WARNING!
Please note that the CleanShield 550 should only be used with parts approved
by AlorAir. The use of unauthorized parts or alterations to the machine could
void your warranty. Contact an approved distributor for further assistance.
To Avoid the Risk of Fire or Electric Shock:
- Unit must be electrically grounded
- Insert 3-prong plug directly into outlet with Ground Fault Circuit Interrupting device.
- Do not use an adapter with this unit.
- Do not use the unit in standing water.
- If electrical parts get wet, they must be dried prior to use.
INTRODUCTION
The CleanShield HEPA 550 is a convenient filtration system that cleans the
air. The 550 uses an effective blend of air flow and advanced filtration to
expel airborne particles like mold spores, dust, pollen, and pet dander. The
CleanShield is ideal for for restoration jobs, including water, sewage, and
fire.
IDENTIFICATION
Congratulations on purchasing a CleanShield 550 air scrubber. In order to take
advantage of the warranty plan, be sure to note the serial number and date of
purchase.
Serial Number Date of Purchase.
HOW IT WORKS
- When set to maxiumum airflow, the 550 draws air through two types of filters- a pre-filter and a the HEPA/Activated Carbon Filter.
- The first phase of filtration, the prefilter, catches the large particles, while the second phase of filtration, the HEPA/Activated Carbon Filter, catches smaller particles, down to 0.3 microns.
SPECIAL FEATURES
Daisy-Chain Capability
Using the auxiliary outlet on the control panel, you can link up to 3 units
together, creating a maximum airfow 550 CFM. You can also daisy-chain the
machines when they are stacked vertically (limit of 2 units).
Multi-Positional
The CleanShield HEPA 550 can be operated in the vertical postion, as well as,
when stacked vertically (up to 2 units). When storing, the machines can be
stacked horizontally to save space.
Removable Intake Panel
The CleanShield 550 is equipped with a removable panel on the intake side of
the machine. The removable panel is quite useful in remediation applications,
so you can draw air out the room and create more negative pressure (use a
manometer to monitor air pressure). To use panel: 1. Remove the panel. 2.
Install the machine outside the containment area to draw air out. 3. Cut a
hole in the containment plastic that is the size of the unit’s inlet. 4.
Insert the inlet into plastic and seal the circumference tightly with duct
tape.
KEY FEATURES
INSTRUCTIONS
SETUP
- Place the CleanShield HEPA 550 so that it is in the upright, vertical position.
- Plug the machine into a standard 115 volt outlet. Note: Each unit needs 3 amps to operate.
- Power the unit on and adjust the speed by turning the variable speed control. The maximum speed is 550 CFM and the minimum speed is 270 CFM
- The CleanShield 550 can be operated in the vertical or horizontal postion, depending on the exact situation. At this point, adjust the machine to the optimal position.
THE CONTROL PANEL
Variable Speed Control The Variable Speed Control is used to adjust the power
of the machine. Turn the knob in a clockwise direction, to increase the speed
from maximum to minimum .The minimum speed setting is located immediately
under the OFF button. You can switch to minimum speed by turning the knob
counterclockwise.
Auxiliary Outlet
If more air filtration is necessary for a space, you can “daisy chain” or link
up to 3 CleanShield 550’s to the same outlet. There is a maximum amperage of
12 when the units are turned off, a maxium of 9 amps when the units are tumed
on. Other equipment can be plugged into the same outlet as the CleanShield as
long as it doesn’t go above the max amperage.
Circuit Breaker Switch
The Circuit Breaker Switch protects the unit if there are more than 12 amps of
electricity passing the circuit. If this occurs, the switch will cut off the
power to the unit.
CHANGING THE FILTERS
- Loosen the 4 locks that hold the filter board in place. 2. Slide out the filter panel board.
- Remove the used filters and replace with new filters.
WARNING
- Always wear approved protective gear when changing the filters.
- Filters should be changed after each remediation job
- If the indicator light is on, always change the HEPA/Activated Carbon Filter
APPLICATIONS
Water Damage In this application, the CleanShield should be placed in the
center of the affected area. The air scrubber will draw in the air, filter it,
then blow out the newly cleaned air. To begin the process, simply turn on the
scrubber and it will start cleaning the air. Keep in mind that if you are
working in a large area or one divided by walls, you may need several air
scrubbers to effectively clean the air.
Odor Control
The CleanShield 550, when used with the HEPAiActivated Carbon Filter, is
excellent at odor control, as well. Simply place the carbon filter in the pre-
filter slot and it will capture a wide variety of odor-causing gas molecules,
such as volatile organic compounds (VOC’s), smoke, soot, and paint fumes.
Other Uses The CleanShield is also useful in many other applications including
mold remediation, fire damage, dust control, and sewage remediation.
WARNING!
Breathing Hazard
- When using the CleanShield HEPA 550 in a containment area, always turn off power to open combus-tion appliances, such as firelaces, furnaces, water heaters, and HVAC systems, to avoid the risk of backdrafting carbon monoxide fumes.
- If the Filter Change Light illuminates during the remediation process, immediately change the HEPA/Activated Carbon Filter,
Tipping Hazard
- Use caution when stacking units,
- Do not stack more than 2 units on top of each other.
- Falling equipment could cause bodily harm.
SAFETY NOTES
- Always unplug the unit prior to performing any maintenance.
- Check the power cord for damage (fraying, cuts, etc.) before use.
- Verify that the GFCI outlet is working by powering on the machine and pressing the red GFCI test button. If the outlet is working, the “reset” button will pop up. To operate, press the reset button again.
- To avoid electric shock, never use a water hose or pressure washer to clean the electrical components.
- Check the pre-filter prior to operating the machine to ensure it is not clogged. If there is any sign of air flow restriction change the filter.
- Make sure the unit is dry prior to installing clean filters.
- When using the CleanShield for remediation purposes, replace both filters at the same time and always clean machine in between jobs. This will help prevent cross contamination.
LIMITED WARRANTY
This limited warranty starts from the date of purchase. Alorair Solutions Inc.
warrants to the original purchaser that this ALORAIR product is free from
manufacturing defects in material or workmanship for the limited warranty
period of:
Six (6) Month parts and labor. This includes the shipments charges for
replacement parts or units. One (1) year parts and labor. The shipment fee to
send the unit back to the manufacturer is not covered. Ten (10) years.
Polyethylene body ONLY.
This limited warranty is valid only on products purchased from the
manufacturer or ALORAIR authorized dealer and operated, installed, and
maintained according to the instructions included in this user guide or
furnished with the product. Alorair Solutions Inc will not provide in-home
service during or after the warranty period. You may be responsible for the
shipping charge to bring the product to the manufacturer for service. To
receive warranty service, the purchaser must contact ALORAIR at
888-990-7469 or
support@alorair.com. Proof of purchase or order
number is required to receive warranty service. During the applicable warranty
period, a product will be repaired or replaced at the sole option of ALORAIR.
Limited Warranty Exclusions:
This limited warranty covers manufacturing defects in materials or workmanship
encountered in a normal household, commercial or noncommercial use of this
product and shall not cover the following:
- Damage occurs in uses for which this product was not intended for.
- Damage caused by unauthorized modification or alteration of the product.
- Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
- Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
- Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
- Damage caused by failure to perform proper maintenance of the product.
- Damaged caused by not using the required filters for operation. (Pre-filter, HEPA & Activated Carbon Filter)
- Damaged caused by using in a high humidity environment (75% or higher).
- Damaged caused by using next to combustible materials/equipment that may or may not produce carbon monoxide.
Wiring Diagram
READ AND SAVE THESE INSTRUCTIONS
AlorAir Solutions INC.
Add: 14752 Yorba Ct Chino CA 91710 US
Tel:888-990-7469
E-mail:sales@alorair.com