Minoston MP21ZD Z-Wave Dimmer Plug User Manual
- June 5, 2024
- Minoston
Table of Contents
MP21ZD Z-Wave Dimmer Plug
User Manual
Specification
Input: 125VAC 60Hz
Frequency: 908.42 MHz
Loading: 200W Incandescent
100W Dimmable CFL/LED
Indoor use in a dry location
Features:
- Z-Wave on/off + dimmer control.
- Grounded 3-wire power connection for safety.
- Remember and restore on/off status after power failure.
- Built-in Z-Wave Plus signal repeater to extend network range.
- S2 security and 700 Z-Wave chip for reliable wireless communication.
- Work with all certificated Z-Wave controllers.
Please contact us if you have any questions:
www.minoston.com
ask@minoston.com
Z-WAVE INTEROPERABILITY
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery-operated nodes within the network will act as repeaters regardless of vendor to increase the reliability of the network. This Device supports Lifeline (association group 1) supporting 1 node for lifeline communication. Group 1 must be assigned the Node ID of the primary controller where unsolicited notifications will be sent. The Z-Wave controller should set this association automatically after inclusion. Lifeline association only supports the “Device Reset Locally” function.
Adding Device To Z-Wave Network for QR CODE
Notes:
-
Plug the device you want to control into the Z-Wave Smart plug-controlled outlet.
NOTE: Plug directly into the outlet, do not use with a power strip.
-
Your device may need to be within 100 feet of the controller to be included. If so, include the device to the network within 10 feet of the controller and relocate it to the desired position in your home. Be sure to refresh the network if the device is included in this manner.
Adding Device To Z-Wave Network
- Follow the instructions for your Z-Wave certified controller to add a device to the Z-Wave network.
- Once the controller is ready to add your device, press the Manual/ Program button on the smart plug 3 times quickly. The blue LED will blink quickly. Auto-add mode: LED will blink within 30 seconds after first plugging in. Now, you have completed control to turn your fixture ON/OFF according to groups, schedules, and interactive automation programmed by your controller. If your Z-Wave certified controller features remote access, you can control your fixture from your mobile devices.
Again: If you have issues with pairing / including, please move the device as close as possible to the hub and try again–you can move to your final location when completed.
Note: If the manual button doesn’t light up after being pressed 3 times, please reset the
Device: click the button twice quickly then hold for at least 10 seconds. This operation could be done when manual control is functional–single press can turn on/off the lamp.
To Remove The Device:
- Follow the instructions for your Z-Wave certified controller to remove a device from the Z-Wave network.
- Once the controller is ready to remove your device, press the manual/program button on the smart plug 3 times quickly.
KWH Reset:
If you’d like to reset the KWH record, just click the button 10 times very
quickly. Network exclusion or factory reset will NOT automatically erase the
KWH data.
To Return The Device To Factory Defaults:
Manual: Click the button twice quickly then hold for at least 10 seconds.
(Light flashes once when reset successfully.)
Host reset: Remove it from the hub the device will be restored to factory
default.
Association Group:
Group 1 supports 1 node ID, Group 2 Supports a maximum of 5 node IDs
Association Group 1: Z-Wave Plus Lifeline Association Group 2: Send Basic Set
ON / Off
Over-temperature protection is protection against overheating of the protected
equipment.
When the device’s temperature is high, the LED will light up in red and cut
down the power.
Please power off the device and use it after the temperature of the device
drops.
Warranty
Our Products warrant this product to be free from manufacturing defects for a
period of one year from the original date of consumer purchase. This warranty
is limited to the repair or replacement of this product only and does not
extend to consequential or incidental damage to other products that may be
used with this product. This warranty is in lieu of all other warranties,
expressed or implied. Some states do not allow limitations on how long an
implied warranty lasts or permit the exclusion or limitation of incidental or
consequential damage, so the above limitations may not apply to you. This
warranty gives you specific rights, and you may also have other rights which
vary from state to state.
Parameter Settings
LED Indicator
This parameter can access you to choose the LED indicator to be on when the
plug(light) is on/off, or LED indicator remains on/off all times. (LED flashes
3 times when the configuration parameter changed.)
— Parameter =2, size =1byte, Default =0
Value=0 (default) LED is On when switch (light) is On.
Value=1 — LED is On when the switch (light) is Off.
Value=2 — LED is always Off.
Value=3 — LED is always On.
Auto Turn-Off Timer
This parameter can access you to set a timer to make the switch turn off
automatically after the switch turns on.
The number entered as a value corresponds to the number of minutes. Operation:
Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =4, Size=4,Value: 0– 65535(minutes); Value=0(default) disable
Auto Turn-On Timer
This parameter can access you to set a timer to make the switch turn on
automatically after the switch is turned on.
The number entered as value corresponds to a number of minutes.
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =6, Size=4,Value: 0– 65535(minutes);
Value=0(default) disable turn on the outlet
Night Light Set
This parameter can access you to set a specific brightness for the light when
you want to make it as a night light.
(LED flashes 3 times when the configuration parameter changed.)
— Parameter =7, Size=1, Default = 2
Value=1 — 10% brightness
Value=2 — 20% brightness/
Value=10 — 100% brightness
Restores state after power failure
This parameter can access you to set the switch to be on/off after power
failure.
Operation: quickly press 8 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=8,Size=1,Value=2(default)
Value=0 — The switch is off regardless of the state prior to power failure.
Value=1 — The switch is on regardless of the state prior to power failure.
Value=2(default) memory state before power failure
This switch will be return to state prior to the power failure after power is
restored.
Dimmer speed (ON/OFF Control)
This parameter can access you to set the time from maximum brightness to
minimum brightness or minimum brightness to maximum brightness (Only when turn
ON / OFF the light )
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=9,Size=1, Default = 2
Value=0 — instant on/off
Value=1— from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 — from 0x63 to 0x00 or from 0x00 to 0x63 need 2s/
Value=10 — from 0x63 to 0x00 or from 0x00 to 0x63 need 10s
Dimmer speed (Dimmer Control)
This parameter can access you to set the time from maximum brightness to
minimum brightness or minimum brightness to maximum brightness.
(Only when holding it to change the brightness or control from HUB).
Operation: Set up on the hub.
(LED flashes 3 times when the configuration parameter changed.)
Parameter=10,Size=1, Default = 4
Value=1 — from 0x63 to 0x00 or from 0x00 to 0x63 need 1s
Value=2 — from 0x63 to 0x00 or from 0x00 to 0x63 need 2s/
Value=10 — from 0x63 to 0x00 or from 0x00 to 0x63 need 10s
The multilevel minimum value can be set
Operation: quickly press 5 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
—Parameter=11,Size=1,Default = 10
Value=0 — disable
Value=1/
Value=99
Multilevel maximum value can be set
Operation: quickly press 10 times to change this parameter.
(LED flashes 3 times when the configuration parameter changed.)
—Parameter=12,Size=1,Default = 99
Value=0 — disable
Value=1/
Value=99
FCC/IC
This device complies with part 15 of the FCC and Industry Canada license-
exempt RSS standard(s). Operation is subjected to the following two
conditions: (1) This device may not cause harmful interference, (2) This
device must accept any interference received, including interference that may
cause undesired operation.
FCC NOTE: The manufacturer is not responsible for any radio or TV
interference caused by unauthorized modifications to this equipment. Such
modifications could void the user’s authority to operate the equipment.
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
CAUTION-PLEASE READ!
This device is intended for installation in accordance with the National
Electric Code and local regulations in the United States, or the Canadian
Electrical Code and local regulations in Canada If you are unsure or
uncomfortable about performing this installation consult a qualified
electrician.
WARNING
RISK OF FIRE / RISK OF ELECTRICAL SHOCK/RISK OF BURNS
TO REDUCE THE RISK OF ELECTRIC SHOCK, THIS PRODUCT HAS A GROUNDING-TYPE PLUG
THAT HAS A THIRD (GROUNDING) PIN. THIS PLUG
IT WILL ONLY FIT INTO A GROUNDING-TYPE POWER OUTLET. IF THE PLUG DOES NOT FIT
INTO THE OUTLET, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL THE PROPER
OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY.
CONTROLLING APPLIANCES: CAUTION: TO REDUCE THE RISK OF OVERHEATING AND
POSSIBLE DAMAGE TO OTHER EQUIPMENT
- DO NOT EXCEED RATINGS
- DO NOT USE TO CONTROL ANY DEVICE
WHERE UNINTENDED OPERATION COULD
CAUSE UNSAFE CONDITIONS (HEAT LAMP, SUN LAMP, ETC.)
MEDICAL EQUIPMENT
Please DO NOT use this switch to control Medical or Life Support equipment.
Z-Wave devices should never be used to control the On / Off status of Medical
and / or Life Support equipment.
CONTROLLING APPLIANCES
Please exercise EXTREME CAUTION when using Z-Wave devices to control
appliances. Reason being is because the appliance you want to control may be
in a separate room and if unintentional behavior occurs (such as a device
turning on or off – either intentionally via schedules, or unintentionally via
network error) this event may lead to a hazardous condition. For these
reasons, please note the following suggestions:
- Do not include Z-Wave devices in Groups or Scenes if they control appliances.
- Do not use Z-Wave devices to control electric heaters or any other appliances which may present a hazardous condition due to unattended, unintentional, or automatic power control.
Command Class Information
GENERIC DEVICE CLASS: 0x10 – SWITCH BINARY
SPECIFIC DEVICE CLASS: 0x00 – NOT_USED
COMMANDCLASS:
0x5E – ZWAVEPLUS_INFO
0x25 – SWITCH_BINARY
0x70 – CONFIGURATION
0x85 – COMMAND_CLASS_ASSOCIATION
0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
0x86 – COMMAND_CLASS_VERSION
0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
0x87 – COMMAND_CLASS_INDICATOR
0x73 – COMMAND_CLASS_POWERLEVEL
0x9F – COMMAND_CLASS_SECURITY_2
0x6C – COMMAND_CLASS_SUPERVISION
0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD