Introduction

A programmable timers EP110, EP210, EP310 are used to switch ON/OFF the heating system, the hot water or any electronical device like pumps or lights as needed. It works by controlling with programmed schedules (24H or 5-2 schedule types) which contain 3 time programs each

Product Compliance

EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.

Safety Information

Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry. This product must be installed by a competent person and in accordance with all the EU and national regulations.

Technical data

  EP110 EP210 EP310
Power Supply 230 V AC 230 V AC 230 V AC
Max load 3 (1) A 3 (1) A 3 (1) A
Output NO / COM / NC

volt free

| 2 x SPDT 230V AC| 3 x SPDT 230V AC
Number of channels| 1| 2| 3
Dimensions [mm]| 120 x 98 x 27| 120 x 98 x 27| 120 x 98 x 27

Buttons functions

Button Function
  Select operating mode (ON, ONCE, AUTO, ADV, OFF)
  Activate/deactivate BOOST function
  Turn on the LCD backlight

Press for 3 sec to activate HOLIDAY mode
 | Increases the selected setting
 | Decreases the selected setting
 | Select a clock or programme setting
 | Sets a clock or programme setting
 | Reset to Factory settings

LCD display icon description

EP110LCD display 1

  1. Device operation (animated icon)
  2. Number of hours for the BOOST function
  3. ON/OFF indicator
  4. Work mode
  5. AM/PM
  6. Holiday mode
  7. Clock
  8. The day of the week
  9. Program number

EP210LCD display 2

1. Zone I operation mode
2. Day of the week
3. Program number
4. ON/OFF indicator
5. Zone II operation mode
6. Zone II work status
7. AM/PM
8. Number of hours for the BOOST function for Zone II
9. Number of hours for the BOOST function for Zone I
10. Zone I work status
11. Clock
12. Holiday mode

EP310LCD display 3

1. Zone I operation mode
2. Zone II operation mode
3. Zone III operation mode
4. Program number
5. ON/OFF indicator
6. Holiday mode
7. AM/PM
8. Number of hours for the BOOST function for Zone III
9. Zone III work status
10. Zone I work status
11. Number of hours for the BOOST function for Zone II
12. Zone II work status
13. Number of hours for the BOOST function for Zone I
14. Clock
15. Day of the week

Jumpers settings

The parameters can be changed using the jumpers on the back of the device.

Note : Disconnect power supply before working with the device.LCD
display 4

Note : After changing the settings, it is necessary to reset the device using button.

Wiring diagram

All wire connectors are located on the back of the device. To remove the cover, loose two screws located at the bottom of the device and then remove the back of the housing.
Note : Disconnect power supply before working with the device.wiring
diagram 1wiring diagram 2wiring diagram
3

Setting time and date

setting time 1setting time
2 setting time 3

Operation modes

There are 5 different work modes available. Using MODE button, you can change modes directly according to the following sequence.operation mode
1

ON modeoperation mode 2

ONCE modeoperation mode 3

AUTO modeoperation mode 4

ADV mode

The ADV mode can be activated if the ONCE or AUTO mode is selected when it is activated.operation mode 5

To turn the ADV mode on or off, press the MODE button for 3 seconds. The mode of operation of the mode has been presented in the chart below.

OFF modeoperation mode 6

Programming EP110 controller

You can create 3 independent time schedules. There are 2 work models to choose from:
• business days + weekend (5-2)
• each day separately (24 hours)
Controller works by default in working days + weekend mode (5-2).

To set each day separately (24 hours), change the jumper position according to the diagram on previous page.programming 1programming
2

Programming EP210/EP310 controller

You can create 3 independent time schedules for each zone. There are 2 work models to choose from:
• business days + weekend (5-2)
• each day separately (24 hours)
Controller works by default in working days + weekend mode (5-2).

To set each day separately (24 hours), change the jumper position according to the diagram on previous page.programming 3 programming
4

HOLIDAY mode

Holiday mode is used to disable all controller outputs for a specified number of days (up to 31 days). When HOLIDAYS mode is active, aircraft icon will appear on the display.programming 5

BOOST Function

BOOST function extends the active program time to 1-9 hours. Press +Hr button to activate BOOST mode (each press of the button extends the active program by 1 hour).operation mode 6

Factory Settings

you made a mistake, want to change controller parameters or return to its factory settings, you can reset controller with reset button.
Note : RESET button will permanently delete your existing settings.programming 7