- June 6, 2024
- Hama
Table of Contents
- hama 00186346 TS35C Outdoor Sensor
- Operating instruction
- Explanation of Warning Symbols and Notes
- Package Contents
- Safety Notes
- Getting started
- Installation
- Operation
- Care and Maintenance
- Warranty Disclaimer
- Technical Data
- Recycling Information
- Declaration of Conformity
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
hama 00186346 TS35C Outdoor Sensor
Operating instruction
Controls and Displays
A Measuring station
- LED indicator
- Battery compartment
- RESET button = restores factory settings
- CHANNEL slide switch = selects channel
- Recess for wall mounting
- LCD display
Thank you for choosing a Hama product.
Take your time and read the following instructions and information completely.
Please keep these instructions in a safe place for future reference. If you
sell the device, please pass these operating instructions on to the new owner.
Explanation of Warning Symbols and Notes
Warning
This symbol is used to indicate safety instructions or to draw your attention
to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.
Package Contents
- TS35C Outdoor Sensor
- These operating instructions
Safety Notes
- The product is intended for private, non-commercial use only.
- Do not operate the product outside the power limits given in the specifications.
- Do not use the product in moist environments and avoid splashes.
- Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
- Do not use the product in areas where the use of electronic devices is not permitted.
- Do not put the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the product’s functionality.
- Do not drop the product and do not expose it to any major shocks.
- Do not open the device or continue to operate it if it becomes damaged.
- Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
- Keep the packaging material out of the reach of children due to the risk of suffocation.
- Dispose of packaging material immediately according to locally applicable regulations.
- Do not modify the product in any way. Doing so voids the warranty.
Warning – Batteries
- When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
- Only use batteries (or rechargeable batteries) that match the specified type.
- Before you insert the batteries, clean the battery contacts and the polar contacts.
Warning – Batteries
- Do not allow children to change batteries without supervision.
- Do not mix old and new batteries or batteries of a different type or make.
- Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
- Do not short-circuit batteries.
- Do not charge batteries.
- Do not throw batteries in a fire.
- Keep batteries out of the reach of children.
- Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
- Immediately remove and dispose of dead batteries from the product.
- Avoid storing, charging or using the device in extreme temperatures and extremely low atmospheric pressure (for example, at high altitudes).
Getting started
- Open the battery compartment (2).
- Move the CH slide switch (4) to the left or right to select the channel on which the measuring station transmits.
- Insert two AA batteries with the correct polarity.
- Once the channel has been assigned to a transmitter, it can only be changed by removing the batteries or by resetting the measuring station (see section 6.5 Reset).
- Then close the battery compartment cover.
Replacing the batteries
Open the battery compartment (2), remove and properly dispose of the dead batteries and insert two new AAA batteries with the correct polarity. Then close the battery compartment cover.
Note
Before use, make sure that you insert the batteries in the measuring station
first and then in the base station.
Installation
Note – Installation
- We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6. Operation.
- Only install the stations once the appropriate settings have been made and a stable wireless connection is established.
Note
- The wireless transmission range between the measuring and base stations is up to 50 metres in open spaces. Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, high-voltage lines, etc.
- Before the final installation, ensure that there is sufficient reception between the intended installation locations.
- When installing the measuring station, ensure that it is protected from direct sunlight and rain.
Note
- The international standard height for measuring air temperature is 1.25 m (4 ft) above ground.
Warning – Batteries
- Buy special or suitable installation material from a specialised dealer for wall-mounting.
- Ensure that no faulty or damaged parts are installed.
- Never apply force during installation. This could damage the product.
- Before installation, ensure that the chosen wall is suitable for the weight to be installation, and make sure that there are no electrical wires, water, gas or other lines in the wall at the installation site.
- You can position the measuring station on a level outdoor surface using the base.
- We recommend installing the measuring station securely on an outdoor wall.
- Install an anchor, screw, nail, etc. in the wall of your choice.
- Hang the measuring station using the opening intended for this purpose (4).
Operation
Connection to the measuring station
- To connect the base station and the measuring station, place the two devices as close together as possible.
- After you insert the batteries, the base station automatically searches for a connection to the measuring station and performs initial setup.
- If the device does not connect automatically, the manual search program on the base station must be started.
Note
- Initial setup takes approximately 5 minutes.
- During the connection attempt, the radio symbol and the LED indicator (1) on the measuring station will flash.
- Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
- The setup process is completed when the indoor and outdoor measurement data is displayed on the base station.
- The measured value is automatically updated by the base device about every 60–64 seconds.
Selecting the channel/Other measuring stations
Note
- Ensure that the base station and measuring station are set to the same channel. Suitable base stations can be found at www.hama.com
- The transmission channel on the supplied measuring station can be changed/set (CH1, CH2, CH3).
- The measuring station is suitable for the following base stations: 00113984, 00113985, 00113986, 00186309
Low battery charge
Once the battery symbol appears on the display of the base station, the capacity of the batteries in the measuring station is very low. Replace the batteries immediately.
Note – Replacing the batteries
- Note that the stations have to be resynchronized each time after you change the batteries in the measuring or base station.
- To do this, remove the batteries from the other station and then reinsert them, or change them as required.
Reset
Press the RESET button (3) to restart the station. The measuring station returns to the factory settings.
Care and Maintenance
- Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents.
- Make sure that water does not get into the product.
Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no warranty for damage
resulting from improper installation/mounting, improper use of the product or
from failure to observe the operating instructions and/
or safety notes.
Technical Data
|
Measuring station
---|---
Power supply| 1.5 V
2x AA batteries
Measuring range Thermometer Hygrometer Barometer| ****
-40°C – +70°C/ -40°F – 158°F 20 – 90
Measurement increments Temperature
Humidity
| 0,1°C / °F
1
Measuring cycle thermometer/hygrometer Barometer| ~ 60- 64s
–
Hygrometer| Yes
Thermometer| Yes
Barometer| No
Moon phases| –
Frequency| 433 MHz
Radio-frequency power transmitted| 0,018 µW
Range| ≤ 50 m
Recycling Information
Note on environmental protection:
After the implementation of the European Directive 2012/19/ EU and 2006/66/EU
in the national legal system, the following applies: Electric and electronic
devices as well as batteries must not be disposed of with household waste.
Consumers are obliged by law to return electrical and electronic devices as
well as batteries at the end of their service lives to the public collecting
points set up for this purpose or point of sale. Details to this are defined
by the national law of the respective country. This symbol on the product, the
instruction manual or the package indicates that a product is subject to these
regulations. By recycling, reusing the materials or other forms of utilising
old devices/batteries, you are making an important contribution to protecting
our environment
Declaration of Conformity
Hereby, Hama GmbH & Co KG declares that the radio equipment type [00186346, 00176932] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.hama.com ->00186346, 00176932 ->Downloads.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>