MIBOXER Constant Voltage DMX512 & RDM Decoder User Manual
- June 6, 2024
- MiBOXER
Table of Contents
Subordinate New Brand
Constant Voltage DMX512 & RDM Decoder
Model No.: D1-CX / D2-CX / D3-CX / D4-CX / D5-CX
Features
- Accord with DMX512 standard protocol.
- Digital Display, Set DMX initial address through a button.
- Support RDM function.
- 2000hz/500hz Output PWM frequency is optional.
- Logarithm/Linear dimming curve is optional.
- Anti-reverse protection function
- Short circuit&Overcurrent protection and recovery function.
- self-testing protection function when power on.
Parameter
Model No. | D1-CX | D2-CX | D3-CX | D4-CX | D5-CX |
---|---|---|---|---|---|
Output | 20A/Channel | 10A/Channel | 6A/Channel | 5A/Channel | 4A/Channel |
Total Output | Max 20A | Max 18A | Max 20A | ||
Input Voltage | Common anode | ||||
Input Signal | -20~60°C | ||||
Connection | -20~60°C | ||||
Working Temp. | DC12~24V |
Function Settings
1. Digital Display status description
Self-locking: Get into locking state when there is no operation over 30
seconds, digital display with low light or OFF.
Unlock Long press M button 2 seconds to make a digital display with high
light, quit self-locking state.
The address is always ON: DMX signal valid.
Address flickering: DMX signal invalid.
Err: Short circuit/overcurrent protection; self-recover after 10 seconds.
2. DMX initial address setting
Under unlock status, when digital display shows 001-512( for example ), Short
press ▲ button or ▼ button, you can change the DMX initial address; Long
press, you can change it quickly.
For Example Set the Initial address to 100
D1-CX | D2-CX | D3-CX | D4-CX | D5-CX |
---|
Occupy 1 address
100| Occupy 2 address
100-101| Occupy 3 address
100-102| Occupy 4 address
100-103| Occupy 5 address
100-104
3. System Parameter Setting Instruction
Under unlock status: Long press M button 3 seconds to make the digital display
show or , then get into system parameter setting. By this time, short press M
button to switch 4 different parameter setting circularly.
Parameter 1: PWM frequency setting(show or ; Short press ▲ button or ▼
button to switch.
Set to PWM high-frequency output, 2000Hz. (Factory default parameter)
Set to PWM low-frequency output,500Hz.
Parameter 2: Dimming Curve setting(Show or ), short press ▲ button or ▼
button to switch.
Dimming curve is logarithm dimming. (Factory default parameter)
** Dimming curve is linear dimming.
Parameter 3: Dimming smoothness setting(show or ), short press ▲ button or
▼ button to switch.
** Smooth dimming. (Factory default setting)
Standard dimming.
Parameter 4: Digital display showing setting(show or ) short press ▲ button
or ▼ button to switch.
Under self-locking status, the digital display is always ON (low lighting
showing). (Factory default parameter)
Under self-locking status, digital display OFF.
Exit system mode: long press M button 1 second to exit. Or it will be self
exit if there is no operation over 8 seconds.
4. Restore factory default.
Under unlock status, long press M button 10 seconds until digital display
shows .
Dimming curve diagram
Connection diagram
Attention:
- If the decoder is over 32pcs or using the super long signal cable, you need a DMX signal amplifier. Amplify signal cannot be over 5 times.
- If there is an overshoot effect due to the long signal cable or low-quality circuit, please connect 0.25W 90-120Ω terminal resistance at the end of each DMX signal cable.
Attention
- This product should be debugged and installed by professionals.
- Please check whether the output voltage of the power supply meets the requirements of the product voltage range.
- The product is not waterproof, please install it in the waterproof box when installed outdoors.
- Before switching on the power, please ensure that all wiring is correct, so as not to cause damage to the devices。
- If a fault has occurred, non-professionals do not repair it without permission, otherwise, the devices will be damaged.
Made in China
Documents / Resources
|
MIBOXER Constant Voltage DMX512 & RDM
Decoder
[pdf] User Manual
D1-CX, D2-CX, D3-CX, D4-CX, D5-CX, Constant Voltage DMX512 RDM Decoder
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>