Product Introduction
Overview
EM300 series is a sensor mainly used for outdoor environment through wireless
LoRa network. EM300 device is battery powered and designed for multiple
mounting ways. It is equipped with NFC (Near Field Communication) and can
easily be configured by a smartphone.
Sensor data are transmitted in real-time using standard LoRaWAN® protocol.
LoRaWAN® enables encrypted radio transmissions over long distance while
consuming very little power. The user can obtain sensor data and view the
trend of data change through Milesight IoT Cloud or through the user’s own
Network Server.
Features
- Up to 11 km communication range
- Easy configuration via NFC
- Standard LoRaWAN® support
- Milesight IoT Cloud compliant
- Low power consumption with 4000mAh replaceable battery
Hardware Introduction
Packing List
If any of the above items is missing or damaged, please contact your sales representative.
Hardware Overview
Front View
1. NFC Area
Bottom View
2. Vent
3. Waterproof Connectors
(For water leakage and magnet switch sensor)
Dimensions (mm)
Power Button
Note: The LED indicator and power button are inside the device. Switch on/off and reset can also be configured via NFC.
Function
| Action|
LED Indication
---|---|---
Turn On
| Press and hold the button for more than 3 seconds.|
Off → On
Turn Off
| Press and hold the button for more than 3 seconds.|
On -> Off
Reset
| Press and hold the button for more than 10 seconds.|
Blink 3 times.
Check On/Off Status
| Quickly press the power button.|
Light On: Device is on.
Light Off: Device is off.
Operation Guide
NFC Configuration
EM300 series can be configured via NFC.
-
Download and install “Milesight ToolBox” App from Google Play or Apple Store.
-
Enable NFC on the smartphone and open “Milesight ToolBox” App.
-
Attach the smartphone with NFC area to the device to read basic information.
-
Basic information and settings of devices will be shown on ToolBox if it’s recognized successfully. You can turn on/off the device by tapping the button on the Device Status. In order to protect the security of devices, password validation is required when configuring via unused phone. Default password is 123456.
-
Tap “Read” button to check current status and sensor data of device.
-
Tap “Write” button to write all your settings to the device.
Note:
- Ensure the location of smartphone NFC area and it’s recommended to take off phone case.
- If the smartphone fails to read/write configurations via NFC, keep the phone away and back to try again.
- EM300 series can also be configured by dedicated NFC reader provided by Milesight IoT or you can configure it via TTL interface inside the device.
LoRaWAN Settings
LoRaWAN settings is used for configuring the transmission parameters in LoRaWAN® network.
Basic LoRaWAN Settings:
Go to Device->Setting->LoRaWAN Settings of ToolBox App to configure join type,
App EUI, App Key and other information. You can also keep all settings by
default.
Parameters
|
Description
---|---
Device EUI| Unique ID of the device which can also be found on the label.
App EUI| Default App EUI is 24E124C0002A0001.
Application Port| The port used for sending and receiving data, default port
is 85.
Join Type| OTAA and ABP mode are available.
LoRaWAN Version| V1.0.2, V1.0.3, V1.1 are available.
Application Key| Appkey for OTAA mode, default is
5572404C696E6B4C6F52613230313823.
Device Address| DevAddr for ABP mode, default is the 5th to 12th digits of SN.
Network Session Key| Nwkskey for ABP mode, default is
5572404C696E6B4C6F52613230313823.
Application
Session Key
| Appskey for ABP mode, default is 5572404C696E6B4C6F52613230313823.
Spread Factor| If ADR is disabled, the device will send data via this spread
factor.
Confirmed Mode| If the device does not receive ACK packet from network server,
it will resend data 3 times at most.
Rejoin Mode| Reporting interval ≤ 30 mins: device will send specific mounts of
LoRaMAC packets to check connection status every 30 mins; If no reply after
specific packets, the device will re-join.
Reporting interval > 30 mins: device will send specific mounts of LoRaMAC
packets every to check connection status every reporting interval; If no reply after specific packets, the device will re-join.
ADR Mode| Allow network server to adjust datarate of the device.
Tx Power| Transmit power of device.
Note:
- Please contact sales for device EUI list if there are many units.
- Please contact sales if you need random App keys before purchase.
- Select OTAA mode if you use Milesight IoT cloud to manage devices.
- Only OTAA mode supports rejoin mode.
LoRaWAN Frequency Settings:
Go to Setting- >LoRaWAN Settings of ToolBox App to select supported
frequency and select channels to send uplinks. Make sure the channels match
the LoRaWAN® gateway.
If frequency is one of CN470/AU915/US915, you can enter the index of the
channel that you want to enable in the input box, making them separated by
commas.
Examples:
1, 40: Enabling Channel 1 and Channel 40
1-40: Enabling Channel 1 to Channel 40
1-40, 60: Enabling Channel 1 to Channel 40 and Channel 60
All: Enabling all channels
Null: Indicates that all channels are disabled
Note:
For -868M model, default frequency is EU868;
For -915M model, default frequency is AU915.
Basic Settings
Go to “Device->Setting->General Settings” of ToolBox App to change the reporting interval, etc.
Parameters
|
Description
---|---
Reporting Interval| Reporting interval of transmitting data to network
server.Default: 600s
Temperature Unit| Change the temperature unit displayed on the ToolBox.
Note:
- The temperature unit in the reporting package is fixed as °C.
- Please modify the threshold settings if the unit is changed.
Change Password| Change the password for ToolBox App or software to read/write this device.
Advanced Settings
Calibration Settings
ToolBox supports numerical calibration for all items. Go to
Device->Setting->Calibration Settings of ToolBox App to type the calibration
value and save, the device will add the calibration value to raw value.
Threshold Settings
EM300 series will upload the current data once instantly after the threshold
is triggered.
Go to Device->Setting->Threshold Settings of ToolBox App to enable the
threshold settings and input the threshold.
Maintenance
Upgrade
- Download firmware from Milesight website to your smartphone.
- Open Toolbox App and click “Browse” to import firmware and upgrade the device.
Note:
- Operation on ToolBox is not supported during an upgrade.
- Only Android version ToolBox supports the upgrade feature.
Backup
EM300 devices support configuration backup for easy and quick device
configuration in bulk. Backup is allowed only for devices with the same model
and LoRa frequency band.
- Go to “Template” page on the App and save current settings as a template. You can also edit the template file.
- Select one template file which saved in the smartphone and click “Write”, then attach to another device to write configuration.
Note: Slide the template item left to edit or delete the template. Click the template to edit the configurations.
Reset to Factory Default
Please select one of following methods to reset device:
Via Hardware: Hold on power button (internal) for more than 10s.
Via ToolBox App: Go to “Device->Maintenance” to click “Reset”, then
attach smart phone with NFC area to device to complete reset.
Installation
-
Attach EM300 to the wall and mark the two holes on the wall. The connecting line of two holes must be a horizontal line.
-
Drill the holes according to the marks and screw the wall plugs into the wall.
-
Mount the EM300 to the wall via mounting screws.
-
Cover the mounting screws with screw caps.
-
For leak detection senor, install the probe/cable to the place where liquid may leak. For magn et switch sensor, install the magnet beside the door/window.
Note: For SLD sensor, please ensure the metal pins of the probe are flat on the floor; for ZLD sensor, the cable can’t be twined or accumulated together. The probe or cable of water leakage sensor should be placed in an area of concern where water from a leak would likely accumulate.
Milesight IoT Cloud Management
EM300 series can be managed by Milesight IoT Cloud platform. Milesight IoT cloud is a comprehensive platform that provides multiple services including device remote management and data visualization with the easiest operation procedures. Please register a Milesight IoT Cloud account before operating following steps.
Add a Milesight Gateway
Step 1: Enable gateway embedded network server and “Milesight IoT Cloud”
mode in gateway web GUI.
Note: Ensure gateway has accessed the Internet.
Step 2: Go to “My Devices” page and click “+New Devices” to add gateway to Milesight IoT Cloud via SN. Gateway will be added under “Gateways” menu.
Step 3: Check if gateway is online in Milesight IoT Cloud.
Add EM300 to Milesight IoT Cloud
Step 1: Go to “My Devices” page and click “+New Devices”. Fill in the SN of device and select associated gateway.
Step 2: After the device is online in Milesight IoT Cloud, you can check the data via webpage or mobile App and create dashboard for it.
Device Payload
All data are based on following format(HEX):
Channel1
| Type1| Data1| Channel2| Type2| Data2| Channel 3|
…
---|---|---|---|---|---|---|---
1 Byte
| 1 Byte| N Bytes| 1 Byte| 1 Byte| M Bytes| 1 Byte|
…
For decoder examples please find files on https://github.com/Milesight- IoT/SensorDecoders.
Basic Information
EM300 series sensors report basic information of sensor everytime joining the network.
Channel
| Type| Data Example|
Description
---|---|---|---
ff
|
01(Protocol Version)
| 01| V1
08(Device SN)| 61 27 a2 17 41 32|
Device SN is 6127a2174132
09 (Hardware Version)
| 01 40| V1.4
0a(Software Version)| 01 14|
V1.14
0f(Device Type)
| 00|
Class A
Example:
ff 09 01 00 ff 0a 01 02 ff 0f 00
Channel| Type| Value| Channel| Type|
Value
ff
| 09 (Hardware version)| 0100 (V1.0)| ff| 0a (Software version)| 0102 (V1.2)
Channel| Type| Value| | |
ff
| 0f (Device Type)| 00 (Class A)| | |
Sensor Data
EM300 series sensors report sensor data according to reporting interval (10min by default). Battery level is reported every 6 hours.
Channel
| Type| Description
---|---|---
01| 75(Battery Level)|
UINT8, Unit: %
03
| 67 (Temperature)| INT16, Unit: °C
04| 68(Humidity)|
INT8, Unit: %
05
| 00(Water Leakage Status)| 00=>Not water leakage 01=>Water leakage
06| 00(Magnet Status)|
00=>Magnet switch closed 01=>Magnet switch open
Example: ****
01 75 64 03 67 10 01 04 68 71 05 00 01
Channel| Type| Value| Channel| Type|
Value
01
| 75 (Battery)| 64 => 100%| 03| 67 (Temperat ure)| 10 01 => 01 10 = 272
Temp=272*0.1=27.2°C
Channel| Type| Value| Channel| Type|
Value
04
| 68 (Humidity)| 71=>113
Hum=113* 0.5=56.5%| 05| 00|
01=>Water leakage
Downlink Commands
EM300 series sensors support downlink commands to configure the device. Application port is 85 by default.
Channel
| Type| Data Example|
Description
---|---|---|---
ff| 03 (Set Reporting Interval)| b0 04|
b0 04 => 04 b0 = 1200s