GE Appliances RAK149P2 Digital Programmable Wall Thermostat Owner’s Manual
- June 6, 2024
- GE Appliances
Table of Contents
- IMPORTANT SAFETY INFORMATION
- Specifications
- INTRODUCTION OVERVIEW
- INSTALLATION INSTRUCTIONS
- Configuration mode
- Operating functions
- Testing the thermostat
- Programming
- Low battery indicator
- Power failure Indicator
- Troubleshooting tips
- THERMOSTAT LIMITED WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
DIGITAL PROGRAMMABLE
THERMOSTATS
Owner’s Manual &
Installation Instructions
RAK149P2
View all GE APPLIANCES thermostat manual
GE is a trademark of the General Electric Company. Manufactured under
trademark license.
49-5000517 Rev. 2 10-20 GEA
IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING
WARNING
FIRE AND SHOCK HAZARD
- Always turn off power at the main power supply before installing, cleaning, or removing the thermostat. Failure to do so could result in an electrical shock hazard.
- Do not use voltages over 30 VAC. Higher voltages will damage the thermostat and could cause shock or fire hazards.
NOTICE
- All wiring must conform to local and national electrical and building codes.
- Use this thermostat only as described in this manual.
Specifications
Electrical rating:
- 24 VAC (18–30 VAC)
- 1 amp maximum per terminal
- 4 amp maximum total load
Operating temperature range: 40°F–99°F (4°C–37°C)
Temperature set range: 60°F–85°F (15°C–29°C)
Accuracy: ± 1°F (± 0.5°C)
System configurations:
- Factory Setting: 2-stage heat (heat pump/resistance heat), 1-stage cool, 1-speed fan
- Alternate Setting: 1-stage heat (resistance heat), 1-stage cool, 1-speed fan
Terminations: R, C, W, Y, G, B
Wiring: Maximum wiring length is 66ft (20 meters) for AWG18
The maximum wiring length is 60ft (18 meters) for AWG20
INTRODUCTION OVERVIEW
INSTALLATION INSTRUCTIONS
WARNING
| ELECTRICAL SHOCK HAZARD—Turn off the power by unplugging the unit or by removing the fuse or switching the appropriate circuit breaker to the OFF position before removing the existing thermostat. Failure to do so could result in risk of electric shock.
PACKAGE CONTENTS/ TOOLS REQUIRED
Package includes Thermostat on base, thermostat cover, 2 “AAA” batteries,
wiring labels, screws, and wall anchors. Tools needed: Drill with 3/16 bit,
hammer, screwdriver, and putty.
TO REMOVE THE EXISTING THERMOSTAT
- Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate circuit breaker.
- Remove the cover of the old thermostat. This should expose the wires.
- Label the existing wires with the enclosed wire labels before removing wires.
- After labeling wires, remove wires from wire terminals.
- Remove existing thermostat base from wall.
- Refer to the following section for instructions on how to install this thermostat.
TO INSTALL THERMOSTAT
IMPORTANT: Thermostat installation must conform to local and national
building and electrical codes and ordinances.
Note: Mount the thermostat about five feet above the floor. Do not mount
the thermostat on an outside wall, in direct sunlight, behind a door or in an
area affected by a vent or duct.
-
Turn off power to the heating and cooling system by removing the fuse or switching off the appropriate circuit breaker.
-
Move the Function switch on the thermostat to Off.
-
Remove the cover by inserting and twisting a coin or screwdriver in the slots on the top of the thermostat.
-
Put the thermostat base against the wall where you plan to mount it. Make sure wires will feed through the wire opening in the base of the thermostat.
-
With the base level, mark the placement of the mounting holes.
-
Set thermostat base and cover away from the working area.
-
Using a 3/16 drill bit, drill holes in the locations you have marked for mounting.
-
Use a hammer to tap supplied anchors in mounting holes.
-
Align the thermostat base with mounting holes and feed the control wires through the wire opening.
-
Seal holes for wires behind the thermostat with non-flammable insulation or putty, or use a wall plate obtainable from local hardware or home building store.
-
Use supplied screws to mount the thermostat base to the wall.
-
Insert stripped, labeled wires in matching wire terminals by pressing on the corresponding terminal contact. See the “Wiring Diagrams” section of this manual.
CAUTION Make sure the exposed portion of wires does not touch other wires. -
Gently tug wire to be sure of the proper connection. Double-check that each wire is connected to the proper terminal.
-
Insert two “AAA” batteries into the battery holder. Verify that they are oriented as shown on the battery holder.
-
Replace the cover on the thermostat by snapping it in place.
-
Plug the unit in or turn on the power to the system at the main service panel.
-
Test thermostat operation as described in the “Testing the Thermostat” section.
Wiring diagrams
Table 1: Terminals for five wires 1-stage heat/1-stage cool system
Note: Connect the G terminal of the thermostat to the Zoneline GL terminal for low fan speed or terminal GH for high fan speed. Only one can be selected.
Table 2: Terminals for six wires 2-stage heat/1stage cool system
Note: Connect the G terminal of the thermostat to the Zoneline GL terminal for low fan speed or terminal GH for high fan speed. Only one can be selected.
Configuration mode
The configuration mode is used to set the thermostat to match the
heating/cooling system. This thermostat will function with up to 2-stage heat
pump systems. To configure the thermostat, perform the following steps:
NOTE: The operation being set will blink in the display.
-
Slide the Function switch to the OFF position.
-
Simultaneously hold the and buttons in for 6 seconds while the thermostat is in OFF mode.
-
Press the or button to change settings within each screen.
-
Press the Hold button to advance to the next screen.
Note: The Mode button will return you to the previous screen. -
To save the changes and exit configuration mode, slide the Function switch to Heat or Cool.
Configuration Mode Settings
The setup screens for Configuration Mode are as follows:
-
Temperature Scale (F or C)—Choose Fahrenheit or Celsius.Press the or button to select. Press the Hold button to advance to the next screen.
NOTE: The default factory setting is Fahrenheit. -
Heat System— Check the model number on the GE PTAC chassis to determine the primary heating method.
AZ65H/95H are heat pumps and is the thermostat factory setting.
AZ45E/95E are electric heat models and will require a mode setting change.
To change the heating mode configuration, press the or button. Select HPV screen for heat pump or select ELE screen for electric heat.
Press the Hold button to advance to the next screen. -
Temperature Differential—Stage 1—(1–9°F) (1–5°C)
Set the number of degrees between the “setpoint” temperature and the “turn on” temperature for first stage. Press the : or button to set differential value.
Press the HOLD button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage. -
Temperature Differential—Stage 2 (1–9°F/1–5°C) Heat Pump (HPb) only
Set the number of degrees between when stage 1 turns on and stage 2 turns on. Press the: or button to set differential value.
Press the HOLD button to advance to the next screen.
Note: Default factory setting is 2°F/1°C for each stage. -
Minimum Cool Setpoint (60, 64, 66, 68, 70, 72, 74, 76°F) (15, 17, 19, 20, 21, 22, 23, 24°C)
Adjust to control the minimum Cool set temperature allowed. Press the or button to select.
Press the Hold button to advance to the next screen.
Note: Default factory setting is 60°F/15°C. -
Maximum Heat Setpoint (65, 70, 72, 74, 76, 78, 80, 85°F) (18, 21, 22, 23, 24, 26, 27, 29°C)
Adjust to control the maximum Heat-set temperature allowed. Press the or button to select.
Press the Hold button to advance to the next screen.
Note: Default factory setting is 85°F/29°C -
Room temperature offset (+9°F to –9°F) (+5°C to –5°C)
Adjust to calibrate displayed room temperature to match the actual room temperature. Press the or button to select.
Press the Hold button to advance to the next screen.
Note: Move the Function switch to Heat or Cool position to lock the settings into memory.
Note: Default factory setting is 0°F/0°C.
Operating functions
Off
- In this mode, the thermostat will not turn on the heating or cooling devices (a manual fan can operate).
- Off is also used to access Setup and Program modes.
Cool
- In this mode, the thermostat controls the cooling system.
- Press the Mode button to enter and exit the Program Cool mode.
- In Program Cool mode ( PROG displays), the thermostat will follow the program schedule that is stored in memory.
Heat
- In this mode, the thermostat controls the heating system.
- Press the Mode button to enter/exit the Program Heat mode.
- In Program Heat mode ( PROG displays), the thermostat will follow the program schedule that is stored in memory.
Hold
- When in Programmable Cool or Programmable Heat , you can lock in the present settings indefinitely by pressing the Hold button once ( PROG flashes). Press the Hold button again to leave Hold mode ( PROG solid). For a temporary Hold period, raise or lower the set temperature to desired set temperature. The thermostat will automatically return to the programmed set temperature after 2 hours.
Testing the thermostat
Once the thermostat is installed, it should be thoroughly tested.
CAUTION Do not use air conditioning when the outdoor temperature is below
50 degrees. This can damage the air conditioning system.
Note: Before testing the thermostat, move the Fan Auto/On switch to
the Auto position.
Fan Test
- With Function switch set to Off, slide Fan Auto/On switch to On position.
- The indoor fan turns on.
- Slide Fan Auto/On switch to the Auto position.
- Indoor fan turns off.
Cool Test
- Slide Function switch to Cool position. Cool mode screen is displayed.
- Adjust set temperature so it is 5 degrees below room temperature.
- Air conditioning should come on within a few seconds.
- Adjust the set temperature so it is 2 degrees above the room temperature and the A/C should turn off. Note: There is a 3 minute time delay and a 3-minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a minimum run time/off time delay).
Heat Test
- Slide Function switch to Heat position. Heat mode screen is displayed.
- Adjust the set temperature so it is 5 degrees above room temperature.
- Heat should come on within a few seconds.
- Adjust the set temperature so it is 2 degrees below the room temperature and the heat should turn off.
Note: There is a 3 minute time delay and a 3-minute minimum run time for the compressor when it turns on/off. (On some models, the fan may also have a minimum run time/off time delay).
Programming
Factory Programming Settings
The programmable thermostat comes preprogrammed with the following schedule:
MONDAY | MORN | 6:00 AM | DAY | 8:00 AM | EVE | 6:00 PM | NITE | 10:00 PM |
---|---|---|---|---|---|---|---|---|
through | HEAT | 70R F | HEAT | 62R F | HEAT | 70R F | HEAT | 62R F |
SUNDAY | COOL | 78R F | COOL | 85R F | COOL | 78R F | COOL | 82R F |
Setting the time and day of the week
The time and day of the week must be set for the program schedule to operate
correctly.
-
Slide the Function switch to the Off position.
-
Press the Hold button in for 6 seconds.
-
Press the or button to adjust the time in hours. Press the Hold button once. Now press the or button to adjust the time in minutes.
-
Press the Hold button while the time is displayed. The display shows the day currently set on the thermostat (01 = Monday, 02 = Tuesday, etc.).
-
Press the or button to set the current day of the week.
-
Press the Hold button to go to the programming schedule or slide the Function switch to Cool or Heat positions to lock the values into memory.
Program Overview
The programmable thermostat has four periods ( MORN, DAY, EVE, NITE ) that
are customizable for each day of the week. Each period will have a set time,
heat temperature, and cool temperature. The thermostat monitors the day and
time while maintaining the specific conditions that you have chosen for each
period in the program. Note: The operation being set will blink in the
display.
-
Place the Function switch in the Off position.
-
Press the Hold button for 6 seconds.
-
Press the Hold button 3 times.
• DAY (01–07) and PROG are displayed.
-
4. Press the or button to change the day you want to program (01-05 =Monday – Friday individually, 67 = program Saturday and Sunday at the same time, 17 = program every day of the week at the same time, 15 = program Monday – Friday at the same time).
-
Press the Hold button to advance to the next parameter.
• Period is displayed ( MORN, DAY, EVE, NITE ).
Note: You can always press the Mode button to return to the previous parameter. -
Press the or button to change the period of the day. The display should blink the period of the day.
-
Press the Hold button to advance to the next parameter.
• Set time is displayed. -
Press the or button to adjust hours. Press the Hold button once, and then press the or buttons to adjust minutes.
-
Press the Hold button to advance to the next screen parameter.
• Heat temperature is displayed (60°F to 85°F) / (15°C to 29°C).
Note: Transitions required after 11:59 PM must be programmed in the next days MORN period. -
10. Press the or button to adjust heat set temperature.
-
Press the Hold button to advance to the next screen.
• Cool temperature is displayed (60°F to 85°F) / (15°C to 29°C).
-
Press the < or > button to adjust the cool set temperature.
-
Press the Hold button to advance to the next screen.
Repeat steps 1–13 to program each day of the week individually.
Note: When programming is complete, slide the Function switch to Heat or Cool to exit Programming Mode.
Use the following personal program schedule to record your settings:
MONDAY 01
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
TUESDAY 02
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
WEDNESDAY 03
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
THURSDAY 04
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
FRIDAY 05
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
SATURDAY 06
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
SUNDAY 07
MORN| | DAY| | EVE| | NITE|
---|---|---|---|---|---|---|---
HEAT| | HEAT| | HEAT| | HEAT|
COOL| | COOL| | COOL| | COOL|
Low battery indicator
The programmable thermostats with battery backup have a low battery warning screen.
Low battery warning
The thermostat will display a low battery indication. The low battery
warning will beflashing until batteries are replaced.
Power failure Indicator
The programmable thermostats with battery backup also will indicate the main
power failure when the 24 VAC power from the room air conditioner is not
present.
Power failure
The thermostat will display a power failure indication ( “PF” ) on the
screen.
Note: If “ PF” is
displayed, it means the 24 VAC power to the thermostat is lost.
Notes
Troubleshooting tips
Problem | Solution |
---|---|
No Display | Check for 24 VAC at the thermostat and- batteries; the |
display is blank when 24 VAC is not present and batteries are bad.
System fan does not come on properly| Verify that the wiring is
correct.
All thermostat buttons are inoperative| Verify that 24 VAC is
present; the unit will not operate when 24 VAC is not present.
A thermostat turns on and off too frequently| Adjust temperature
differential (see Configuration Mode – Setting Temperature Differential,
Stage 1 and Stage 2 sections).
Program schedule activates at the wrong time| Check time (AM/PM)
set on thermostat (see Programming).
The thermostat does not follow the program| Verify that it is in
Program mode; PROG displays solid; check the time (AM/PM); check if in Hold
mode (PROG flashing)
PROG flashes (in Hold mode)| Press the Hold button to remove from
Hold mode
Fan runs continuously| Check Fan Auto/On switch. If set to ON position,
fan will run continuously.
The room temperature is not correct| Verify that the wall hole is
plugged with putty or insulation to prevent airflow from the wall cavity.
Adjust Temperature Offset (see Configuration Mode – Room temperature offset
section).
Compressor doesn’t run or turn off imme diately when changing
function or setting| There is a 3 minute time delay and a 3-minute
minimum run time for the compressor when it turns on/off.
The fan doesn’t run or turn off immediately when changing function
or setting| This is normal. On some models, the fan may have a minimum
run time/ off time delay.
displays on screen| Replace batteries with 2 fresh “AAA” alkaline
batteries.
“PF” displays on the screen.| Check for 24 VAC at the thermostat.
The display reads “12:00 PM”| Set clock/time
Problem not listed above| Press the Reset button once. Reset button
function: time, day, and mode will be changed to the factory settings. The
display is refreshed.
THERMOSTAT LIMITED WARRANTY
Staple your receipt here. Proof of the original purchase date is needed to validate the warranty.
For The Period Of GE Appliances Will Replace:
One Year
From the date of the original purchase
Full Replacement of the thermostat which fails due to a defect in materials or workmanship. For Warranty replacement, contact your distributor.
What GE Appliances Will Not Cover:
- Service trips to your location.
- Improper installation. If you have an installation problem, contact connections to the product.
- Failure of the product resulting from modifications to the product or due to unreasonable use, including failure to provide reasonable and necessary maintenance.
- In commercial locations, the labor is necessary to move the unit, after it has been initially installed, to a location where it is accessible for service by an individual technician; or, if the instructions included in this manual have been disregarded.
- Replacement of location fuses or the resetting of circuit breakers.
- Damage to the product caused by improper power supply voltage, accident, fire, floods, or acts of God. this thermostat.
EXCLUSION OF IMPLIED WARRANTIES—Your sole and exclusive remedy is product exchange as provided in this Limited Warranty. Any implied warranties, including the implied warranties of merchantability or fitness for a particular purpose, are limited to one year or the shortest period allowed by law.
This limited warranty is extended to the original purchaser and any succeeding
owner for products purchased for use within the USA and Canada. In Alaska, the
limited warranty excludes the cost of shipping or service calls to your site.
Some states or provinces do not allow the exclusion or limitation of
incidental or consequential damages. This limited warranty gives you specific
legal rights, and you may also have other rights which vary from state to
state or province to province. To know what your legal rights are, consult
your local, state, or provincial consumer affairs office or your state’s
Attorney General.
For service in Canada, contact your distributor.
Warrantor: GE Appliances, a Haier company Louisville, KY 40225
GE Appliances RAK149P2 DIGITAL PROGRAMMABLE Thermostat Installational Instruction
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>