milwaukee 2951-20 Radio + Charger User Manual
- June 6, 2024
- Milwaukee
Table of Contents
OPERATOR’S MANUAL
Cat. No. / No de cat.
2951-20
M12™ RADIO + CHARGER
WARNING To reduce the risk of injury, the user must read and understand the operator’s manual.
IMPORTANT SAFETY INSTRUCTIONS
RADIO SAFETY
WARNING
-
Read these instructions.
-
Keep these instructions.
-
Heed all warnings.
-
Follow all instructions.
-
Do not use this apparatus near water.
-
Clean only with a dry cloth.
-
Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
-
Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers that produce heat.)
-
Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding-type plug has two blades and a third grounding prong.
The wide blade or the third prong is provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for the replacement of the obsolete outlet. -
Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
-
Only use attachments/accessories specified by the manufacturer.
-
Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid injury from tip-over. -
Unplug this apparatus during lightning storms or when unused for long periods of time.
-
Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged in any way,such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, has been dropped, or is missing battery doors. -
WARNING
To reduce the risk of fire or electric shock, do not ex- pose this apparatus to rain or moisture. Do not place open flames or candles near or on the radio. -
Only plug the power supply into a readily accessible outlet to allow the appliance to be unplugged quickly.
-
Only operate this apparatus in a well-ventilated area.
-
Battery-operated radio with integral batteries or a separate battery pack must be recharged only with the specified charger for the battery. A charger that may be suitable for one type of battery may create a risk of fire when used with another battery.
-
Use battery-operated radio only specifically designated battery packs. The use of any other batteries may create a risk of fire.
-
When the battery pack is not in use, keep it away from other metal objects like paper clips, coins, keys, nails, screws, or other small metal objects that can make a connection from one terminal to another. Shorting the battery terminals together may cause sparks, burns, or a fire.
-
Avoid body contact with grounded surfaces such as pipes, radiators, ranges, and refrigerators.
There is an increased risk of electric shock if your body is grounded. -
Do not use any adaptor plugs.
-
When operating a radio outside, use an outdoor extension cord marked “W-A” or “W”. These cords are rated for outdoor use and reduce the risk of electric shock.
-
Never disassemble the radio or try to do any rewiring on the radio’s electrical system.
-
Do not expose this apparatus to dripping and splashing, or place objects filled with liquids on this unit.
-
Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE service facility for a free replacement.
-
This radio + charger is designed to be powered by a standard 120 volt AC line or AC generator. The radio can also be powered using a MILWAUKEE M12™ Li-Ion battery pack. Radio + charger must be plugged into an appropriate receptacle. Do not attempt to use any other voltage or power supply.
CHARGER SAFETY -
SAVE THESE INSTRUCTIONS – THIS OPERATOR’S MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR MILWAUKEE LI-ION M12™ RADIO + CHARGER.
-
BEFORE USING, READ THIS OPERATOR’S MANUAL, YOUR BATTERY PACK OPERATOR’S MANUAL, AND ALL LABELS ON THE BATTERY PACK AND RADIO + CHARGER.
-
CAUTION – TO REDUCE THE RISK OF INJURY, CHARGE MILWAUKEE LI-ION PACKS ONLY IN THEIR MILWAUKEE LI-ION CHARGER.
Other types of chargers may cause personal injury or damage.
The battery pack and charger are not compatible with V™-technology or NiCd systems. Do not wire a battery pack to a power supply plug or car cigarette lighter.
Battery packs will be permanently disabled or damaged. -
AVOID DANGEROUS ENVIRONMENTS. Do not charge the battery pack in the rain, snow, damp or wet locations. Do not use a battery pack or charger in the presence of explosive atmospheres (gaseous fumes, dust, or flammable materials) because sparks may be generated when inserting or removing the battery pack, possibly causing a fire.
-
CHARGE IN A WELL-VENTILATED AREA. Do not block charger vents. Keep them clear to allow proper ventilation. Do not allow smoking or open flames near a charging battery pack. Vented gases may explode.
-
MAINTAIN CHARGER CORD. When unplugging the charger, pull the plug rather than the cord to reduce the risk of damage to the electrical plug and cord. Never carry a charger by its cord. Keep cord from heat, oil, and sharp edges. Make record will not be stepped on, tripped over, or subjected to damage or stress. Do not use the charger with a damaged cord or plug. Have a damaged charger replaced immediately.
-
DO NOT SHORT CIRCUIT. A short-circuited battery pack may cause fire, personal injury, and product damage. A battery pack will short circuit if a metal object makes a connection between the positive and negative contacts on the battery pack.
Do not place a battery pack near anything that may cause a short circuit, such as coins, keys, or nails in your pocket. -
DO NOT ALLOW FLUIDS TO FLOW INTO THE BATTERY PACK.
Corrosive or conductive fluids, such as seawater, certain industrial chemicals, and bleach or bleach-containing products, etc., can cause a short circuit. -
DO NOT USE AN EXTENSION CORD UNLESS IT IS ABSOLUTELY NECESSARY. Using the wrong, damaged, or improperly wired extension cord could result in the risk of fire and electrical shock. If an extension cord must be used, plug the charger into a properly wired 16 gauge or larger extension cord with pins that are the same number, size, and shape as the pins on the charger. Make sure that the extension cord is in good electrical condition.
-
USE ONLY RECOMMENDED ATTACHMENTS.
Use of an attachment not recommended or sold by the battery charger or battery pack manufacturer may result in a risk of fire, electric shock or personal injury. -
UNPLUG CHARGER when not in use. Remove battery packs from unplugged chargers.
-
TO REDUCE THE RISK OF ELECTRIC SHOCK, always unplug the charger before cleaning or maintenance. Use a Ground Fault Circuit Interrupter (GFCI) to reduce shock hazards.
-
STORE YOUR BATTERY PACK AND CHARGER in a cool, dry place. Do not store battery packs where temperatures may exceed 120°F (50°C) such as in direct sunlight, a vehicle, or a metal building during the summer.
Federal Communications Commission
WARNING
Changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
EXTENSION CORDS
Double insulated tools can use either a two or three-wire extension cord. As
the distance from the supply outlet increases, you must use a heavier gauge
extension cord. Using extension cords with inadequately sized wire causes a
serious drop in voltage, resulting in loss of power and possible tool damage.
Refer to the table shown to determine the required minimum wire size.
The smaller the gauge number of the wire, the greater the capacity of the
cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge
cord.
When using more than one extension cord to make up the total length, be sure
each cord contains at least the minimum wire size required. If you are using
one extension cord for more than one tool, add the nameplate amperes and use
the sum to determine the required minimum wire size.
Guidelines for Using Extension Cords
- If you are using an extension cord outdoors, be sure it is marked with the suffix “W-A” (“W” in Canada) to indicate that it is acceptable for outdoor use.
- Be sure your extension cord is properly wired and in good electrical condition. Always replace a damaged extension cord or have it repaired by a qualified person before using it.
- Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
- Unplug all cords during lightning storms or when unused for long periods of time.
Recommended Minimum Wire Gauge
**For Extension Cords***
Nameplate Amps| Extension Cord Length
25′| 50′| 75′| 100′| 150′
0 – 2.0| 18| 18| 18| 18| 16
2.1 – 3.4| 18| 18| 18| 16| 14
3.5 – 5.0| 18| 18| 16| 14| 12
5.1 – 7.0| 18| 16| 14| 12| 12
7.1 – 12.0| 16| 14| 12| 10| –
12.1 – 16.0| 14| 12| 10| –| –
16.1 – 20.0| 12| 10| –| –| –
- Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightning flash with the arrowhead symbol, within an equilateral triangle,
is intended to alert the user to the presence of uninsulated “dangerous
voltage” within the product’s enclosure that may be of sufficient magnitude to
constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the
user to the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
GROUNDING
Double Insulated Radios:
Radios with Two Prong Plugs
Radios marked “Double Insulated” do not require grounding. They have a special
double insulation system that satisfies OSHA requirements and complies with
the applicable standards of Underwriters Laboratories, Inc., the Canadian
Standard Association, and the National Electrical Code. Double Insulated
radios may be used in either of the 120-volt outlets shown in Figures A and B.
SYMBOLOGY
| Volts
---|---
| Direct Current
| Alternating Current
| Amps
| Hertz
| Double Insulated. The tool does not require grounding.
| Presence of important operating instructions.
| CAUTION Risk of electric shock.
| Federal Communications Commission
| UL Listing for Canada and U.S.
SPECIFICATIONS
Cat. No. …………………………………………….. 2951-20
Input AC Volts ……………………………………….120 AC
Input AC Amps …………………………………………….1 A
Input DC Volts ………………………………………. 14 DC
Input DC Amps ……………………………………………3 A
Output Volts ………………………………………….. 12 DC
Output Amps ……………………………………………….1 A
Battery Type ………………………………………….M12™
Charger Type…………………………………………M12™
Recommended Operating Temperature *
Battery and Charger .. 40°F to 104°F (5°C to 40°C)
Battery and Tool ….. 14°F to 104°F (-10°C to 40°C)
FUNCTIONAL DESCRIPTION
![milwaukee 2951 20 Radio + Charger
- Display](https://manuals.plus/wp-content/uploads/2021/10/milwaukee-2951-20 -Radio-Charger-Display.png)
1. PRESET button
2. Bluetooth button
3. AM/FM button
4. CLOCK button
5. On/Off button
6. Volume down button
7. Volume up button
8. Seek buttons| 9. Antenna
10. Battery bay
11. USB/12V DC compartment
12. Handle
13. Charger indicators*
14. Display
15. Tweeter
16. Full range speaker
---|---
* Charger Indicators
When a battery pack is inserted into the charger, the LEDs will indicate the
following:
| Continuous red: Charging
---|---
| Continuous green light: Charging is complete
| Flashing red: Battery is too hot/cold
Charging will begin when the battery reaches the correct charging temperature
| Flashing red/green: Damaged or faulty battery pack
RADIO ASSEMBLY
WARNING
Recharge only with the charger specified for the battery. For specific
charging instructions, read the operator’s manual supplied with your charger
and battery.
Power
The MILWAUKEE M12 ™ Radio + Charger can be powered by MILWAUKEE M12™ Li-Ion
battery packs or a standard wall outlet. When plugged into a wall outlet, the
battery bay will charge MILWAUKEE M12™ Li-Ion battery packs (see Charger
Operation).
Inserting/Removing Battery Pack
- To insert the battery pack, slide it into the battery bay.
- To remove the battery pack, pull the battery pack off of the bay.
Low Battery Indicator
When the radio is powered by a battery pack and its charge falls below 10%,
the low battery indicator is displayed.
Battery Pack Protection
To protect the life of the battery pack, the radio will shut off when the
battery’s charge becomes too low.
If this happens, plug Radio + Charger into a 120V outlet and charge the
battery pack according to Charger Operation.
USB Power Outlet
This outlet can be used to charge a cell phone, power an MP3 player or any
other device that uses less than 2.1 A of DC electrical current.
NOTE: Any device that uses more than 2.1 A of DC electrical current will trip
a self-resetting overload and disable the output.
RADIO OPERATION
WARNING
Always remove the battery pack before changing or removing accessories. Only
use accessories specifically recommended for this radio.
Others may be hazardous.
To reduce the risk of fire or electric shock, do not expose this radio to
rain or moisture.
Turning On/Off and Controlling Volume
Plug the cord into an appropriate AC outlet or install a battery pack.
Press and hold the On/Off button until the radio turns ON or OFF. The radio
station (frequency) is displayed. To display the time, press the CLOCK button.
Volume is restored to the last setting.
NOTE: When the Radio + Charger is running on battery power, the display will
dim after 5 minutes to reduce power use.
Use the Volume up and down buttons to increase or decrease the volume.
Setting the Clock
- Press and hold the CLOCK button until the hour begins to flash.
- Use the ◄ and ► buttons to change the hour.
- Press the CLOCK button again. The minutes will begin to flash. Use the ◄ and ► buttons to change the minutes.
- Press the CLOCK button again to save.
EQ Adjustment
Press and hold the AM/FM button to enter tuning mode. Use the ◄ and ► buttons
or and buttons to adjust Treble, and then Bass.
Selecting Band
Push the AM/FM button to select AM or FM
Tuning and Seeking
Press the ◄ and ► buttons to move up and down the band. Press, hold and
release the ◄ and ► buttons to SEEK through the band. When a station is found,
the SEEK will stop.
PRESET Stations
To set the PRESET stations:
- Tune to desired station.
- Press and hold the PRESET button until the PRESET indicator on the display begins to flash.
- Use the ◄ and ► buttons to select the PRESET location for the station. Five locations (1-5) are available for both AM and FM.
- Press the PRESET button to save the location. To tune to a PRESET station: Press and release the PRESET button to step through the PRESET stations.
Using Bluetooth
To enter the Bluetooth mode, press the button.
Pairing
- If no Bluetooth device is connected, Bluetooth pairing will begin automatically and the icon will flash on the display.
- The radio will continue to search for a signal for 3 minutes.
- While the is flashing, select “M12 Radio + Charger” on the Bluetooth-capable device.
- Once the device has successfully paired with the radio, the will be shown on the radio’s display.
Connecting
To enter the Bluetooth mode, press the button.
When the radio locates a paired Bluetooth device, the will stop flashing.
If the connection is lost between the radio and the Bluetooth device, the
radio will try to reconnect automatically for up to 3 minutes.
Controlling
When streaming music through to the radio via a Bluetooth device, use the
button. Use the ◄ and ► to move through the tracks.
CHARGER OPERATION
WARNING
Charge only MILWAUKEE M12™ Lithium-Ion battery packs in the MILWAUKEE Li-Ion
Battery Charger. Other types of batteries may cause personal injury and
damage. The battery pack and charger are not compatible with V™-technology or
NiCd systems.
When to Charge MILWAUKEE Li-Ion
Battery Packs
Remove the battery pack from the tool for charging when convenient for you and
your job. MILWAUKEE batteries do not develop a “memory” when charged after
only a partial discharge. It is not necessary to run down the battery pack
before placing it on the charger.
- Use the Fuel Gauge to determine when to charge your MILWAUKEE Li-Ion battery pack.
- You can “Top-Off” your battery pack’s charge before starting a big job or a long day of use.
How to Charge the Battery Pack
Plug the Radio + Charger into a 120V outlet. The battery packs will not charge
if the Radio + Charger is not plugged in. Place the battery pack onto the baby
sliding the pack on from the top of the bay. The red light will turn on,
either flashing (the pack is too hot or cold) or continuous (the pack is
charging).
-
A fully discharged battery pack with an internal temperature in the normal range will charge in about 30 to 185 minutes, depending on the battery pack.
-
Heavily cycled batteries may take longer to charge completely.
-
The Fuel Gauge lights on the battery pack are displayed as the pack is being charged, indicating how fully charged the pack is.
-
After charging is complete, the continuous green light will turn on and the fuel gauge will turn off.
-
The charger will keep the battery pack fully charged if it is left on the charger.
-
If the light indicator flashes red and green, check that the battery pack is fully seated in the bay. Remove the pack and reinsert.
If the problem persists, contact a MILWAUKEE service facility. -
If the light indicator does not come on, check that the battery pack is fully seated in the bay. Remove the pack and reinsert. If the light indicator still does not come on, contact a MILWAUKEE service facility.
Charging a Hot or Cold Battery Pack
The Red Flashing Indicator light on the charger indicates that the battery
pack temperature is outside the charging range.
Once the battery pack is within the acceptable range, normal charging will
take place and the red light will be continuous.
Hot or cold batteries may take longer to charge.
Li-Ion Charging Status
Battery Pack
Temperature| Red Charger
Indicator Light| Charging Status
Too Hot
Normal Range
Too Cold| Fast Flashing
Continuous
Fast Flashing| Not charging
Normal charging
Not charging
MAINTENANCE
WARNING
To reduce the risk of injury, always unplug the charger and remove the battery
pack from the charger or tool before performing any maintenance. Never
disassemble the tool, battery pack, or charger. Contact a MILWAUKEE service
facility for ALL repairs.
Maintenance and Storage
Store your charger in a cool, dry place.
As a general practice, it is best to unplug battery chargers and remove
battery packs when not in use.
No battery pack damage will occur, however, if the charger and battery pack
are left plugged in.
Changing Back-up Batteries
WARNING
Batteries may leak chemicals or may explode if used incorrectly.
The following care should be taken to prevent such an incident:
- Make sure the positive (+) and negative (-) battery terminals are positioned correctly.
- Do not mix new and old batteries together, or mix different types of batteries.
- Do not try to recharge non-rechargeable batteries.
If chemicals from the batteries come in contact with your skin, wash them off
immediately with water.
If chemicals leak onto the radio, clean the radio completely.
Choking hazard. Keep batteries away from children.
To hold station presets and clock time when the battery pack is removed and
the radio is unplugged, (2) AAA batteries are required.
- Remove the battery pack and unplug the radio.
- Remove the screw and battery cover located near the battery bay.
- Insert two (2) AAA batteries according to matching positive (+) and negative (-) marks.
- Replace the battery cover and screw.
- Always dispose of used batteries properly.
WARNING
To reduce the risk of fire, personal injury, and product damage due to a short
circuit, never immerse your tool, battery pack or charger in fluid or allow
fluid to flow inside them. Corrosive or conductive fluids, such as seawater,
certain industrial chemicals, and bleach or bleach-containing products, etc.,
can cause a short circuit.
Cleaning
Clean out dust and debris from charger vents and electrical contacts by
blowing with compressed air.
Use only mild soap and a damp cloth to clean the battery pack and charger,
keeping away from all electrical contacts. Certain cleaning agents and
solvents are harmful to plastics and other insulated parts.
Some of these include gasoline, turpentine, lacquer thinner, paint thinner,
chlorinated cleaning solvents, ammonia, and household detergents containing
ammonia.
Never use flammable or combustible solvents around battery packs, chargers, or
tools.
Repairs
For repairs, return the tool, battery pack, and charger to the nearest
authorized service center.
LIMITED WARRANTY
USA & CANADA
Every MILWAUKEE power tool* (see exceptions below) is warranted to the
original purchaser only to be free from defects in material and workmanship.
Subject to certain exceptions, MILWAUKEE will repair or replace any part on an
electric power tool that, after examination, is determined by MILWAUKEE to be
defective in material or workmanship for a period of five (5) years* after
the date of purchase unless otherwise noted. Return of the power tool to a
MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service
Station, freight prepaid and insured, is required. A copy of the proof of
purchase should be included with the returned product. This warranty does not
apply to damage that MILWAUKEE determines to be from repairs made or attempted
by anyone other than MILWAUKEE authorized personnel, misuse, alterations,
abuse, normal wear and tear, lack of maintenance, or accidents.
Normal Wear: Many power tools need periodic parts replacement and service to
achieve the best performance. This warranty does not cover repair when normal
use has exhausted the life of a part including, but not limited to, chucks,
brushes, cords, saw shoes, blade clamps, o-rings, seals, bumpers, driver
blades, pistons, strikers, lifters, and bumper cover washers.
This warranty does not cover Air Nailers & Staplers; Airless Paint Sprayer; Cordless Battery Packs; Gasoline Driven Portable Power Generators; Hand Tools; Hoist – Electric, Lever & Hand Chain; M12™ Heated Gear; Reconditioned Product; and Test & Measurement Products.
There are separate and distinct warranties available for these products.
**The warranty period for Job Site Radios, M12™ Power Port, M18™ Power
Source, Jobsite Fan, and Trade Titan™ Industrial Work Carts is one (1) year
from the date of purchase. The warranty period for the M18 FUEL™ 1″ D-Handle
High Torque Impact Wrenches, Drain Cleaning Cables, AIRSNAKE™ Drain Cleaning
Air Gun Accessories, and REDLITHIUM™ USB Laser Levels is two (2) years from
the date of purchase. The warranty period for the M18™ Compact Heat Gun, 8
Gallon Dust Extractor, M18™ Framing Nailers, M18 FUEL™ 1/2″ Ext.
Anvil Controlled Torque Impact Wrench w/ ONE-KEY™, M18 FUEL™ 1″ High Torque
Impact Wrench w/ ONE-KEY™, M18 FUEL™ 2 Gal.
Compact Quiet Compressor and M12™ Laser Levels is three (3) years from the
date of purchase. The warranty period for the LED in the LED Work Light and
the LED Upgrade Bulb for the Work Light is the lifetime of the product subject
to the limitations above. If during normal use the LED or LED Bulb fails, the
part will be replaced free of charge. Warranty Registration is not necessary
to obtain the applicable warranty on a MILWAUKEE power tool product. The
manufacturing date of the product will be used to determine Compact Quiet
Compressor, and M12 TM Laser Levels is three (3) years from the date of
purchase. The warranty period for the LED in the LED Work Light and the LED
Upgrade Bulb for the Work Light is the lifetime of the product subject to the
limitations above. If during normal use the LED or LED Bulb fails, the part
will be replaced free of charge. Warranty Registration is not necessary to
obtain the applicable warranty on a MILWAUKEE power tool product. The
manufacturing date of the product will be used to determine the warranty
period if no proof of purchase is provided at the time warranty service is
requested. ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES
DESCRIBED HEREIN IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY
MILWAUKEE PRODUCT. IF YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT
PURCHASE THE PRODUCT. IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY
INCIDENTAL, SPECIAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES, OR FOR ANY COSTS,
ATTORNEY FEES, EXPENSES, LOSSES, OR DELAYS ALLEGED TO BE AS A CONSEQUENCE OF
ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY PRODUCT INCLUDING, BUT NOT LIMITED
TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME STATES DO NOT ALLOW THE EXCLUSION OR
LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR
EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES, WRITTEN OR ORAL. TO THE EXTENT PERMITTED BY LAW,
MILWAUKEE DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR
PURPOSE; TO THE EXTENT SUCH DISCLAIMER IS NOT PERMITTED BY LAW, SUCH IMPLIED
WARRANTIES ARE LIMITED TO THE DURATION OF THE APPLICABLE EXPRESS WARRANTY AS
DESCRIBED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED
WARRANTY LASTS, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY
GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY
FROM STATE TO STATE. This warranty applies to products sold in the U.S.A. and
Canada only. Please consult the ‘Service Center Search’ in the Parts & Service
section of MILWAUKEE’s website
www.milwaukeetool.com or call 1.800. SAWDUST
(1.800.729.3878) to locate your nearest service facility for warranty and non-
warranty service on a Milwaukee electric power tool.
ACCESSORIES
WARNING
Use only recommended accessories. Others may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetool.com or contact a
distributor.
SERVICE – UNITED STATES
1-800-SAWDUST (1.800.729.3878)
Monday-Friday, 7:00 AM – 6:30 PM CST
or visit www.milwaukeetool.com
Contact Corporate After Sales Service Technical Support with technical,
service/repair, or warranty questions.
Email:
metproductsupport@milwaukeetool.com
Become a Heavy Duty Club Member at
www.milwaukeetool.com to receive important
notifications regarding your tool purchases.
SERVICE – CANADA
Milwaukee Tool (Canada) Ltd
1.800.268.4015
Monday-Friday, 7:00 AM – 4:30 PM CST
or visit www.milwaukeetool.ca
MILWAUKEE TOOL
13135 West Lisbon Road
Brookfield, WI 53005 USA
58142951d2
08/20
01612800801Q-01(A)
Printed in China
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>