Congratulations on purchasing a new AirWerx 90 Dehumidifier. Your new dehumidifier comes with an extensive warranty plan. To register, simply fill in and return the warranty card provided in your dehumidifier box.

Be sure to note your dehumidifier serial number as you will need it for registration.

Safety Notes

  • The AirWerx Series Dehumidifier must always be connected using a grounded electrical connection (as required for all electrical appliances). If non-grounded wiring is used, all liability reverts to the owner and the warranty is voided.
  • AirWerx Dehumidifiers should only be maintained and repaired by a qualified technician.
  • AirWerx Dehumidifiers are only intended for operation when oriented with the unit sitting on its feet and level. Operating the unit in any other orientation could allow water to flood electrical components.
  • Always unplug dehumidifier before moving.
  • If there is a chance that water flooded the dehumidifier, it should be opened and allowed to dry thoroughly before reconnecting to electrical power and restarting.
  • To ensure proper operation, neither the inlet nor discharge should be positioned against a wall. The inlet requires a minimum of 12″ clearance and the discharge requires a minimum of 36″ clearance.
  • The best option for proper diffusion of air throughout the room is to have the discharge blowing away from a wall and the inlet pulling air in parallel to a wall.
  • Do not insert your fingers or any object into the inlet or discharge.
  • All work on the dehumidifier should be done with the unit “off” and unplugged.
  • Do not use water to clean the exterior. To clean unit, unplug from power, then use a damp cloth to wipe the exterior.
  • Do not stand on the machine or use it as a device to hang clothes.

Identification

For future reference, write down the model, serial number, and date of purchase for your dehumidifier. This is extremely helpful if you need to seek assistance in the future. The data label on the side of your unit has the key characteristics of your specific unit.

Model number: AirWerx 90
Serial Number: __    Date of Purchase: _____

For additional questions concerning your dehumidifier, the following options are available:
• Contact your installing contractor
• E-mail: [email protected]

Electrical Supply

Power Supply: 115 V, 60 Hz AC, Single Phase
Outlet Requirement: 3-Prong, GFI
Circuit Protector: 15 Amp

WARNING : 240 Volts AC may cause serious injury from electric shock.
To reduce the risk of injury:

1. Disconnect electrical power before servicing.
2. Only plug unit into grounded electrical circuit.
3. Do not use an extension cord.
4. Do not use a plug adapter.

Principle of Operation

The AirWerx Series Dehumidifier utilizes its integral humidistat to monitor the conditioned space. When the relative humidity goes above the selected set point, the dehumidifier will energize. Air is drawn across an evaporator coil, which is cooler than the dew point of air. This means moisture will condense out of the air. The air is then reheated through the condenser coil and distributed back into the room.

Installation

The area to be controlled should be sealed with a vapor barrier. If the unit is installed in a crawlspace, all vents should be sealed.

WARNING : Do not install your dehumidifier in a corrosive environment. Some liquid vapor barriers dry via “solvent evaporation”. Always make sure that barrier is completely dry and area is thoroughly ventilated before installing dehumidifier.

Step #1: Place dehumidifier on a level surface.

If the unit is handled in such a manner that the compressor did not remain in the upright position, you will need to place it on a level surface and wait a minimum of 2 hours before turning the unit “on”.

NOTE : Do not place directly on vapor barrier. Elevation is required to allow the condensate water to drain via gravity.

Step #2: Set Up Drain Line

The drain line should be routed to a suitable drain on the outside. It must flow down to the drain without any loops, dips, or valleys.

Recommended Drain Option-Transition to PVC Pipe

  1. Cut a piece of 3/4″ OD PVC that is approx. 6″ long.
  2. Insert PVC into a 3/4″ elbow, then attach to a 3/4″ OD length of PVC to drain. (Note: Keep the length of PVC drain pipe to a minimum).
  3. Insert the open end of the tubing into the 3/4″ pipe so that ii does not extend into the elbow fitting. For proper flow, a minimum downward slope of 1″ per 1 O’ run is required. ( Note: If a proper downward angle is not possible, then it is recommended to use an AirWerx 90 which includes an integrated pump or utilize an external condensate pump).
  4. Support the PVC tubing so that it maintains a smooth downward flow to drain.
  5. Always test the drain before leaving the installation area.

baseaire AirWerx 90 Dehumidifier - Recommended Drain Option-Transition to
PVC Pipe

Step #3: Plug unit into 15 amp grounded circuit.

Key Functions

baseaire AirWerx 90 Dehumidifier - Key Functions

Indicator Lights

baseaire AirWerx 90 Dehumidifier - Indicator Lights

Remote Control Instructions

AirWerx Dehumidifiers can be controlled using an optional remote accessory. The AirWerx Remote Control connects to your Airwerx Series Dehumidifier via a 25′ CAT 5 cable. The remote control contains an integrated sensor which gives you multiple options for remotely controlling your unit, in addition to monitoring the conditions surrounding the dehumidifier.

One application for the remote control is to install the dehumidifier in one room with the conditioned air ducted into a second room that contains the remote. For example, the dehumidifier could be installed in a laundry room and ducted into a living room. The remote would then be mounted in the living room so the remote sensor can control the humidity and provide easy controls for the user.

Another useful application for the remote control is if the dehumidifier is in area that’s difficult to access on a regular basis. For instance, if your dehumidifier is installed in your crawl space, the remote could be mounted in your living space or garage. This provides you with an easy way to monitor the dehumidifier.

NOTE: Symbols indicated below will only appear when the dehunidifier is powered on.

baseaire AirWerx 90 Dehumidifier - Remote Control
Instructions

Operating Instructions

  1. Start the machine
    Press the power key to turn the machine on.

  2. Adjust Settings
    Use the up and down arrow keys to adjust your desired setpoint ( typically 50-55%) .

  3. Stop the Machine
    Press the power key again and the machine will stop. Note the fan will continue to operate for 1 minute after the unit has turned off.
    NOTE : Do not disconnect the power cord to force the unit to stop. Always use the power button.

  4. Water Drainage
    During normal operation, the AirWerx 90 will automatically drain by the force of gravity. If you want to move or store the machine, wait at least 10 minutes to allow the machine to completely defrost, then lean unit gently towards drain to ensure that it is completely drained.

Airwerx 90 Diagram

baseaire AirWerx 90 Dehumidifier - Airwerx 90 Diagram

Maintenance

baseaire AirWerx 90 Dehumidifier - Maintenance 1 baseaire AirWerx 90 Dehumidifier - Maintenance 2

Dehumidifier Storage

If the unit will be stored for an extended period of time, complete the following steps:

1. Turn off the unit and allow to dry.
2. Wrap and secure the power cord.
3. Cover the filter mesh.
4. Store in a clean, dry space.

Ducted Applications

Ducting the dehumidifier allows the unit to be in one room while conditioning an adjacent room. The inleV return collar ( optional accessory, PN: W-103) is designed for 12″ flex ducting while the supply grille is designed for 6″ flex ducting.

Be sure to secure the ducting with tie wrap. Also, keep in mind, that the supply ducting can be screwed into an adapter if necessary.

Ducting Installation

  • Maximum total length of duct run= 1 O’
  • Maximum length if only ducting inlet or outlet= 6′
  • To connect 12″return ducting. it may be helpful to:
    1. Remove inlet grille from end cap.
    2. Connect duct to inlet grille.
    3. Reconnect inlet grille to end cap.

Note: The supply duct adapter is standard on all units. Return duct is an optional accessory.

Removing Duct Adapter
If it is necessary to remove the adapter, place hand at bottom of the adapter and use your fingers to pull out and down. This will remove the cover hooks from the machine.

Installing Duct Adapter
To install adapter, line duct up with holes on the side of unit push up from the base of the adapter.

baseaire AirWerx 90 Dehumidifier - Installing Duct
Adapter

Flex Duct Installation
Rotate the flex duct counter-clockwise.

Flex Duct Removal
Rotate flex duct clockwise or remove wire tie.

Troubleshooting

baseaire AirWerx 90 Dehumidifier - Troubleshooting

AirWerx 90 Spare Parts

baseaire AirWerx 90 Dehumidifier - AirWerx 90 Spare
Parts

Limited Warranty

This limited warranty starts from the date of purchase. BASEAIRE warrants to the original purchaser that this BASEAIRE product is free from manufacturing defects in material or workmanship for the limited warranty period of:

Six (6) Month parts and labor. This includes the shipments charges for replacement parts or unit.

One (1) year parts and labor. This does not include the shipment charge to send the defective product back to be repaired or replaced.

Three (3) years parts and labor on Refrigeration System ONLY (Compressor, Condenser, and evaporator). Transportation cost, not included

Five (5) years parts on Refrigeration System ONLY(Compressor, Condenser, and evaporator). Transportation cost, not included

This limited warranty is valid only on products purchased from the manufacturer or BASEAIRE authorized dealer and operated, installed, and maintained according to the instructions included in this user guide or furnished with the product. BaseAire will not provide in-home service during or after the warranty period. You may be responsible for the shipping charge to bring the product to the manufacturer for service.

To receive warranty service, the purchaser must contact BASEAIRE at 888-641-8862 or [email protected]. A proof of purchase or order number is required to receive warranty service. During the applicable warranty period, a product will be repaired or replaced at the sole option of BASEAIRE.

Limited Warranty Exclusions

This limited warranty covers manufacturing defects in materials or workmanship encountered in normal household, commercial or noncommercial use of this product and shall not cover the following:

  • Damage occurs in uses for which this product was not intended for.
  • Damage caused by unauthorized modification or alteration of the product.
  • Cosmetic damage including scratches, dents, chips, and other damage to the product’s finishes.
  • Damage caused by abuse, misuse, pest infestation, accident, fire, floods, or other acts of nature.
  • Damage caused by incorrect electrical line current, voltage, fluctuations, and surges.
  • Damage caused by failure to perform proper maintenance of the product.

The use of this product in SPA or a room with OUTDOOR POOL invalidate or voids limited warranty.