Specifications:
Indoor use in dry location
Model: MT10N
Power: 120VAC, 60Hz
Tungsten: 1200W
Resistive: 1800W
Motor: 1/2 HP
Time Delay: 5, 10, 30, 60 mins, 2 or 4 hours
Humidity: 95% RH, non-condensing
Operating Temperature: 32° to 131° F (0° to 55° C
Indoor use in dry location
FCC
This device complies with part 15 of the FCC and Industry Canada license-
exempt RSS standard(s). Operation is subjected to the following two
conditions:
(1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
FCC NOTE : The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
— Reorient or relocate the receiving antenna.
— Increase the separation between the equipment and receiver.
— Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
— Consult the dealer or an experienced radio/TV technician for help.
NOTE: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
Important note: To comply with the FCC RF exposure compliance
requirements, no change to the antenna or the device is permitted. Any change
to the antenna or the device could result in the device exceeding the RF
exposure requirements and void the user’s authority to operate the device
CAUTION – PLEASE READ!
This device (MT10N) is intended for installation in accordance with the
National Electric Code and local regulations in the United States, or the
Canadian Electrical Code and local regulations in Canada. If you are unsure or
uncomfortable about performing this installation consult a qualified
electrician.
WARNING – SHOCK HAZARD
TURN OFF THE POWER to the circuit for the switch and lighting fixture at the
service panel (circuit breaker) prior to installation.
ALL WIRING CONNECTIONS MUST BE MADE WITH THE POWER OFF to avoid personal
injury and/or damage to the switch.
OTHER WARNINGS
Risk of Fire
Risk of Electrical Shock
Risk of Burns
WARRANTY
Our Products warrants this product to be free from manufacturing defects for a
period of one year from the original date of consumer purchase. This warranty
is limited to the repair or replacement of this product only and does not
extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an
implied warranty lasts or permit the exclusion or limitation of incidental or
consequential damage, so the above limitations may not apply to you. This
warranty gives you specific rights, and you may also have other rights which
vary from state to state.
Part 1. Installation CHANGING THE COLOR OF THE
PADDLE(OPTIONAL)
This step is optional. Before you start you may want to change the color of
the paddle to match your wallplate or decor.
1. Push side tabs in on one side and then the other to release the paddle.
Lift the cover-up and off.
2. Simply put the new paddle onto the switch by side tabs and snap securely
into place.Once this step has been completed please proceed to part 2 wiring.
DESCRIPTION
The MT10N is a timer switch with 6 preset time buttons and 1 Manual ON button.
All Loads connected to this timer will automatically tum OFF when the selected
time expires. The 6 selectable times is 5 Min, 10 Min, 30 Min, 60 Min, 2
Hours, and 4 Hours
FEATURES
Easily replaces a standard single-pole Light or Fan switch.
Compatible with most types of lights.
Attractive blue LED indicators are conweniently located next to each button
for Indoor use only.
Scan to view installation guide
WARNING
Read and understand these instructions before installing. It is recommended
that a qualified electrician performs this installation. Make sure to turn off
the circuit breaker or fuse(s) and make sure power is off before wiring the
device. This device is intended for installation in accordance with the
National Electric Code and local regulations.
Use Copper wires ONLY
OPERATIONS
- Preset Buttons: The LED indicator will blink twice to confirm each button press.
- There are 6 buttons with preset times of 5 Min, 10 Min, 30 Min, 60 Min, 2 Hours, and 4 hours.
- While the Load is OFF, press and release the button with the desired time once to turn the Load on for that selected amount of time.
- When the time expires, the Load will automatically turn off.
- While the Load is ON, press and release the button with the desired time once to restart the countdown with the newly selected time.
- Manual ON Button: The LED indicator will blink 3 times to confirm each button press.
- The Manual ON button is the large button located above the preset buttons.
- While the Load is OFF, press and release the Manual ON button to turn the Load ON with the last selected timer preset.
- While the Load is ON, press and release the Manual ON button to override the timer and turn the Load OFF.
- To hold the Load ON: Press and hold the Manual ON button for 3 seconds.
- The load will turn ON and stay ON. The timer WILL NOT turn the Load OFF.
- Press and release the Manual ON button to turn the Load OFF.
- Press and release the button with the desired time once to keep the Load on for that selected amount of time.
- LED Light: Default, the LED indicator light next to each selected button blinks twice each time it is pressed to mark the time selected
HOW TO INSTALL THE WIRES
1. Unscrew: carefully turn the screw counterclockwise to leave enough space
for the wire to be inserted. Do not unscrew the screws completely.
2. Press down: Once loosened, use your finger so it catches the thread.
3. Insert the wire: make sure the wire is completely straight, then insert it
into the terminal while holding down the screw. Do not wrap the wire around
the screw!
4. Tighten: Turn the screw clockwise to tighten the wire. Make sure the wires
are locked!
Note : There are 2 holes for each terminal that can be used
in the connection. You can use a jumper wire or the second hole at the
terminal to connect.
Single-pole wiring
-
Tool: Please prepare a flat head screwdriver. Single-pole wiring
-
Turn power OFF at circuit breaker or fuse box.
-
Remove wallplate.
-
Remove the switch mounting screws.
-
Disconnect the wires and label them after removing the old switch.(Please use our sticker)
-
Carefully remove the switch from the switch box. (DO NOT disconnect the wires.)
-
There are up to five screw terminals on the smart switch, these are marked (Please check
) -
Fix the wallplate with screws after wiring succeed. (Please use our screws.)
-
The Ground was excluded from the diagram to simplify the illustration. Please Make sure all ground wires are connected to all switches respectively.