Touch CI-DMX CI-DMX DMX Interface Module Instruction Manual
- June 1, 2024
- Touch
Table of Contents
Touch CI-DMX CI-DMX DMX Interface Module
Product Information
Specifications
- Product Name: DMX Fixture Driver
- Part Number: CI-DMX
- Input: DMX
- Output: DMX
- Mounting: DIN Rail (Included)
- End-of-Line Resistor Button: Not Required
Product Usage Instructions
Installation
- Ensure that the indicator LED is off before proceeding.
- Mount the DMX Fixture Driver on the included DIN Rail.
- Connect the DMX input cable from the DMX console or controller to the DMX input port on the device.
- Connect the DMX output cable from the device to the light fixtures.
- Terminate COM D1- and COM D1+ as per construction documents.
Branch Cable Types
Use Cat 5 cable (minimum) for branching. Do not connect to SmartNet or
SmartPacks.
Tips and Notes
- Use minimum Cat 5 cable and ensure cables are plugged into branch ports of room managers.
- If the device has communication, AC will be shown on the address display.
- For DMX input, ensure cabling meets DMX 512 electrical specifications and correct polarity.
- For DMX output, ensure cabling meets DMX 512 electrical specifications and correct polarity.
- If there is no communication with the device, communication LEDs will flash red/green.
FAQ
- Q: Where can I find support for the product?
You can reach out to Touché Controls at 2085 Humphrey Street, Fort Wayne, IN
- Contact them at 888.841.4356 or visit their website at ToucheControls.com.
INSTALLATION INSTRUCTIONS
**TOUCHÉ LIGHTING CONTROLS
** DMX INTERFACE
SIDE VIEW
DMX
SYMBOLS AS SHOWN ON SUBMITTAL AND CONSTRUCTION DOCUMENTS
TIPS / NOTES
- MINIMUM CAT 5 CABLE – ENSURE CABLES ARE PLUGGED INTO BRANCH PORTS OF ROOM MANAGERS – DO NOT CONNECT TO SMARTNET OR SMARTPACKS
- ADDRESS DISPLAY – IF DEVICE HAS COMMUNICATION “AC” WILL BE SHOWN
- DMX INPUT (CABLE RAN FROM DMX CONSOLE OR CONTROLLER) – RECOMMEND CABLING MEET DMX 512 ELECTRICAL SPECIFICATIONS – ENSURE POLARITY IS CORRECT
- DMX OUTPUT (CABLE RAN TO LIGHT FIXTURES) – RECOMMEND CABLING MEET DMX 512 ELECTRICAL SPECIFICATIONS – ENSURE POLARITY IS CORRECT
- COMMUNICATION LEDS FLASH RED/GREEN IF THIS IS NO COMMUNICATION WITH DEVICE
Touché Lighting Controls (a Product of ESI Ventures)