DYNATRAP DT1120 High Capacity Copper Insect Trap

IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS

WARNING

  1.  when using electric appliances, basic precautions should always be followed, including the following:
  2.  Please read all instructions before using the DynaTrap® Insect Trap and keep for future reference.
  3.  Always turn unit off and disconnect plug before servicing or cleaning.
  4.  To reduce the risk of injury from moving parts or electric shock, always turn the unit off and disconnect the plug when not in use and before servicing or cleaning.
  5.  Always unplug before replacing lamp. Replace with same type rated UV-LIGHT LED 2.4-Watt bulbs, DynaTrap® model 41020.
  6.  Do not position the unit near heat, gas, oil or other flammable materials.
  7.  Place out of reach from children.
  8.  To reduce the risk of electrical shock, do not put appliance in water or other liquid.
  9.  Never operate this product if it has a damaged cord or plug, if it is not working properly, if it has been dropped or damaged, or if it has been dropped into water or other liquid.
  10.  Connect only to a circuit that is protected by a ground-fault circuit-interrupter (GFCI).
  11.  Do not insert fingers or any foreign objects into the unit while it is connected to an electrical outlet.
  12. Collected insects within the unit may contribute to fire, so clean insects from the unit frequently.
  13.  Do not clean this product with water spray. Do not place where it can fall into water, or near flammable materials.
  14.  Do not touch fan while in motion.
  15.  Do not abuse cord—never carry or hang unit by cord or yank it to disconnect from receptacle. Keep cord away from sharp edges.
  16.  If using outdoors, use only extension cords with a tag stating, “Suitable for Use with Outdoor Appliances.”
  17.  Use only extension cords that have plug and receptacles that match the product plug. Replace or repair damaged cords.
  18.  Only use attachments recommended or sold by the manufacturer.
  19. This appliance is provided with double insulation. Use only identical replacement parts. See instructions for Servicing DoubleInsulated Appliances.

INSTALLATION & OPERATING INSTRUCTIONS

Unpack unit. Save carton for off-season storage (if needed).

  1.  If hanging or mounting the trap place approximately 3–6 feet above the floor/ground level for optimal catch rate and easy access for cleaning.
  2. If mounting the trap to a wall, secure the mounting bracket to a wall, fence, or other stationary surface using the mounting hardware (included). Then, mount the trap on the bracket by sliding the mounting channel on the side wall of the trap over the mounting bracket peg.
  3.  For best catch results leave unit on at all times, except when cleaning or servicing.
  4.  Catch rate activity will be higher at night. For best catch results it is recommended to keep the unit away from competing light sources.
  5.  It is recommended to place the unit at least 20 to 40 feet away from where people will be sitting.
  6.  This unit is all-weather resistant – designed for outdoor use including rainy conditions. Intended for household and commercial, indoor and outdoor use.
  7. To reduce the risk of electric shock, this appliance has a polarized plug (one blade is wider than the other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet. Do not change the plug in any way
  8. SERVICING OF DOUBLE-INSULATED APPLIANCES In a double-insulated appliance, two systems of insulation are provided instead of grounding. No grounding means is provided on a double-insulated appliance, nor should a means for grounding be added to the appliance. Servicing of a double-insulated appliance requires extreme care and knowledge of the system and should be done only by qualified service personnel. Replacement parts for a double-insulated appliance must be identical to those parts in the appliance. The symbol must be identical to those parts in the appliance. A double-insulated appliance is marked with the words “DOUBLE INSULATION”, “DOUBLE-INSULATED” or the symbol

FCC COMPLIANCE

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAUTION: Changes or modifications not approved by the party responsible for compliance could void user’s authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  •  Reorient or relocate the receiving antenna.
  •  Increase the separation between the equipment and receiver.
  •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

USER MAINTENANCE INSTRUCTIONS – CLEANING

  • Clean the trap at least once a week to prolong life of the unit, insure fire prevention, and provide for more efficient operation.
  •  Be sure to clean the unit once per week.
  •  Unplug before cleaning.
  •  For weekly cleaning, position the collection bag (not included) beneath trap and press top of button on the basket. Bottom of basket will open to release collected insects. Seal bag and dispose of in accordance with local regulations. Brush any remaining residue from basket door and push up until you hear the button click closed, and secure.
  •  For major cleaning, twist the basket clockwise to remove it from the upper housing. After removing, use a soft brush and remove any dirt and debris from the fan housing. Remove the damper assembly from the basket by grasping the crossbar and pulling up firmly. Remove any buildup from the inside of the basket and damper with a brush and replace damper by snapping firmly into place.  When replacing the retaining cage DO NOT press/push against the screen windows.

REPLACING BULB

  1. Replace With DynaTrap UV-LIGHT LED Bulb #41020 (or equivalent G24-Q2 Type – DC 12V/2.4W UVA Bulb)The UV-LIGHT LED light bulb life expectancy is approximately 20,000 hours (or about 2.25 years).
  2. UNPLUG UNIT, and allow bulb to cool before replacing.
  3. Remove screw (A). Twist cover counter-clockwise (B). Tilt cover back to expose bulb (C). Note: Upper and lower sections will remain connected by electrical wire – Do Not Pull or Attempt To Disconnect.
  4. Cover the bulb with a cloth to protect your finger and hand. Grasp the bulb (with your hand and fingers protected by the cloth) and gently pull the bulb from the socket.
  5. Remove any debris from the lamp socket with a brush before inserting the new bulb.
  6. Replace cover onto grill and twist clockwise to lock, replace screw and tighten to secure

DT1120-pic2

HOW THE DYNATRAP® INSECT TRAP WORKS

Flying insects are attracted to the unit by UV light and CO2that is generated by the photo-catalysis between the UV-LIGHT LED lamp and special TiO2 coating. The fan then pulls the insects into the screened base, trapping them until they dehydrate and die. The base can be removed, allowing the contents to be periodically emptied into the trash.

TROUBLESHOOTING

Problem: Possible cause: Correction:
Bulb does not illuminate and fan does not spin. No electrical power. 1.

Check plug, receptacle and fuse or circuit breaker.

2.  Check to make sure power is switched to the “ON” position.

Bulb illuminates, but fan does not spin.| Shorted fan.| UNPLUG UNIT: Examine fan to see that it is free from foreign material, dirt or buildup of dead insects.

Clean unit as in “CLEANING” section.

Fan spins, but bulb does not illuminate.| 1.  Bulb not seated properly

2.  Burnt out bulb

| 1.  Check socket for proper bulb seating and alignment.


2.  Replace bulb following instructions under “Replacing Bulb”

FOR HOUSEHOLD AND COMMERCIAL INDOOR AND OUTDOOR USE

LIMITED WARRANTY

DYNAMIC guarantees to the original purchaser that this product is free from defective materials and workmanship. This warranty is limited to remedy any defective part for a period of one year from date of original date of purchase. Retain your original receipt as proof of purchase. This warranty does not apply to the light bulb, nor to, in our judgment, misuse or abuse. If this unit has been  altered, no warranty is in force. This warranty does not apply if this unit is purchased outside the United States, excluding Canada and Mexico. In no case shall DYNAMIC be liable for any accidental, punitive, consequential, or any other damages of any kind for breach of this or any other warranty, expressed or implied, whatsoever. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights that vary from state to state.

This device complies with Performance Standards for Light-Emitting Products, 21 CFR, Part 1040, Chapter 1, Subchapter J, Radiological health.  Dynamic Solutions Worldwide, LLC 69 N. Locust St., Lititz, PA 17543 1-877-403-8727 (TRAP) dynatrap@woodstream.freshdesk.com www.dynatrap.com © Dynamic Solutions Worldwide, LLC This device complies with Performance Light-Emitting Products, 21 CFR,  Part 1040, Chapter 1, Subchapter J, Radiological health.

REPLACEMENT PARTS

41020 1, UV-LIGHT LED Replacement Bulb, G24-Q2 Type – DC 12V/2.4W
To see all replacement and accessory parts available for your DynaTrap, visit www.DynaTrap.com