LaMotte PRO250-NJ Pool MGR. PRO 250 Test Kit User Guide

June 6, 2024
lamotte

LaMotte PRO250-NJ Pool MGR. PRO-- logo. PRO250-NJ R
Code 7001-NJ-01
Read User’s Guide Before Testing

Free Chlorine

LaMotte PRO250-NJ Pool MGR. PRO -- PRO 250 Test Kit

  1. Slide Chlorine Octa-Slide 2 Bar (3401-01) into top of Viewer.
  2. Fill tube to 5 mL line with sample.
  3. Add 5 drops of DPD 1A (P-6740) and 5 drops of *DPD 1B (P-6741). Cap and invert to mix.
  4. Insert tube into top of Octa-Slide 2 Viewer (1101).
  5. Read test result from Octa-Slide 2 Bar in ppm Free Chlorine. Retain sample if Total Chlorine is to be tested.

pH

LaMotte PRO250-NJ Pool MGR. PRO -- PRO 250 Test Kit

  1. Slide pH Octa-Slide 2 Bar (3403-01) into top of Viewer.
  2. Fill tube to 5 mL line with sample.
  3. Add 5 drops of pH Indicator (P-7026). Cap tube and invert to mix.
  4. Insert tube into top of Octa- Slide 2 Viewer (1101).
  5. Read test result from Octa- Slide 2 Bar in pH units. If pH is not in desired range, retain sample for Acid/Base Demand.

Alkalinity

LaMotte PRO250-NJ Pool MGR. PRO -- PRO 250

  1. Fill tube to upper line with sample.
  2. Add 5 drops of *Alk 1 (P-7028). Swirl to mix.
  3. Add *Alk Titrant (P-6111) dropwise while swirling until color changes from blue-green to RED. Record total drops.
  4. Each drop equals 10 ppm Total Alkalinity.
    NOTE : If tube is filled to lower line, each drop equals 20 ppm Alkalinity

Ca Hardness

LaMotte PRO250-NJ Pool MGR. PRO -- PRO 250

  1. Fill tube to lower line with sample.

  2. Add 5 drops of Hard 1 (P-4259 and 5 drops of
    Hard 2 (P-7030).
    Swirl to mix.

  3. Add Ca Hard Titrant (P-7031) dropwise while swirling until color changes from red to BLUE.
    Record total drops.

  4. Each drop equals 20 ppm Ca Hardness.
    NOTE: If tube is filled to upper line, each drop equals 10 ppm Ca Hardness.

Cyanuric Acid

LaMotte PRO250-NJ Pool MGR. PRO -- PRO 25

  1. Fill small round tube (1161) to top line with sample.
  2. Add one *Cyanuric Acid tablet (6994A). Cap and shake to dissolve.
  3. Replace solid cap with calibrated square tube and cap collar (no brush). The square tube will fill with turbid liquid.
  4. Viewing from above, adjust the square tube until the black dot just barely disappears. Read
  5. result atwater level within the square tube.

NOTE: For samples greater than 100 ppm, retest by adding sample to lower line, add tap water to top line.Follow steps 2-4. Multiply result by 2.

Total Chlorine

LaMotte PRO250-NJ Pool MGR. PRO -- Total Chlorine

  1. Remove cap from Free Chlorine sample and add 5 drops of DPD 3 (P-6743).
  2. Cap tube and invert to mix.
  3. Insert tube into top of viewer. Read test result from Octa-Slide 2 Bar in ppm Total Chlorine.
    NOTE : Total Chlorine minus Free Chlorine equals Combined Chlorine.
    *Potential health hazard. Read SDS at www.lamotte.com Emergency information for all LaMotte reagents is available from Chem-Tel (US, 1-800-255-3924) (International,  call collect, 813-248-0585).

Acid/Base Demand

LaMotte PRO250-NJ Pool MGR. PRO -- pH tube in viewer

  1. Remove cap from pH tube in viewer. Leave pH Octa-Slide 2 Bar (3403-01) in Viewer.
  2. If pH is High: add *Acid (P-6068) one drop at a time and mix, until desired color match occurs. Record number of drops.
  3. See Table at right for recommended dosage.
  4. If pH is Low: add Base (P-6460) one drop at a time and mix, until desired color match occurs. Record number of drops.
  5. See Table at right for recommended dosage.
    NOTE: For accurate results in pools with low pH and high alkalinity readings, the alkalinity level must be adjusted to the proper range before performing Base Demand test.

Acid Demand Table for Lowering pH / Muriatic Acid   Required for Adjustment
Drops of Acid Solution Used


Gallons| 1| 2| 3| 4| 5| 6| 7| 8| 9| 10
500| 1.1| 2.2| 3.3| 4.4| 5.5| 6.6| 7.7| 8.8| 9.9| 11.0
1000| 2.2| 4.4| 6.6| 8.8| 11.0| 13.1| 15.3| 1.1| 1.2| 1.4
5000| 11.0| 1.4| 2.1| 2.7| 3.4| 4.1| 4.8| 5.5| 6.2| 6.9
10,000| 1.4| 2.7| 4.1| 5.5| 6.5| 8.2| 9.6| 11.0| 12.3| 13.7
20,000| 2.7| 5.5| 8.2| 11.0| 13.7| 16.4| 19.2| 21.9| 24.6| 27.4
50,000| 6.9| 13.7| 20.5| 27.4| 34.2| 41.4| 47.9| 54.8| 61.6| 68.5

Fluid Ounces Pints

Base Demand Table for Raising pH / Soda Ash Required for Adjustment
Drops of Base Solution Used

Gallons| 1| 2| 3| 4| 5| 6| 7| 8| 9| 10
500| 0.3| 0.6| 0.9| 1.2| 1.5| 1.8| 2.1| 2.4| 2.7| 3.0
1000| 0.6| 1.2| 1.8| 2.4| 3.0| 3.5| 4.1| 4.7| 5.3| 5.9
5000| 3.0| 5.9| 8.9| 11.8| 14.7| 1.1| 1.3| 1.5| 1.7| 1.8
10,000| 5.9| 11.8| 1.1| 1.5| 1.8| 2.2| 2.6| 3.0| 3.3| 3.7
20,000| 11.8| 1.5| 2.2| 3.0| 3.7| 4.4| 5.2| 5.9| 6.6| 7.4
50,000| 1.8| 3.7| 5.5| 7.4| 9.2| 11.1| 12.9| 14.7| 16.6| 18.4

Ounces (oz.) Pounds ( bs.)

LaMOTTE COMPANY
Helping People Solve
Analytical Challenges
802 Washington Ave
Chestertown • Maryland • 21620 • USA
800-344-3100 USA
410-778-3100 (Outside U.S.A.)
Fax 410-778-6394
Visit us on the web at www.lamotte.com