beurer FT 15 Instant Thermometer User Guide

June 6, 2024
Beurer

beurer FT 15 Instant Thermometer User Guide

Signs and symbols

The following symbols are used in these instructions for use, on the packaging and on the type plate for the device and accessories:

| Caution| | Follow instructions for use
---|---|---|---
Storage/Transport

| Permissible storage and transport temperature and humidity| | Type BF applied part
****| Permissible operating temperature and humidity| | Disposal in accordance with EC Directive – WEEE (Was- te Electrical and Electronic Equipment).
| Dispose of packaging in an environmentally friendly manner| |
| Manufacturer| | Batch designation
| Protected against ingress of solid foreign objects greater than

12.5 mm in diameter. Protected against drops of water falling at up to 15° from vertical.

| The CE labelling certifies that the product complies with the es- sential requirements of Directive 93/42/EEC on medical products.

Included in delivery

  • Thermometer
  • These instructions for use
  • 1 x 1,5V LR 41 battery

Important safety information – retain for later use.

In order to make optimum use of all the merits of the clinical thermometer, you should carefully read the operating instructions before using it, retain the instructions for later use and also keep them accessible for other users.

  • The thermometer is intended to measure the temperature of the human body.
  • The FT 15/1 thermometer is only designed for the measuring area on the human body stated in the instructions for
  • Children should not use the thermometer without
  • Before each use, check the thermometer for signs of damage or wear. Damaged or worn thermometers should not be
  • Always wait for the acoustic signal which indicates the minimum time required for Discuss the temperature with your family physician.
  • The thermometer contains sensitive electronic Therefore, protect it from blows, bending, high temperature or direct exposure to sunlight.
  • This thermometer has a flexible measuring tip to provide greater comfort and safety during measurement, particularly in infants and persons who are asleep or have a reduced level of consciousness. The tip must not be bent more than 90°!
  • Using the thermometer in strong electromagnetic fields such as next to a mobile phone, can cause a mailfunctions.
  • When the thermometer is switched on, it carries out a self-test. Therefore the accuracy of measurement need not be tested at regular
  • If the temperature is very abnormal, please contact your family doctor
  • If the Temperture is very abnormal, please contact your family doctor promptly.
  • This device meets the requirments of the EU Directive 93/42/EEC concerning medical devices, as well as those of the Medizinproduktegesetz (German  Medical Devices Act), the European Standard EN 12470-3: Clinical thermometers – part 3: Performance of compact electrical thermometers (non-predictive and predictive) with maximum device and the European Standard EN 60601-1-2 (in accordance with CISPR 11, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-8), and is subject to particular precautions with regard to electromagnetic compatibility. Please note that portable and mobile HF communication systems may interfere with this unit.

Notes on electromagnetic compatibility

  • The device is suitable for use in all environments listed in these instructions for use, including domestic
  • The use of the device may be limited in the presence of electromagnetic disturbanc- This could result in issues such as error messages or the failure of the display/ device.
  • Avoid using this device directly next to other devices or stacked on top of other devices, as this could lead to faulty If, however, it is necessary to use the device in the manner stated, this device as well as the other devices must be monitored to ensure they are working properly.
  • The use of accessories other than those specified or provided by the manufacturer of this device can lead to an increase in electromagnetic emissions or a decrease in the device’s electromagnetic immunity; this can result in faulty operation.
  • Failure to comply with the above can impair the performance of the device.

Measuring methods

Temperature measurement in the anus (rectal)
This method of measurement is most reliable and most accurate. Guide the tip of the thermometer carefully 2 to 3 cm into the anus. The measurement time with this thermometer at this site is only about 10 seconds. The end of the measuring time is indicated by an signal tone.

Measurement in the mouth cavity (oral)

For this purpose, guide the tip of the thermometer carefully into one of the heat pouch- es beneath the tongue, to the left or the right of the root of the tongue.

Measurement of temperature in the armpit (axillary)

This method of measurement is relatively inaccurate. Therefore, it cannot be recom- mended from a medical point of view.

Mode of measurement|

Recommended time required for measurement

| Mean divergence to the rectal method
---|---|---
in the anus| until the acoustic signal|
in the oral cavity| until the acoustic signal| -0.4 °C to -1.5 °C
(-0.7 °F to -2.7 °F )
in the armpit| until the acoustic signal| -0.7 °C to -2.0 °C
(
-1.26 °F to -3.6 °F)

Use

Press the On/Off switch to turn the unit on. A short acoustic signal will announce that it is switched on. The thermometer will carry out a display will be visible**. Then “Lo °C (Lo °F)” or the value of the last measurement will appear in the display. Then the reference value of 37 °C (98.6 °F) will appear. Then the flashing symbol “°C” appears and the symbol “Lo” is shown in the display screen. The thermometer is now ready for use. During the measurement, the current tempera-ture is displayed continuously, and the “°C” (“°F”) symbol flashes on and off. The measurement is completed when a stable temperature has been reached. An acoustic signal (10 long beeps) sounds, the “°C” (“°F”) symbol stops flashing and the measured temperature is displayed. So long as the temperature is less than 32 °C (89.6 °F), the “°C” (“°F”) symbol continues to flash and “Lo °C (Lo °F)” is shown on the display. Higher values are displayed directly, e.g. 32.1 °C (89.9 °F). If temperatures over 37.8 °C (100 °F) are measured, a fever alarm (30 short beeps in 10 seconds) sounds. If temperatures over 43.0 °C (109.4 °F) are measured, the symbol for “Hi °C (Hi °F)” appears. The measurement time is very quick compared to conventional thermometers and is only 10 seconds for the rectal measurement. More accurate measurements are possible by extending the measurement time beyond the acoustic signal. For measurements in the armpits the recommended measurement time should be maintained in spite of the acoustic signal. To prolong the life of the battery, please switch off the thermometer by briefly pressing the On/Off key after the measurement. Otherwise the thermometer will automatically switch off after 10 minutes.

Memory

The last measured value will be stored automatically. This value is displayed when the On/Off button is pressed. The memory symbol is also shown beside the measured value, e.g. 37.5 °CM (99.5 °FM).

Changing the measuring unit

The temperature can be displayed in degrees Celsius (°C) and degrees Fahrenheit (°F). To set the measuring unit press and hold the On/Off button for longer than 2 seconds when switching on until the measuring unit changes. The saved value is displayed in the new measuring unit.

Changing the battery

The clinical thermometer contains a long-life alkali-manganese battery (LR 41, 1.5 V), which will last for approx. 2 years. The battery has to be replaced when “T” appears in the bottom right corner of the display. Press down the battery cover at the end of the device with your fingers and then pull it firmly back. Remove the old battery and replace it with a battery of the same type. The + sign on the battery must point upwards. Then put the battery cover back onto the case.

The empty, completely flat batteries must be disposed of through specially designated collection boxes, recycling points or electronics retailers. You are legally required to dispose of the batteries.
The codes below are printed on batteries containing harmful substances:
Pb = Battery contains lead
Cd = Battery contains cadmium,
Hg = Battery contains mercury

  • **** If your skin or eyes come into contact with battery fluid, flush out the affected areas with water and seek medical
  • Choking hazard! Small children may swallow and choke on batteries. Store the batteries out of the reach of small children.
  • Observe the plus (+) and minus (-) polarity
  • If a battery has leaked, put on protective gloves and clean the battery compartment with a dry
  • Protect the batteries from excessive heat.
  • Risk of explosion! Never throw batteries into a fire.
  • Do not charge or short-circuit
  • If the device is not to be used for a long period, take the batteries out of the battery
  • Use identical or equivalent battery types
  • Always replace all batteries at the same time.
  • Do not use rechargeable
  • Do not disassemble, split or crush the

Cleaning/Disinfection

The device must be cleaned and disinfected before and after each use. The thermome- ter is 100% water-proof. For the purpose of cleaning or disinfection, it can be dipped into water or disinfectant without any difficulties
Under no circumstances should the thermometer be boiled! Use one of the following disinfectants in accordance with the manufacturer’s instructions. Other cleaning agents or methods could impair the function of the thermometer or damage it.
Name of the agent: Isopropanol 70% Pharmacy; Gigasept FF; Lysoformin; Aseptisol.

Storage/Disposal

When you are not using the thermometer, please retain it in the original protective cover.
The accuracy of this thermometer has been carefully checked and developed with regard to a long useful life.
If using the device for commercial medical purposes, it must be regularly tested for accuracy by appropriate means. Precise instructions for checking accuracy may be requested from the service address.
For environmental reasons, do not dispose of the device in the household waste at the end of its useful life. Dispose of the unit at a suitable local collection or recycling point. Dispose of the device in accordance with EC Directive – WEEE (Waste Electrical and Electronic Equipment). If you have any questions, please contact the local authorities responsible for waste disposal.

Technical data

Type:

|

FT 15/1

---|---
Range of measurement:| 32 °C (89.6 °F) to 42.9 °C (109.2 °F)
Accuracy of of measurement:| ±0.1 °C in a water bath with a temperature of 35.5 °C (95.9 °F) to 42.0 °C (107.6 °F)

±0.2 °C in a water bath with a temperature of 32.0 °C (89.6 °F) to 35.4 °C (95.7 °F)

±0.2 °C in a water bath with a temperature of 42.1 °C

(107.8 °F) to 42.9 °C (109.2 °F)

Ambient temperature:| 10 °C (50 °F) to 40 °C (104 °F), with 30% to 85% relative humidity
Storage temperature:| -10 °C (14 °F) to +60 °C (140 °F), with 25% to 90% relative humidity

**Warranty /service**

The warranty conditions below shall not affect the seller’s statutory warranty obligations which ensue from the sales agreement with the buyer.
The warranty shall apply without prejudice to any mandatory statutory provisions on liability.
The worldwide warranty period is 5 years, commencing from the purchase of the new, unused product from the seller.
The warranty only applies to products purchased by the buyer as a consumer and used exclusively for personal purposes in the context of domestic use.
German law shall apply.
During the warranty period, should this product prove to be incomplete or defective in functionality in accordance with the following provisions, Beurer shall carry out a repair or a replacement delivery free of charge, in accordance with these warranty conditions.
If the buyer wishes to make a warranty claim, they should approach their local retailer in the first instance: see the attached “International Service” list of service addresses.
The buyer will then receive further information about the processing of the warranty claim, e.g. where they can send the product and what documentation is required.
A warranty claim shall only be considered if the buyer can provide Beurer, or an author- ised Beurer partner, with

  • a copy of the invoice/purchase receipt, and
  • the original product

The following are explicitly excluded from this warranty:

  • deterioration due to normal use or consumption of the product;
  • accessories supplied with this product which are worn out or used up through proper use (e.g. batteries, rechargeable batteries, cuffs, seals, electrodes, light sources, attachments and nebuliser accessories)
  • products that are used, cleaned, stored or maintained improperly and/or contrary to the provisions of the instructions for use, as well as products that have been opened, repaired or modified by the buyer or by a service centre not authorised by Beurer; service centre and customer;
  • products purchased as seconds or as used goods;
  • consequential damage arising from a fault in this product (however, in this case, claims may exist arising from product liability or other compulsory statutory liability provisions).

Repairs or an exchange in full do not extend the warranty period under any circum- stances.

Subject to errors and changes

BEURER GmbH
Söflinger Str. 218 • 89077 Ulm (Germany)
www.beurer.de
www.beurer-healthguide.com

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Beurer User Manuals

Related Manuals