KLEIN TOOLS 93PLL Rechargeable Self-Leveling Green Planar Laser Level Instruction Manual
- June 6, 2024
- KLEIN TOOLS
Table of Contents
KLEIN TOOLS 93PLL Rechargeable Self-Leveling Green Planar Laser Level
Instruction Manual
GENERAL SPECIFICATIONS
Klein Tools 93PLL is a self-leveling laser alignment instrument that can be used to deliver three orthogonal 360° planar lines in the X, Y, and Z planes.
-
Operating Altitude: 6562 ft. (2000 m)
-
Relative Humidity: <80% non-condensing
-
Operating Temp: 20°F to 120°F (-10°C to 50°C)
-
Storage Temp: -5°F to 140°F (-20°C to 60°C)
-
Lasers:
- 510-530 nm
- ≤1mW each beam, Class 2 Laser Product
-
Accuracy: +/- 4.5 mm per 15 m
-
Battery Type: Removable Li-Ion, 3.7V 10400 mAH
-
Battery Life: 9+ Hours (with all three lasers active)
-
Dimensions: 5.5″ x 4.75″ x 3.5″ (140 x 120 x 88 mm)
-
Weight: 22.6 oz. (640 g) without battery
-
Calibration: Accurate for one year
-
Standards: Conforms to: EN61326-1:2013, EN60825 1:2014.
Conforms to NOM-001-SCFI-2018 Electronic Devices: Safety
Requirements and Test Methods, based on NMX-I 60950-1-NYCE-2015
Information Technology Equipment – General Requirements.
Complies with: 21 CFR 1040.10 and 1040.11 except for deviations pursuant to laser notice No. 50, dated June 24, 2007. -
Ingress Protection: IP54 Dust & Water Resistant
-
Electromagnetic Environment: IEC EN61326-1:2013. This equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations. Specifications subject to change.
WARNINGS
To ensure safe operation and service of the instrument, follow these
instructions.
Failure to observe these warnings can result in serious personal injury, fire,
or electrical shock. Retain these instructions for future reference.
WARNING: LASER RADIATION. DO NOT STARE INTO BEAM. Class 2 Laser
Warning label on side
Warning label on bottom
Battery specifications label
WARNINGS
- Exposing eyes to laser radiation can result in severe and permanent eye injuries. NEVER look directly into the laser beam emitted by this instrument.
- Do not use the instrument if it appears to be damaged.
- Do not modify the instrument in any way, as to do so could result in emission of hazardous laser radiation than could result in severe eye injuries.
- Do not use optical equipment such as lenses, prisms, optical scopes, etc. to transmit, retransmit, or view the laser beam as this could result in severe eye injuries.
- This product should not be used by untrained operators or operators who have not read and fully understood the instructions.
- This product should not be used in any location that could result in somebody looking at or having their eyes inadvertently irradiated by the laser beam as this could result in severe eye injuries.
- The instrument should be powered off following use to minimize the risks of inadvertently exposure to hazardous laser radiation that could result in severe eye injuries.
- Do not remove warning labels from this instrument as this could result in serious personal injury and increases the risk of exposure to hazardous laser irradiation.
- The instrument should be securely located in a tidy work environment prior to operation as unexpected drops or movement of the instrument may result in damage to the instrument and increases the risk of inadvertent exposure to laser radiation that could result in severe eye injuries.
- This instrument is IP54 dust & water resistant. Following any contact with water, thoroughly dry the instrument with a dry, lint-free cloth.
- There are no user serviceable parts in this instrument.
SYMBOLS ON INSTRUMENT
X-Plane Laser
|
Ingress Protection IP54 Rating – Dust & Water Resistant
---|---
Y-Plane Laser|
Hazardous laser radiation, DO NOT stare into beam or view direct- ly with optical instruments
Z-Plane Laser
|
Warning or Caution
| |
NOM-NYCE
Out-Of-Level Indicator
|
Warning Risk of electric shock
| |
WEEE Battery disposal
Read instructions
|
Conformité Européenne: Conforms with European Economic Area directives
Recycle
|
Conforms with BCS regulations of California Energy Commission
|
UKCA – United Kingdom Conformity Assessment
FEA TURE DETAILS
NOTE: No user-serviceable parts inside.
- X-Plane Line On/Off Button
- Y-Plane Line On/Off Button
- Z-Plane Line On/Off Button
- Excessive Tilt Indicator
- Battery Level Indicator
- USB-C Charge-In Port
- X-Plane Aperture
- Y-Plane Aperture
- Z-Plane Aperture
- Power/Pendulum Lock/Unlock Switch
- Bracket 1/4-20 Tripod Mount
- Battery Door
- USB-C Charging Cable
- Magnet
- 1/4-20 Mounting Screw
- Li-Ion Battery Charge-In Port
- Li-Ion Battery Charge Indicator LED
OPERATING INSTRUCTIONS
TURNING LASER BEAMS ON/OFF
Push the ON/OFF buttons for the X-Plane 1 , Y-Plane 2 , and Z-Plane
3 lines to turn ON and OFF their respective laser lines. These buttons are
only active once the Pendulum Lock/Unlock Slider Switch 10 has been set to
the Unlocked position. If the Pendulum Slider Switch is moved from the
Unlocked to the Locked position while the laser beams are active, they will be
turned OFF. The different laser lines can be operated independently or
simultaneously.
X-Plane Laser Line
Y-Plane Laser Line
Z-Plane Laser Line
NOTE: The plumb spot can be found by locating the top and bottom laser line intersections while projecting both Y-Plane and Z Plane Laser lines simultaneously. The bottom laser line intersection can be used to locate a specific point on a floor layout while the top laser line intersection projects that same point to a ceiling.
PENDULUM SLIDER SWITCH & SELF LEVELING
The laser assemblies are mounted on a pendulum so that the instrument can
self-level.
The Pendulum Slider Switch 10 must be in the unlocked position for the
instrument to self-level. If the instrument is tilted by >4° from the
horizontal plane, the pendulum will not be capable of self-leveling; the
active laser beams will flash and the Excessive Tilt Indicator 4 will blink to
indicate that the instrument is not level and cannot self-level.
The instrument must be repositioned on a more level geometry for the self-
leveling pendulum to function appropriately.
NOTE: If the instrument indicates that it is not level (via flashing
beams and/or a blinking Excessive Tilt indicator 4 ), then it should not be
used for laying out level or plumb lines.
NOTE: Following use, the active laser beams must be turned OFF and the
Pendulum Slider Switch must be Instrument Tilted Excessively placed in the
Locked position prior to storage.
MAGNETIC MOUNTING BRACKET 14
A magnetic mounting bracket is included with the product. The instrument can
be mounted on the bracket via its 1/4″ threaded screw 15 . The bracket may be
magnetically attached to any ferrous structure such as steel studs, ducts,
structural beams, and steel doors. The bracket also feature a keyhole for
mounting the instrument using a screw or nail to non-ferrous structures. Once
mounted to a structure via the mounting bracket, the instrument can be rotated
on the bracket through 360° to direct the laser beams.
RECHARGING BATTERY
When the Red LED on the Battery Level Indicator blinks, the battery needs to be recharged:
Charging Battery via 93PLL USB-C Port:
- Connect supplied charging cable’s 13 USB-C connection to the USB-C port 6 of the 93PLL.
- Connect the charging cable’s USB-A port to a charging source (5V DC, Min 2.0A, not included).
- The Battery Level Indicator 5 will illuminate to indicate charging status (TABLE 1).
- A full charge can take up to 8.5 hours, depending on the charger’s output. Charge completely before using.
Charging Battery via Battery Pack USB-C Port:
-
Ensure 93PLL is turned off by locking the Power/Pendulum Switch 10 .
-
Loosen screw from the Battery Door 12 and remove battery.
-
Connect the supplied charging cable’s 13 USB-C connection to battery’s Charge-In Port 16 .
-
Connect the charging cable’s USB-A port to a charging source (5.0V, min. 2.0A, not included).
-
Battery Charge Indicator LED
17 will blink red while charging, and turn solid green when fully charged. When fully charged, disconnect cable from battery and reinstall battery in 93PLL. -
Close the battery door and secure with screw. Do not over-tighten.
**Not Illuminated| **
Green
| ****
Yellow
| ****
Red
| ****
Blinking
---|---|---|---|---
LED| Status| % Charged
| Solid green Solid green Solid yellow
Solid red
| **** 100% charged
| Blinking green Solid green Solid yellow
Solid red
| 75% to 99% charged
| Blinking green Blinking green Solid yellow
Solid red|
50% to 74% charged
| Blinking green Blinking green Blinking yellow
Solid red
| **** 25% to 49% charged
| Blinking green Blinking green Blinking yellow
Blinking red
| **** 0% to 24% charged
MAINTENANCE
- Regularly inspect ports and charging cable for and debris, dirt, damage, and corrosion.
- DO NOT attempt to repair device or cable; replace as needed.
CLEANING
Be sure instrument is turned off and disconnected from all power sources. Wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents.
RECHARGING
Recharge as needed. There are no pre-designated intervals at which to recharge as long as you are using the unit regularly. Avoid discharging completely on a regular basis, as this can impact overall life.
STORAGE
If storing for more than one month, charge completely before storage, and
recharge approximately every three months to avoid full discharge. Store in
cool temperatures, mild humidity, and away from direct sunlight (See GENERAL
SPECIFICATIONS section).
Leaving in a vehicle or other confined spaces in extreme hot temperatures can
lead to decrease in service life, overheating, or fire. Extreme cold
temperatures below the specified storage range can also harm performance and
service life. Keep away from corrosive chemicals and gases.
After taking out of storage, inspect visually to make sure device and all
accessories look satisfactory. Allow unit to return to ambient conditions
before recharging.
WARRANTY
http://www.kleintools.com/warranty
DISPOSAL / RECYCLE
Do not place equipment and its accessories in the trash. Items must be
properly disposed of in accordance with local regulations. Please see
www.epa.gov or
www.erecycle.org for additional information.
CUSTOMER SERVICE
KLEIN TOOLS, INC.
450 Bond Street Lincolnshire, IL 60069 1-800-553 4676
customerservice@kleintools.com
www.kleintools.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>