Speaker Layout
The layout of the speakers should be planned before installation begins.
Layout starts in one corner of the room. The first speaker should be
positioned from each wall a distance approximately equal to the ceiling height
of the room.
The next speaker in row 1 should be spaced a distance approximately equal to
twice the height of the ceiling. Each additional speaker in the row should use
this same spacing.
Row 2 starts at twice the ceiling height distance from row 1 and twice the
ceiling height from the wall. The other speakers in this row are also spaced
at twice the ceiling height.
Row 3 is again spaced at twice the ceiling height from the previous row. The
first speaker starting this row is positioned at one ceiling height distance
from the wall (similar to row 1).
Continue this pattern of alternating rows until the room is covered.
The spacing of the speakers can be adjusted so that the speakers are evenly
spaced in a row and aesthetically pleasing.
Additional Hardware Accessories
© 2017 Bogen Communications, Inc.
All Rights Reserved.
Specifications subject to change without notice.
740-00002A 1704
Speaker Installation
STEP 1 – Remove the tile from ceiling and center the TB8 tile bridge on
the back. Use the tile bridge to trace out, and then cut an 8-1/2” square
hole.
NOTE : It can be more efficient to stack multiple ceiling tiles and then
cut the speaker opening in a number of them at one time.
STEP 2 – If using the optional RE84 Recessed Enclosure, bend up the 4 horseshoe tabs ( Figure 1 ) on the TB8. Position the TB8 over the hole in the tile and push down locator tabs ( Figure 2 ).
STEP 3 – Using the 4 supplied screws, attach the S810QIP to the TB8 using
the 4 clips in the corners of the opening on the TB8 as nuts. To complete the
Speaker Connection see STEP 6: Figure 3.
NOTE : Only tighten the screws until the grille is snug against the tile.
Over tightening will cause the screws to dimple the grille.
STEP 4 – If using the RE84 Recessed Enclosure, install an entry fitting to a knockout in the RE84 to accommodate the Category 5 or higher plenum rated network cable. Feed cable through the RE84 entry and clamp. To complete the speaker connection see S TEP 6: Figure 3.
STEP 5 – Place the entire assembled ceiling tile back into the ceiling
grid.
NOTE : Please refer to the Quantum Multicom IP “VoIP Speakers
Configuration and Operations Manual” for detailed instructions on how to
configure these speakers in the system.
Speaker Connection
STEP 6 – Make the electrical connections using Category 5 or higher
Ethernet cable with an RJ-45 connector. It is recommended to use shielded
Category 5 or higher Ethernet cable. If it is not available add the clamp-on
ferrite bead that is located in the installation kit to the Ethernet cable and
secure it with the wire tie to the speaker cage ( Figure 3 ).
The power is supplied by PoE using an 802.3af compliant network switch or PoE
injector.
Additional Accessories
STEP 7 – When using the S810QIPPG8U with a CA15 Call Switch, make the connection to the Quantum VoIP Module TEL/W PRIV connector as shown in Figure 4 ; the RED wire connects to the “ T ” pin and the BLACK wire to the “ R ” pin using the included 3-Pin Dinkle wire terminal connector.
NOTE : LINE OUT Connector -This function is reserved for future use.
Compliance
NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference; in which case, the user will be required to correct the interference at his own expense.
Warranty Information
Limited Warranty; Exclusion of Certain Damages
The S810QIPPG8U is warranted to be free from defects in material or workmanship for three (3) years from the date of sale to the original purchaser. Any part of the product covered by this warranty that, with normal installation and use, becomes defective will be repaired or replaced by Bogen, at our option, provided the product is shipped insured and prepaid to: Bogen Factory Service Department: 4570 Shelby Air Drive, Suite 11, Memphis, TN 38118, USA. The product(s) will be returned to you freight prepaid. This warranty does not extend to any of our products that have been subjected to abuse, misuse, improper storage, neglect, accident, improper installation or have been modified or repaired or altered in any manner whatsoever, or where the serial number or date code has been removed or defaced.
THE FOREGOING LIMITED WARRANTY IS BOGEN’S SOLE AND EXCLUSIVE WARRANTY AND THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY. BOGEN MAKES NO OTHER WARRANTIES OF ANY KIND, EITHER EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED AND EXCLUDED TO THE MAXIMUM EXTENT ALLOWABLE BY LAW. Bogen’s liability arising out of the manufacture, sale or supplying of products or their use or disposition, whether based upon warranty, contract, tort or otherwise, shall be limited to the price of the product. IN NO EVENT SHALL BOGEN BE LIABLE FOR SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOSS OF PROFITS, LOSS OF DATA OR LOSS OF USE DAMAGES) ARISING OUT OF THE MANUFACTURE, SALE OR SUPPLYING OF PRODUCTS, EVEN IF BOGEN HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSSES. Some States do not allow the exclusion of limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from State to State.
Products that are out of warranty will also be repaired by the Bogen Factory Service Department — same address as above or call 201-934-8500. The parts and labor involved in these repairs are warranted for 90 days when repaired by the Bogen Factory Service Department. All shipping charges in addition to parts and labor charges will be at the owner’s expense. All returns require a Return Authorization number.
7/2014
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>