DYNATRAP DT2020XLP Full Acre – High Capacity Tungsten Insect Trap Owner’s Manual

June 6, 2024
DynaTrap

DYNATRAP DT2020XLP LED Owner’s Manual

DYNATRAP Logo

Thank you for purchasing the DynaTrap® Insect Trap!

This product may be covered by one or more U.S. patents or pending patent applications. See www.DynaTrap.com/patents

IMPORTANT: READ CAREFULLY IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO

PERSONS

WARNING: when using electric appliances, basic precautions should always be followed, including the following:

  1. Please read all instructions before using the DynaTrap® Insect Trap and keep for future reference.
  2. To disconnect, turn all controls to the off (“O”) position, then remove plug from outlet.
  3. To reduce the risk of injury from moving parts or electric shock, always turn unit off and disconnect plug before servicing or cleaning.
  4. Always unplug before replacing lamp. Replace with same type rated UV-LIGHT LED bulbs, DynaTrap® model 32020.
  5. Do not position the unit near heat, gas, oil or other flammable materials.
  6. Place out of reach from children.
  7. To reduce the risk of electrical shock, do not put appliance in water or other liquid.
  8. Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been dropped into water or other liquid.
  9. Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
  10. Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
  11. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
  12. Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
  13. Do not touch fan while in motion.
  14. Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from sharp edges.
  15. If using outdoors, use only extension cords with a tag stating, “Suitable for Use with Outdoor Appliances.”
  16. Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
  17. Only use attachments recommended or sold by the manufacturer.
  18. This appliance is provided with double insulation. Use only identical replacement parts. See instructions for Servicing of Double-Insulated Appliances.

INSTALLATION & OPERATING INSTRUCTIONS

  1. Unpack unit. Save carton for off-season storage (if needed). Remove cardboard insert from the retaining cage.
  2. Place the air damper assembly in the retaining cage with the crossbar facing up. Align the six damper notches with the matching notches on the retaining cage.
  3. Place the trap on the retaining cage and twist clockwise to the lock position.
  4. If hanging the unit, place it approximately 3 – 6 feet above floor or ground for optimal catch-rate and easy access for cleaning. Unit can also be placed on the floor or ground.
  5. Flip power switch to “ON” (“I”) position. The switch is located under the upper housing near the light bulbs.
  6. For best catch results, leave unit on at all times, except when cleaning or servicing.
  7. Catch rate activity will be higher at night. For best catch results, place unit away from other competing light sources.
  8. It is recommended to place the unit 20 – 40 feet away from where people will be sitting.
  9. This unit is all-weather resistant – designed for outdoor use including rainy conditions. Intended for household and commercial, indoor and outdoor use.
  10. INSTALLATIONTo reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way.
  11. SERVICING OF DOUBLE-INSULATED APPLIANCES – In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those parts in the appliance. A double-insulated appliance is marked with the words “DOUBLE INSULATION”, “DOUBLE-INSULATED” or the symbol:

FCC COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

USER MAINTENANCE INSTRUCTIONS – CLEANING

Frequent cleaning will prolong the life of the unit, ensure fire prevention and provide for more efficient operation.

  1. Remove the retaining cage by holding the trap securely and twisting counterclockwise.
  2. Grasp the edge of the crossbar and pull up firmly to remove damper assembly.
  3. Dispose of contents and clean any buildup from the inside of the retaining cage with a small brush.
  4. Attach the air damper assembly to retaining cage and reattach to trap with a clockwise twist to the lock position.
  5. Clean before off-season storage. IMPORTANT: DO NOT press or push against the screen windows while cleaning or assembling.

REPLACING BULBS

  • Replace With DynaTrap UV-LIGHT LED Bulb #32020 (or equivalent G5 Type – DC 12V/2.4W UVA Bulb)

The UV-LIGHT LED bulb life expectancy is approximately 20,000 hours (or about 2.25 years of continuous 24/7 operation). If you experience any trouble with your trap, please see troubleshooting.

  1. Turn power switch to “OFF” (“0”) position. UNPLUG UNIT (1), and allow bulbs to cool before replacing.
  2. Remove screw from clear plastic light socket covers (2).
  3. Remove both clear plastic light socket covers.
  4. Carefully turn bulb counterclockwise and then pull bulb straight out (3).
  5. Locate and insert new bulbs into sockets, carefully turn clockwise, and make sure the prongs of the bulb are seated properly.
  6. Replace clear plastic light socket covers and secure with screw.

REPLACING BULBS

HOW THE DYNATRAP® INSECT TRAP WORKS

HOW THE DYNATRAP® INSECT TRAP WORKSFlying insects are attracted to the unit by the UV light and CO2 that is generated by the photo-catalysis between the UV lamps and the special TiO2 coating. The fan then pulls the insects into the screened base, trapping them until they dehydrate and die. The base can be removed, allowing the contents to be periodically emptied into the trash. The see-through screen shows the insects trapped in the compartment, alerting you when the cage needs to be emptied.

TROUBLESHOOTING

TROUBLESHOOTING

LIMITED WARRANTY

DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

REPLACEMENT PARTS

32020 2, UV-LIGHT LED Replacement Bulbs, G5 Type – DC 12V/2.4W

o see all replacement and accessory parts available for your DynaTrap, visitwww.DynaTrap.com.

SAVE THESE INSTRUCTIONS

Dynamic Solutions Worldwide, LLC
69 N. Locust St., Lititz, PA
17543 1-877-403-8727 (TRAP)
dynatrap@woodstream.freshdesk.com
www.DynaTrap.com

FOR HOUSEHOLD AND COMMERCIAL, INDOOR AND OUTDOOR USE

Intertek Logo

This device complies with Performance Standards for Light-Emitting Products, 21 CFR, Part 1040, Chapter 1, Subchapter J, Radiological health.

© Dynamic Solutions Worldwide, LLC

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals