Electric Lock User’s Manual
Model: ET24
TOPENS Website
http://www.topenstool.com/
C030426
VER 20b
Important Note:
-
The open delay time of the 2 actuators must be set to more
than 4S if the electric lock is used with a dual swing gate opener which is powered by the DPS180-U AC-DC power supply, or the gate opener would work improperly. -
Electric lock improves the safety of your gate, and it is highly recommended if you have animals or live in areas affected by strong winds when the gate is longer than 1.5 meters (7ft).
Electric Lock Part List
Important Information:
- Before you install the Electric Lock please be sure the gate is level, moves freely, and does not bind or block against barriers.
- On the Pull-to-Open installation, for the Electric Lock to work properly, in order to ensure the lock engages with the lock receiver firmly, the limit switch B must be moved outward a little bit more than the desired close position.
- The Electric Lock must be installed on the outside of the gate if on the Push-to-Open gate.
- Due to the various mounting conditions, mounting hardware is not provided. Read this manual carefully to determine the mounting hardware required for your condition.
- For dual gate, the lock must be installed on the Master Gate (gate 1) which is near the Control Box, and the lock receiver must be installed on the Slave Gate (gate 2).
( If the gate near the control box has been set up as slave gate, you can
change the settings following “User’s Manual” “Control Board Settings”
“Master/Slave Gate Set” )
Installation for Single Gate
Step 1:
Disengage the clutch of the opener with the Release Key. You can move the gate
by hand, so the gate can swing freely during the installation of the Electric
Lock.
Step 2:
With the gate in the closed position, determine the best location for the lock
and receiver. The lock and receiver must be level and aligned with the opener.
The lock and receiver should have a solid surface or tube fence to provide
stability.
Step 3:
For the Metallic Tube gate, if the thickness of the fence post is bigger than
or equal to 3mm, you can thread on the fence post, and fasten the lock and
receiver only using bolts (without nuts). Otherwise, drill holes throughout
the fence post, and fasten the lock and receiver with bolts, lock washers, and
nuts. Of course, you can weld them directly. For the Chain Link gate, you will
need U-Bolts, saddles, lock washers, and nuts for the lock and receiver.
Step 4:
Recheck the lock’s position and alignment, make sure the electric lock works
correctly.
Step 5:
Connect the lock’s power cables to the E-Plus board or the control
board of OPENS swing gate opener refers to the chapter “Wire Connection of
the LOCK” .
Note: Be sure that the clutch of the opener is engaged before you prepare to activate your opener (Use the Release Key).
|
---|---
Installation for Dual Gate
Step 1:
Disengage the clutches of the openers with the Release Key. You can move
the gates by hand, so the gates can swing freely during the installation of
the Electric Lock.
Step 2:
With the gates in the closed position, determine the best location for the
lock and receiver. The lock and receiver must be level and aligned with the
openers. The lock and receiver should have a solid surface or tube fence to
provide stability.
Step 3:
For Metallic Tube gates, if the thickness of the fence post is bigger
or equal to 3mm, you can thread on the fence post, and fasten the lock and
receiver only using bolts (without nuts). Otherwise, drill holes throughout
the fence post, and fasten the lock and receiver with bolts, lock washers, and
nuts. Of course, you can weld them directly. For Chain Link gates, you
will need U-Bolts, saddles, lock washers, and nuts for the lock and receiver.
Step 4:
Recheck the lock’s position and alignment, make sure the electric
lock work correctly.
Step 5:
Connect the lock’s power cables to the E-Plus board or the control
board of OPENS swing gate opener refers to the chapter “Wire Connection of
the LOCK”.
Note: Be sure that the clutches of the openers are engaged before you prepare to activate your openers (Use the Release Key).
|
---|---
Wire Connection of the Lock
- Wire Connection for A&AD&PW Series Swing Gate Opener The E-Plus board must be used with the E-Lock when it’s connected to the A&AD&PW swing gate opener. The E-Plus board is in the small box which is included in the package. J3 of the E-Plus board and the electric lock have the wiring connector. You can place the E-Plus board in the control box and then plug the J3 of the E-plus board to the electric lock directly. The other 2 set wires of the E-Plus board should be connected to the control board as the following wiring diagram or the wiring diagram in the manual of the gate opener. Wiring Diagram of the E-Lock to the A-Series Swing Gate Opener
Wiring Diagram of the E-Lock to the A-Series Swing Gate Opener
Wiring Diagram of the E-Lock to the AD &PW Series Swing Gate Opener
- Wire Connection of the Lock for KD 902 & AT1202 Series **Swing Gate Opener The E-Plus board is not needed to use with the two gate openers. The
electric lock can be wired to the “LOCK”** terminal directly, no matter the polarity of the wires.
NOTE: If the gate opener with which you want to use the lock is not
listed in the above diagram, you can find the wiring diagram in the user
manual of the gate opener or you can contact us to provide technical
support.
OPENS Website
http://www.topenstool.com/
Any questions, please do not hesitate to contact us:
E-mail: support@topenstool.com
Kindly include your Product Model, Purchasing Date & Site, Order #,
and your contact information. All your concerns will be replied within
24 hours.
Tel: +86 (571) 8908 0213 (China)
Mon-Fri 9:00AM-5:30PM (UTC +08:00)
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>