SAFETY INFORMATION
TO AVOID RISK OF SERIOUS INJURY OR DAMAGE, READ AND FOLLOW ALL SAFETY PRECAUTIONS, OTHERWISE, THE WARRANTY WILL BE VOIDED.
WARNING: To prevent overheating, keep the air inlets and outlets clean and free of anything that may cause blockage. Often check all inlets and outlets to ensure they are clear of any dirt or dust accumulation. DO NOT COVER.
WARNING: Parts of the heater may exceed 390ºF, contact with the heating tube, reflector, or mental parts near the heating tube, may cause severe BURNS. DO NOT let bare skin touch hot surfaces. Switch off, unplug and allow the heater to completely cool off before making contact.
WARNING: If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet from the front of the heater and keep them away from the sides and rear.
- DO NOT insert fingers or objects into any of the openings.
- Keep all objects a minimum of 3-ft. away from the heater.
- DO NOT cover the heater, or put objects such as fabrics or combustible materials in contact with the heater.
- DO NOT allow children to play with the appliance. Keep children away unless continuously supervised.
- Check that the voltage in the rating label fits the power supply.
- The use of these heaters is forbidden in any area where there is a presence of gases, explosives, or inflammable objects.
- Neither the connecting cable nor any other object must come into contact with the heater.
- This heater should be switched off at the isolating switch before maintenance or repair work.
- Installation must be carried out by a qualified installer in accordance with current local electrical regulations.
- The heater must not be installed just below an electrical socket outlet.
- Never touch the heater with wet or humid hands or while barefoot.
- DO NOT expose to direct rain/snowfall.
- The supply circuit must incorporate a double-pole isolating switch having a contact separation of at least 1/8”.
- DO NOT operate if the power cord or plug is damaged, after a malfunction, or after the unit has been dropped or damaged in any manner. Disconnect power and have the heater inspected by a reputable electrician before reusing.
- Connect to properly grounded outlets only.
- It is important to maintain a minimum distance of 3-feet between the heater and curtains, or any other combustible materials that will be affected by the radiated heat.
- DO NOT touch the fireguard or reflecting cover when the heater is in use; do not insert any objects into the fireguard to prevent high-temperature scalding.
- Heater for outdoor use only.
- An outdoor weatherproof outlet is recommended.
- NEVER leave the heater unattended while it is operating.
- DO NOT run cord under carpeting, throw rugs, runners, or similar coverings. Do not route the cord under furniture or appliances. Arrange cord away from high traffic areas and where it will not be tripped over.
- DO NOT let the power cable hang over the edge of a table/counter or let it come in contact with hot surfaces.
- DO NOT use an extension cord.
- To disconnect the heater, turn controls off, then remove the plug from the outlet.
- Disconnect heater during installation and maintenance.
- NEVER place hands under the heating elements. ALWAYS allow the heating element to cool at least 10 minutes before touching the heating tube or adjacent parts.
- The heater has hot and arcing or sparking parts inside. Do not use it in areas where gasoline, paint, or flammable liquids are used or stored.
- NEVER dismantle the components of the heater or replace them with components not offered or recommended by Global Industrial.
SPECIFICATIONS:
Model: | 246721 |
---|---|
Voltage: | 110-120 VAC |
Wattage: | 1500W |
Hertz: | 60Hz |
Application: | Outdoor |
Dimensions: | 18-1/8″ L x 3’W x 7-1/2″H |
Weight: | 4.9 lbs. |
INSTALLATION
Tools Required:
- Power Drill and Drill Bits
- Phillips Head Screwdriver
- Hammer
- Level
- Pencil
A wall mounting bracket is provided with the heater. Before drilling holes
make sure the mounting surface (ceiling or wall) is solid and that there are
no hidden water pipes or electric wires behind it.
Allow a minimum of 1-5/8 ft. from each side of the heater to the wall and
5-7/8 ft. off the floor.
WARNING: The heater must be installed on solid surfaces like concrete, wood or metal, etc.
WARNING: Ensure that the supply cable is well mounted and does not come into contact with the reflector of the heater or that does not trail into the heated area. The supply cable can be fixed to the metal mounting bracket behind the heater with plastic zip ties.
- This heater should be installed by a qualified electrician.
- ALWAYS disconnect the heater and allow it to cool before installation/or maintenance.
- Allow a minimum of 5-7/8 ft. from each side of the heater to the wall.
- The distance from the front side of the heater to materials such as wood, carton, cloth, etc., must be a minimum of 3-1/4 ft.
- For ceiling mounting, DO NOT position the heater at an angle more than 90°.
- The power cable must be at the lower end of the heater is installed at an angle or vertically.
- Keep the supply cord away from the body of the heater which will get hot during use.
- DO NOT install the heater on an inflammable surface.
- Observe the minimum safe distance between the heater body and the inflammable surfaces when mounted.
- If the heater is to be used outside, a weatherproof outlet is recommended.
- The heater must be installed on the mounting brackets provided.
- Fasten the brackets securely to the mounting surface and the backside of the heater using the nuts and screws provided.
- The brackets can be used to adjust the direction of the heater, adjust the heater angle by loosening the two bolts on the wall mounting bracket, tighten the bolts again when the desired angle is reached.
Hardware Included:
Ref. | Type | Size | Qty. |
---|---|---|---|
1 | Bracket | U-Shaped | 1 |
2 | Bracket | L-Shaped | 2 |
3 | Nut | 5/16″ | 2 |
4 | Screw | 5/16″ x 1/2″ | 2 |
5 | Plastic Anchor | 5/16″ x 1-1/4″ | 2 |
6 | Screw | 3/16″ x 1″ | 2 |
Wall Mounted Installation:
CLEANING & MAINTENANCE
Regular and careful cleaning helps your infrared heater operate efficiently
for many trouble-free years.
Periodically inspect and remove any dirt or contaminants to ensure that the
equipment can be operated safely. To clean your heater, follow the steps
below:
- Turn off and unplug the power cord.
- Make sure the heater is cool before continuing.
- To keep the heater clean, the outer shell may be cleaned with a soft, damp cloth. You may use a mild detergent if necessary. After cleaning, dry the unit with a soft cloth. WARNING: DO NOT let liquids enter the heater.
- DO NOT use alcohol, gasoline, abrasive powders, furniture polish, or rough brushes to clean the heater. This may cause damage or deterioration to the surface of the heater.
- DO NOT immerse the heater in water.
- Wait until the heater is completely dry before use.
- DO NOT use alcohol, gasoline, abrasive powders, furniture polish, or rough brushes to clean the heater. This may cause damage or deterioration to the surface of the heater.
- DO NOT immerse the heater in water.
- Wait until the heater is completely dry before use.
- Check the filthiness of the Reflector and IR-Filament at least once a month. Clean as needed.
- The frequency of maintenance checks may be increased considering the amount of dust in the environment.
- Check the condition of the Reflector, Wire, and Frame visually while cleaning the appliance. In case of deformation, consult with a qualified electrician.
- Check the Power Cord and Plug visually while cleaning the appliance. In case of damage, consult with a qualified electrician.
STORAGE:
Store the heater in a cool, dry location when not in use to prevent dust and dirt build-up. Use packaging cartons to store.
CAUTION: When the appliance is not operated for a long period of time, cleaning or maintenance is conducted or when transporting, ALWAYS turn off and unplug the heater from the electrical connection.
WARNING:
- Always disconnect the heater from the electricity supply and allow it to cool before attempting to work on it.
- If the heater has collected dust or dirt inside or around the heating element, have the unit cleaned by a qualified service agent. DO NOT operate the heater in this condition.
- The only maintenance required is the cleaning of the external surfaces of the heater.
- DO NOT touch the heating element with bare fingers, as residue from your hand could affect the life of the lamp. If it is accidentally touched, remove the finger marks with a soft cloth moistened with mentholated spirit or alcohol.
- DO NOT attempt to repair or adjust any electrical or mechanical functions on this heater.
- The heater contains no user-serviceable parts. Should the product suffer damage or breakdown, contact Global Industrial.
TROUBLESHOOTING:
If the heater is not working, check the following:
- Make sure the power cord is plugged into an electrical socket properly.
- Make sure there is electricity to the main fuse.
The symbol on the product or in its packaging indicates that this heater may not be treated as household waste. Instead, it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By ensuring this product is disposed of correctly, you will help prevent potential negative consequences for the environment and human health, which could otherwise be caused by inappropriate waste handling of this product. For more detailed information about the recycling of this product, please contact your local city office, your household waste disposal service, or the shop where you purchased the product.
For additional questions or concerns, contact Global Industrial
Customer Service at 1-800-645-2986 or
visit www.globalindustrial.com