FCC

Federal Communications Commission (FCC) Statement FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body.
IC Caution:
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

WARRANTY

Minoston Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product.
This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you.
This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.
WARNING
RISK OF FIRE
RISK OF ELECTRICAL SHOCK RISK OF BURNS CONTROLLING APPLIANCES:
EXERCISE EXTREME CAUTION WHEN USING Z-Wave® DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave® DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave® DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING.
DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE FOLLOWING:
DO NOT USE Z-Wave® DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.

Specifications

ITEM INFORMATION
Model ZW1304
Power Supply CR2(3V) 1PC
Signal(Frequency) 908.42/920MHz
Range Up to 100 feet line of sight between the Wireless Controller and the

closest Z-Wave® receiver module.
Operating Temperature Range| 5-104° F (-10-40° C)

  • Specifications subject to change without notice due to continuing product improvement
  • Website:

Introduction

This product can be operated in any Z-Wave network with other Z-Wave Plus® certified devices from other manufacturers. This product is a Multipurpose Sensor, it have door/window sensor and Temperature Humidity sensor.
This product is a battery power ,It’s sleep most of the time.
ZW1304 is a security enabled Z-Wave Plus® device. A security Enabled Z-Wave Plus® Controller must be used in order to fully utilize the product.

  • GENERIC_TYPE: GENERIC_TYPE_SENSOR_NOTIFICATION
  • SPECIFIC_TYPE: SPECIFIC_TYPE_NOTIFICATION_SENSOR

Key Features

  • Support Association Group and Auto Report water status.
  • Support firmware upgrades via Over-the-air (need Gateways support)
  • Support SmartStart
  • Support Long Range

Product Overview

A. LED – RGB behind cover
B. Programming button
C. Sensor port
D. Sensor base – use with detachable probe
E. Battery and battery tab ‘
F. Locking tabs
G. Alarm siren
H. Top cover
L Detachable probe
J. S2 security label/ SmartStart OR code

Button Function Description

  • Add/Included into network or Remove/Exclusion from network:
  • Quickly press 1x button Wake-up the device: Quickly press 3x button:

Factory Reset:

  • Remove Battery. Press and hold the manual button, reinsert Battery and continue holding the manual button for 3 seconds. to restore the device to the factory [NOTE] Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Adding Your Device To Hub

  • The device support two methods of inclusion, When using a Z-Wave Plus® certified controller choose Network Wide Inclusion or SmartStart.
  • Network Wide Inclusion To A Z-Wave® Network
  • Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.
  • When prompted by your primary controller, click the z-wave button three times in one second.
  • The device is compatible with SmartStart.

SmartStart enabled products can be added into a Z-Wave® network by scanning the Z-Wave QR Code found on the top of the outlet or the back of the box with a controller providing SmartStart inclusion. No further action is required and the Smart Start product will be added automatically within 10 minutes of being switched on and in the network vicinity.
Z-Wave Long Range device can only support be included via SmartStart. Extract the DSK from end device and paste itinto the DSK Value in PC Controller, make sure the Long Range’ option is ticked.

QR Code and DSK

The QR code are stocked to the side of the case, DSK is included in the QR code.
The DSK code can be found on the DSK label which is attached on the packaging box.

PACKAGE DEVICE

Command Class

Command Class Name Version Required Security Class
Z-Wave Plus Info V2 none
Security 2 V1 none
Supervision V1 none
Transport Service V2 none
Association V2 highest granted
Multi Channel Association V3 highest granted
Association Group Information V3 highest granted
Configuration V4 highest granted
Version V3 highest granted
Manufacturer Specific V2 highest granted
Device Reset Locally V1 highest granted
Power Level V1 highest granted
Firmware Update Meta Data V5 highest granted
Battery V1 highest granted
Indicator V3 highest granted
Notification V8 highest granted
Wake Up V2 highest granted

Basic Set Mapping

  • Basic CC does not map to any Command Class.

Indicator Command Class

  • The indicator (blue color) will flashes according the indicator set command received from HUB.
Indicator ID Property ID
0x50 (NODE IDENTIFY) 0x03(ON OFF PERIOD)
0x50 (NODE IDENTIFY) 0x04(ON OFF CYCLES)
0x50 (NODE IDENTIFY) 0x05(ONE TIME ON OFF PERIOD)

Association Group

ID Name Node Count Profile Function
1 Lifeline 5 General: Lifeline Device Reset Locally Notification:

Issued when Factory Reset is performed.
Battery Report:
Issued periodically to report the current battery level;
Issued when battery becomes low.
Notification Report(Type=0x05;Event=0x02:
Issued when water leak detected.
Indicator Report:
Issued when included successfully.
2| Basic Set| 5| Notification: Water leak detected| Issued 0xff when water leak detected and 0x00 when water leak appear.

Configuration Parameters

Number| Name| Information| Format / Size| Read Only| Altering| Advanced| MIN| MAX| Default
---|---|---|---|---|---|---|---|---|---
3| LED Light Mode| Set the LED Light Mode.| 1 byte unsigned integer| NO| NO| NO| 0| 2| 1
41| LED brightness| Set the LED brightness.| 1 byte unsigned integer| NO| NO| NO| 0| 2| 0
84| Reset Factory Default| Reset sensor to factory defaults.| 1 byte unsigned integer| NO| NO| NO| 0| 1| 0
85| Alarm sound| Set alarm sound.| 1 byte unsigned integer| NO| NO| NO| 0| 2| 1
86| Low Battery Report| Set threshold for Low Battery Report.| 1 byte unsigned integer| NO| NO| NO| 5| 20| 10
87| Low Battery Chirp| Low battery chirp enabled/disabled.| 1 byte unsigned integer| NO| NO| NO| 0| 1| 1
88| Low Battery Chirp interval| Change Number of minutes between low battery chirp sound.| 1 byte unsigned integer| NO| NO| NO| 1| 10| 1
89| Status Reporting| Choose when status reports are sent.| 1 byte unsigned integer| NO| NO| NO| 0| 25| 0

Notification

Type Events Description
Water Alarm(0x05) 0x02(Water leak detected) Water alarm when leak detected

Read User Manual Online (PDF format)