ALORAIR Sentinel HD55 Basement Crawl Space Dehumidifier User Manual
- June 6, 2024
- Alorair
Table of Contents
Restoration &Moisture &Ventilation
Sentinel HD55
Installation & Operations Manual
AlorAir Solutions INC.
Add: 2048 E. Francis St Ontario CA 91761
Tel: 888-990-7469
E-mail: sales@alorair.com
Warranty Registration
Congratulations on purchasing a new Sentinel Dehumidifier. Your new dehumidifier comes with an extended warranty plan. To register, simply fill out and return the warranty form provided in the dehumidifier box. Be sure to note your dehumidifier serial number as you will need it for registration.
Safety Notes
- The Sentinel Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all I liability reverts to the owner, and the warranty is voided.
- Sentinel Dehumidifiers should only be maintained and repaired by a qualified technician. . Sentinel Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
- Always unplug the dehumidifier before moving. . If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting. . To ensure proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12″ clearance and the discharge requires a minimum of 36″ clearance.
- The best option for proper diffusion of air throughout the room is to have the discharge blowing away from a wall and the inlet pulling air in parallel to a wall.
- Do not insert your fingers or any object into the inlet or discharge.
- All work on the dehumidifier should be done with the unit “off’ and unplugged.
- Do not use water to clean the exterior of the machine. To clean the unit, unplug from power, then use a damp cloth to wipe the exterior.
- Do not stand on the machine or use it as a device to hang clothes.
Identification
For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific machine.
Model Number: Sentinel HD55
Serial Number: Date of Purchase.
For additional questions concerning your dehumidifier, the following options
are available:
• Contact your installing contractor
• E-mail: sales@alorair.com
Electrical Supply
Power Supply: 115 V, 60 Hz AC, Single Phase Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp 240 Volts AC may cause serious injury from electric
shock. To reduce risk of injury: 1. Disconnect electrical power before
servicing 2. Only plug the unit into grounded electrical circuit 3. Do not use
an extension cord. 4. Do not use a plug adapter
WARNING:
Principle of Operation
The Sentinel Series Dehumidifier utilizes its integral humidistat to monitor
the conditioned space. When the relative humidity goes above the selected
setpoint, the dehumidifier will energize. Air is drawn across an evaporator
coil, which is cooler than the dew point of the air. This means moisture will
condense out of the air. The air is then reheated through the condenser coil
and distributed back into the room.
Installation
The area to be controlled should be sealed with a vapor barrier. If the unit
is installed in a crawlspace, all vents should be sealed.
WARNING:
Do not install your dehumidifier in a corrosive environment. Some liquid-vapor
barriers dry via “solvent evaporation”. Always make sure that the barrier is
completely dry and the area is thoroughly ventilated before installing a
dehumidifier.
Step #1: Place dehumidifier on a level surface. Do not place directly on the
vapor barrier. For example, use blocks, or pavers to create a level surface.
If the unit is handled in such a manner that the compressor did not remain in
the upright position, it is necessary to place it on a level surface and wait
a minimum of 2 hours before turning the unit “on”
NOTE: Sentinel HD55 Dehumidifiers can’t sit directly on the floor unless
the unit is feeding directly into a sump pump next to it. The elevation is
required to allow gravity flow of condensate water drain.
Step #2: Set Up Drain Line
The drain line should be routed to a suitable drain on the outside. It must
flow down to a drain without any loops, dips, or valleys.
Recommended Drain Option-Transition to PVC Pipe
- Cut a piece of 3/4″ OD PVC that is approx. 6″ long.
- Insert PVC into a 3/4″ elbow, then attach to a 3/4″ OD length of PVC to drain. (Note: Keep the length of PVC drain pipe to a minimum)
- Insert the open end of the tubing into the 3/4″ pipe so that it does not extend into the elbow fitting. For proper flow, a minimum downward slope of 1″ per 10′ run is required. (Note: If a proper downward angle is not possible, then it is recommended to use a Sentinel HDi90 which includes an integrated pump. Alternatively, you can use an external condensate pump).
- Support the PVC tubing so that it maintains a smooth downward flow to drain.
- Always test the drain before leaving the installation area.
Step #3: Plug unit into 15 amp grounded circuit.
Key Functions
-
Power Key
• Use this button to turn the dehumidifier on and off. Press once to turn the machine on. You will hear 2 beeps and the light will illuminate green. Press the power button a second time and you will hear one beep as the machine shuts down. Note that there is a one-minute fan delay on shut-down. -
Arrow Buttons
• Use the up and down arrow button to set the desired humidity setpoint on the display screen.
The setpoint can be any number between 36-90%. Creating a setpoint means that when the indoor humidity is lower than the setpoint, the machine will stop automatically. Conversely, when the indoor humidity is higher than the set level, the unit will operate.
NOTE: The humidity levels displayed are approximate only (+/- 5%) 3. Continuous Mode: Jr-
• To switch into the continuous mode, simply use the down arrow to set the humidity below 36%. The Cont. light should illuminate green on the display board to indicate that you have successfully switched into continuous mode. The display screen will show “CO”.
• When set to continuous, the dehumidifier will run constantly, regardless of the humidity level. To stop the machine, turn the unit off or switch back to normal humidistat operation. If you would like to switch back to normal humidistat operation, simply move the setpoint above 36%. -
Central Control
• This mode is not applicable on the Sentinel HD55. -
Auxiliary Terminals A5/A6
• The A5/A6 on the terminal strip can be used as a water level warning switch for external condensate pumps. If an external pump is connected, the pump must have a self-contained power supply and a water level signal line.
Indicator Lights
-
Humidity Display Screen
• The display screen has two functions:
1. When the unit is powered on, it shows the humidity of the space.
2. While setting the desired humidity level, the screen will show the set humidity. After a brief delay, the display will revert to the current humidity level. -
Power Indicator Light
• This light indicates that the unit is properly powered on and ready to operate. Always make sure the unit is “off” prior to performing any service. -
Continuous Mode/AutoDefrost Light
• When this light illuminates green, it indicates that the dehumidifier is set to the continuous operation mode.
• When the light glows red, it means the unit is in auto defrost mode and clearing the evaporator coil of any ice buildup. -
Compressor Light
• When the compressor light glows red, it indicates the compressor has been initiated but is currently warming up.
• Once the compressor light switches to green, it indicates the compressor is in working status.
Remote Control Instructions
Sentinel Dehumidifiers can be controlled using an optional remote accessory.
The Sentinel Remote Control connects to your Sentinel Series Dehumidifier via
a 25′ CAT 5 cable. The remote control contains an integrated sensor that gives
you multiple options for remotely controlling your unit, in addition to
monitoring the conditions surrounding the dehumidifier.
One application for the remote control is to install the dehumidifier in one
room with the conditioned air ducted into a second room that contains the
remote. For example, the dehumidifier could be installed in a laundry room and
ducked into a living room. The remote would then be mounted in the living room
so the remote sensor can control the humidity and provide easy controls for
the user.
Another useful application for the remote control is if the dehumidifier is in
an area that’s difficult to access on a regular basis.
For instance, if your dehumidifier is installed in your crawl space, the
remote could be mounted in your living space or garage. This provides you with
an easy way to monitor the dehumidifier.
-
Angul (Power)Button
Press the on/off button and the machine will start running (one beep). Press the button again to turn the machine off. -
Up Button / Down Button
• Use the Up and Down arrow buttons to adjust the humidity level. -
Mode M
Use the Mode button to switch between dehumidification and a ducted application.
• The symbol on the display board indicates the sensor on the remote control Is being utilized. ONOS
• The symbol on the display board Indicates the sensor on the dehumidifier is being utili ed. -
Temperature T
Press the temperature button to display the current temperature on the screen. Press the button again to turn off the display. -
Continuous C
Press this button to switch the unit into continuous mode. Cant. will appear on the display to indicate continuous mode. -
Drain Pump P
Use this button if the unit will not be in use for an extended period of time. Pressing the drain pump button will remove water from the pump reservoir, so the unit can be safely moved or stored. THIS FUNCTION IS ONLY AVAILABLE ON THE Sentinel HDi90 model.
NOTE: Symbols indicated above will only appear when the dehumidifier is powered on.
Operating Instructions
-
Start the Machine
Press the power key to turn the machine on. -
Adjust the Settings
Use the up and down arrow keys to adjust your desired setpoint (typically 50-55%). 3 -
Stop the Machine
Press the power key again and the machine will stop.
Note the fan will continue to operate for 1 minute after the unit has turned off.
NOTE: Do not disconnect the power cord to force the unit to stop. Always use the power button. -
Water Drainage
During normal operation, the Sentinel HD55 will automatically drain by the force of gravity. If you want to move or store your machine, wait at least 10 minutes to allow the machine to completely defrost, then lean the unit gently towards the drain to ensure that it is completely drained.
Sentinel HD55 Diagram
Front View
Back View
Maintenance
WARNING : Always unplug the unit before doing any maintenance.
Cleaning the machine body
Use a soft damp cloth to clean the exterior of the unit. Do not use any soap
or solvents.
Cleaning the filter
- Unplug the unit.
- Slide out the filter.
- Clean the filter mesh by vacuuming or washing with warm water (no soap or solvents).
- Be sure the filter is completely dry before restarting the unit.
Coil Maintenance
- Once per year, clean the coils with an approved coil cleaner
- Coil cleaner should be a self-rinsing, foaming cleaner such as WEB® Coil Cleaner.
Dehumidifier Storage
If the unit will be stored for an extended period of Ime, complete the
following steps:
- Turn off the unit and allow it to dry
- Wrap and secure the power cord.
- Cover the filter mesh.
- Store in a clean, dry space.
Ducted Applications
Ducting the dehumidifier allows the unit to be in one room while conditioning
an adjacent room. The supply grille is designed for 6″ flex ducting. Be sure
to secure the ducting with a tie wrap. Also, keep in mind that the supply
ducting can be screwed into an adapter if necessary.
Ducting Installation
• Maximum length for ducting= 6′
Note: The supply duct adapter is standard on all units
Removing Supply Duct Adapter
If it is necessary to remove the adapter, place your hand at bottom of the
adapter and use your fingers to pull out and down on the base of the adapter.
This will lift hooks out of cover holes.
Installing Supply
Duct Adapter
To install the adapter, line up with holes on the side of the unit and push up
from the base of the adapter.
Flex Duct
Installation
Rotate the flex duct counter-clockwise
Flex Duct Installation
Rotate flex duct clockwise
Troubleshooting
Symptom
| Cause|
Solution
---|---|---
Machine Won’t Run| Power Supply| Verify that there is power to the outlet and
that the plug is properly installed in the outlet
Room Temperature Over 1050, (Display HI) or Below 33°, (Display LO)| The unit
is outside the operating temperature range. Modify the room conditions so the
temperature is between 33*
•105°, and the operation will commence.
Low Air Flow| Air Filter is Clogged| Clean the filter mesh according to the
instructions listed in the manual.
Air Inlet or Outlet is Blocked.| Clear the blockage from the inlet or outlet.
Loud Noise| Machine Is Not Level| Move the dehumidifier to flat, firm ground.
Filter Mesh is Blocked| Clean the filter mesh according to the instructions
listed in the manual.
Trouble Code E:1| El =Humidity Sensor Issues| Check to ensure that the wire is
connected at both ends. If no issues are visible, the sensor may be faulty.
Trouble Code: HI or LO| Room Temperature Over 105°, of Below 33°
• (Display LO)| The unit is outside the operating temperature range. Modify
the room conditions so the temperature is between 33•105°gend operation will
commence. If room conditions are within the temperature range, replace the
defective sensor.
Sentinel HD55 Spare Parts
All Sentinel Models-Parts
Part#
|
Description
S-100| Remote Control Package(cable+remote)
S-101| Remote Control
S-102| Remote Control Cable,25′
S-107| Flexible Supply Duct,72″
S-108| Main Control Board
S-109| Display Board
S-110| RH/Temperature Sensor
Sentinel HD55-Parts
Part#| Description
S-500| Fan Motor
S-501| Complete Fan Assembly
S-502| Fan Capacitor
S-503| Compressor
S-504| Compressor Capacitor
S-505| Coil Assembly
S-506| Hot Gas Bypass Coil
S-508| RH/Temperature Sensor Cable
S-509| Display Cable
S-510| CAT 5 Prot Internal Cable
S-513| Foot, adjustable
Sentinel HD55-Filters
Part#| Description
S-517| MERV-8 Filter
S-518| HEPA Filter
S-519| Carbon Filter
Limited Warranty
All warranty benefits apply to the original owner only. Warranty cannot be
transferred or assigned.
1 YEAR (FROM DATE OF PURCHASE): AlorAir warrants the dehumidifier will operate
free of defects in workmanship and materials. At its discretion, AlorAir will
repair or replace any malfunctioning components, free of charge (excluding
transportation costs)
3 YEARS (FROM DATE OF PURCHASE): AlorAir warrants the refrigeration circuit
(compressor, condenser, and evaporator) will operate free of defects in
material or workmanship. At its discretion. Abram will replace defective
parts. including factory labor or refrigerant. This does not include
transportation.
5 YEARS (FROM DATE OF PURCHASE): AlorAir warrants the compressor, condenser,
and evaporator will operate free of any defects in material or workmanship. At
its discretion. AllerAir will repair or replace the defective parts. This does
not include labor, transportation, or refrigerant.
CUSTOMER RESPONSIBILITIES: In order to take advantage of the warranty service,
the customer must do the following:
1. Customer must provide normal care and maintenance (including, but not
limited to cleaning filters, coils, and pumps)
2. Removal and re-installation of the unit is the sole responsibility of the
owner.
3. If the customer cannot return unit to certified repair center, all costs
associated with freight shipment are borne by the customer. In addition, all
duties related to freight shipments, including but not limited to palletizing.
wrapping, labeling. and pickup is associated with customers.
4. If shipped, the customer is responsible for all risks of loss or damage.
AllerAir Warranty Steps:
- 0nce goods are received customers must log in www.alorair.com to fill out the warranty registration form and submit it to AlorAir company. We will receive your purchasing and installation information and save it. If no warranty registration is sent to us, the warranty period will begin the day the shipment left the warehouse. Please be sure to record serial # and date of installation. You will need this information to receive the RA number.
- If warranty service is necessary, customers must contact AlorAir Tech Support by sales@alorair.com or local technical service phone to receive a Return Authorization (RA number). Once an RA has been issued, customers should bring the unit to a certified repair center. AllerAir will arrange the shipping to bring the unit back to the Alorair warehouse (at the expense of the customers) if customers are not available.
- After the unit has been received by Alorair (whether at a repair center or the warehouse), Alorair will have an initial inspection. If it is determined to be an invalid warranty claim (see exclusions below), customers have to pay for all associated repair costs and shipping costs for units repair.
- Customers can pick up the unit after repair at their own expense for shipping. Units will have rigorous testing before sending it back to customers.
- If the unit can no longer be fixed, and it is in the warranty period and determined to be a valid claim, we will ship the customer a new unit within the same year warranty from the date of replacement.
- After parts are repaired or replaced by AlorAir, the original warranty period continues to apply until it meets its deadline. No extensions to the original warranty period.
Limited Warranty Exclusions
EXCLUSIONS:
DAMAGE DUE TO THE FOLLOWING IS NOT COVERED UNDER WARRANTY
-
ACTS OF NATURE- INCLUDING BUT NOT LIMITED TO:
• FLOODING
• FIRE WATER DAMAGE HURRICANE/STORM DAMAGE -
IMPROPER USAGE- INCLUDING BUT NOT LIMITED TO:
• POOL/SPA/TUB APPLICATIONS
• MISUSE. ABUSE, OR TAMPERING WHETHER INTENTIONAL OR ACCIDENTAL IMPROPER INSTALLATION OR DESIGN IMPROPER VOLTAGE LACK OF NORMAL CARE FAILURE TO FOLLOW INSTRUCTIONS -
CORROSION
-
FREEZING
-
ANY ADDITIONAL COSTS DUE TO CHANGES IN LAWS OR BUILDING CODES
-
FREIGHT CHARGES
-
ANY COSTS DUE TO LOST PROFIT OR DELAY
-
DAMAGE TO PROPERTY
-
CAUSE BEYOND CONTROL
-
CONSUMABLE PARTS, INCLUDING BUT NOT LIMITED TO:
• FILTERS
• BATTERIES POWER CORDS VALVES SWITCHES RUBBER PARTS -
DIRECT. INDIRECT, COLLATERAL, OR INCONSEQUENTIAL DAMAGES OF ANY KIND
THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES
EXPRESSED OR IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Alorair’s total
liability, regardless of nature of claim shall not exceed the original
purchase price of the product if a product or component is replaced while
under warranty, the applicable warranty period shall not be extended beyond
the original warranty time period.
The foregoing shall constitute the total liability of the seller in the case
of defective performance of all or any of the equipment or services provided
to the buyer, buyer agrees to accept and hereby accepts the foregoing as the
sole and exclusive remedy for any breach or alleged breach of warranty by
seller.
Any dishonesty or fraud in connection with Abrair warranty thoroughly voids
all warranty policies. Abrar expressly reserves the right to pursue legs
action in the event of dishonesty, fraud, or attempted fraud.