1.83m radius)
The coverage area can vary depending on the mounting surface.

INSTALLATION OPTIONS

The PROSiXSHOCK can be installed with several options:

  • Loop 1: Normally closed, built-in reed switch, used with the included magnet

  • Loop 2: Externally wired, closed-circuit contact loop connected to the Terminal Block (unsupervised)
    NOTE: Wiring limit is 3ft.

  • Loop 3: Built-in shock sensor. Red LED flashes briefly upon sensing shock

Magnet Gap specifications:
a. Make gap is at least 0.8″
b. Break gap is at least 0.95″
(reduced about 30% for steel)

MOUNT THE PROSIXSHOCK

  1. To open the device, firmly slide the front and back housings in opposite directions and pull them apart.

  2. The PROSiXSHOCK sensor MUST be mounted as follows:
    ● On swinging doors: mount on upper corner of door (not door frame); opposite hinge is ideal
    ● On sliding windows and doors: on the frame (on moving section when magnet is used)

  3. Mount sensor as shown, using the double-sided tape and screws provided.

  4. Secure the front cover with the #2 x 1/4″ screw.
    After enrolling and before mounting, verify adequate signal strength by conducting a sensor test (see controller’s instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.

ENROLL AND SET UP

You must enroll the device in the control. Refer to the control’s programming instruction for detailed procedures.

Set the controller in Programming Mode and when prompted:

  1. Pull the battery tab to activate the PROSiXSHOCK. (Use the magnet if the battery tab is removed.)

  2. The LED flashes (up to about 20 seconds*) during enrollment. · All services (Reed, Terminal Block, and Shock) are enrolled in sequential (or next available) zone numbers. · The device sends its unique MAC ID (Serial Number); the controller registers the device and displays the transmitter data on screen.
    *NOTE: Enrollment time varies depending on the signal strength between the device and the controller.

  3. When done, the LED is ON for 3 seconds to confirm enrollment.
    NOTE: If the device is not successfully enrolled during the enrollment period, the LED turns off and the device powers down. Activate a tamper, wired service (loop) or the reed switch to restart the enrollment process.

  4. Program each zone being used:
    Reed Switch Zone (loop 1)
    Terminal Block Zone (loop 2)
    Shock Zone (loop 3)


    IMPORTANT: Once enrolled in a system, the PROSiXSHOCK cannot be used with another controller until it is removed from the current controller. See the Controller’s instructions for details.
    After enrolling, verify adequate signal strength by conducting a sensor test (see controller’s instructions) with the device in its intended mounting location. Adjust the device location and orientation as necessary.

DEMO MODE (NO ENROLLMENT NEEDED)

  1. Remove the battery pull tab from the device.
  2. Install the mounting plate onto the back cover to insure both tampers are closed.
  3. The device will attempt to pair with a control (Flashing green LED for ~20 seconds, which is visible through the top cover)
  4. The Green LED will turn off and within a minute the device is defaulted to maximum shock sensitivity for 10 minutes.
  5. Strike the device in the palm of your hand, the red LED will flash through the front cover indicating a shock event.
  6. When ready to learn the device into a control open/close the cover again or trip the reed switch using a magnet.
    The pairing time window will start again.

SENSITIVITY ADJUSTMENT

NOTE: The PROSiXSHOCK sensitivity must be set after mounting and enrollment. See the Controller’s instructions for details.

The PROSiXSHOCK has the following sensitivity settings: Maximum ­ Medium ­ Low – Lowest

  1. Verify the sensitivity setting is adequate by striking the protected surface with the soft part of your fist at the point farthest from the device.
  2. If sensitivity is adequate the red LED flashes briefly (remove cover for easier viewing of LED). If the LED does not flash, select the next higher sensitivity setting and repeat from step 1.

24-HOUR ENROLLMENT DELETION AND DEFAULT

If the device is enrolled in a panel different than the intended panel, and you are unable to delete it from the unintended panel, reset the device to factory default setting:

  1. Open the cover and remove the battery.
  2. Hold down the tamper switch while reinserting the battery. Rapid LED flashing indicates successful deletion (LED flashes as if in enrollment mode). If LED does not flash, delete was not successful.
  3. Reattach the cover.

This procedure is available for 24 hours after enrollment with a panel and the device remains powered (battery installed).

LED INDICATIONS

LED Status
Rapid Flashes for about 20 seconds, then ON for 3 seconds Power Up –

Enrollment
Slow Flashes| Power Up – Device enrolled; Wall or Cover Tamper activated. To stop flashes, clear the tamper condition by reconnecting to the mounting plate and reattaching the cover. It also times out after 10 minutes
ON (while in Programming Mode)| Sensor LED toggles on and off when the sensor is selected. See Sensor Location Feature.

BATT ERY REPLACEMENT

  • Push the bottom latch of the mounting bracket back to disengage it. Then slide the back housing up and out to remove it from the mounting bracket.

  • Slide the front and back housings in opposite directions and pull the housings apart.

  • Remove the battery, wait 10 seconds, t hen insert a new battery. Recommended batteries:
    Duracell DL123A, Huiderui CR123A, Panasonic CR123A, Resideo 466

  • Place the front and back housings together and slide them together.

    BATTERY CAUTION: Risk of fire, explosion and burns. Do not recharge, disassemble, heat above 212°F (100°C) or incinerate. Dispose of used batteries properly. Keep away from children.
    NOTE: Constant exposure to high or low temperature or high humidity may reduce battery life.

SPECIFICATIONS

Battery| 1 x 3V Lithium, Resideo 466, Panasonic CR123A, Duracell DL123A or Huiderui CR123A
---|---
Tamper| Cover and Wall
RF Frequency| 2.4GHz
Operating Temperature| 32° – 122° F / 0° – 50° C (Agency Compliance 32° – 120° F / 0° – 49° C)
Relative Humidity| 95% max. (Agency Compliance – 93% max.), non- condensing
Dimensions| 1” H x 3.13” L x 1.61” W / 25.5 mm H x 79.5 mm L x 41 mm W

APPROVAL LISTINGS

FCC / IC
cETLus Listed
Conforms to UL 634 Certified to ULC/ORD-C634, ULC S306
Other Standards:
RoHS
Product must be tested at least once each year

FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User’s Manual. Unauthorized changes or modifications could void the user’s authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device statement can be viewed at: https://customer.resideo.com/en- US/support/residential/codes-and-standards/FCC15105/Pages/default.aspx
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, Ph: 516-577-2000

The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end-of-life equipment will help prevent potential negative consequences for the environment and human health. Any attempt to reverse- engineer this device by decoding proprietary protocols, de-compiling firmware, or any similar actions is strictly prohibited.

SUPPORT & WARRANTY INFORMATION

For the latest documentation and support, please go to:
www.resideo.com

For the latest warranty information, please go to: www.security.honeywellhome.com/warranty


The Honeywell Home Trademark is used under license from Honeywell International Inc.
This product is manufactured by Resideo Technologies, Inc. and its affiliates.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Honeywell Home User Manuals

Related Manuals