Controls and Displays
A Measuring station
-
LED indicator
-
Battery compartment
-
RESET button
= restores factory settings -
CHANNEL button = channel selection
-
Recess for wall mounting
-
°C/°F button = switches between °C and °F
-
LCD display
1. Explanation of Warning Symbols and Notes
Warning
This symbol is used to indicate safety instructions or to draw your attention to specific hazards and risks.
Note
This symbol is used to indicate additional information or important notes.
2. Package Contents
- TS33C Outdoor Sensor
- These operating instructions
3. Safety Notes
- The product is intended for private, noncommercial use only.
- Do not operate the product outside the power limits given in the specifications.
- Do not use the product in moist environments and avoid splashes.
- Do not use the product in the immediate vicinity of heaters or other heat sources or in direct sunlight.
- Do not use the product in areas where the use of electronic devices is not permitted.
- Do not put the product near interference fields, metal frames, computers, TVs, etc. Electronic devices and window frames can negatively affect the product’s functionality.
- Do not drop the product and do not expose it to any major shocks.
- Do not open the device or continue to operate it if it becomes damaged.
- Do not attempt to service or repair the product yourself. Leave any and all service work to qualified experts.
- Keep the packaging material out of the reach of children due to the risk of suffocation.
- Dispose of packaging material immediately according to locally applicable regulations.
- Do not modify the product in any way. Doing so voids the warranty.
- Protect the product from dirt, moisture and overheating, and only use it in a dry environment.
Warning – Batteries
- When inserting batteries, note the correct polarity (+ and – markings) and insert the batteries accordingly. Failure to do so could result in the batteries leaking or exploding.
- Only use batteries (or rechargeable batteries) that match the specified type.
- Before you insert the batteries, clean the battery contacts and the polar contacts.
- Do not allow children to change batteries without supervision.
- Do not mix old and new batteries or batteries of a different type or make.
- Remove the batteries from products that are not being used for an extended period (unless these are being kept ready for an emergency).
- Do not short-circuit batteries.
- Do not charge batteries.
- Do not throw batteries in a fire.
- Keep batteries out of the reach of children.
- Never open, damage or swallow batteries or allow them to enter the environment. They can contain toxic, environmentally harmful heavy metals.
- Immediately remove and dispose of dead batteries from the product.
- Avoid storing, charging or using the device in extreme temperatures and extremely low atmospheric pressure (for example, at high altitudes).
4. Getting Started
Inserting the battery
- Open the battery compartment (2), insert the batteries with the correct polarity and close the battery compartment (2). The outdoor sensor is now ready for operation.
Replacing the batteries
- Open the battery compartment (2), remove and properly dispose of the dead batteries and insert two new AA batteries with the correct polarity. Then close the battery compartment cover.
Note
Before use, make sure that you insert the batteries in the measuring station first and then in the base station.
5. Installation
Note – Installation
-
We recommend initially placing the base and measuring stations in the intended locations without installing them and making all the settings described in 6. Operation
-
Only install the stations once the appropriate settings have been made and a stable wireless connection is established.
-
Do not mount the product above locations where persons might linger.
Note
- The wireless transmission range between the measuring and base stations is up to 30 metres in open spaces. Before installation, ensure that wireless transmission will not be disrupted by interference or obstacles like buildings, trees, vehicles, highvoltage lines, etc.
- Before the final installation, ensure that there is sufficient reception between the intended installation locations.
- When installing the measuring station, ensure that it is protected from direct sunlight and rain.
- The international standard height for measuring air temperature is 1.25 m (4 ft) above ground.
Warning
- Buy special or suitable installation material from a specialised dealer for wall-mounting.
- Ensure that no faulty or damaged parts are installed.
- Never apply force during installation. This could damage the product.
- Before installation, ensure that the chosen wall is suitable for the weight to be installation, and make sure that there are no electrical wires, water, gas or other lines in the wall at the installation site.
- You can position the measuring station on a level outdoor surface using the base.
- We recommend installing the measuring station securely on an outdoor wall.
- Install an anchor, screw, nail, etc. in the wall of your choice.
- Hang the measuring station using the opening intended for this purpose (5).
6. Operation
6.1. Default setting
- After opening the battery compartment, first choose the channel using the CHANNEL button.
- Only then, insert the batteries into the battery compartment with the correct polarity.
- Press the RESET button.
- Then replace the battery compartment on the outdoor sensor.
6.2. Connection to the measuring station
- To connect the measuring station and the outdoor sensor, place the two devices as close together as possible.
- After you insert the batteries, the base station automatically searches for a connection to the measuring station and performs initial setup.
- If the device does not connect automatically, the manual search program on the base station must be started.
Note
- Initial setup takes approx. 2 minutes.
- During the connection attempt, the measuring station radio symbol (1) will flash.
- Do not press any buttons during setup. Otherwise, values may not be transmitted correctly and there is a risk of value errors and inaccuracies.
- The setup process is completed when the indoor and outdoor measurement data is displayed on the base station.
- The measured value is automatically updated by the base device about every 45 seconds.
- If the temperature is outside of the measuring range, LL.L (lower than minimum temperature) or HH.H (higher than maximum temperature) will appear on the temperature display.
6.3. Selecting the channel/Other measuring stations
Note
- Ensure that the base and measuring stations are set to the same channel. Visit www.hama.com for suitable measuring stations.
- The transmission channel on the supplied measuring station can be changed/set (CH1, CH2, CH3).
6.4. Low battery charge
Measuring station
If the batteries need to be replaced, the symbol for low battery charge will appear next to the outdoor temperature display on the base device. Replace the batteries immediately.
Note – Replacing the batteries
- Note that the stations have to be resynchronised each time after you change the batteries in the measuring or base station.
- To do this, remove the batteries from the other station and then reinsert them, or change them as required.
6.5. Reset
Press the RESET button (3) to restart the station. The measuring station returns to the factory settings.
7. Care and Maintenance
- Only clean this product with a slightly damp, lint-free cloth and do not use aggressive cleaning agents.
- Make sure that water does not get into the product.
8. Warranty Disclaimer
Hama GmbH & Co KG assumes no liability and provides no warranty for damage resulting from improper installation/ mounting, improper use of the product or from failure to observe the operating instructions and/or safety notes.
9. Technical Data
10. Declaration of Conformity
Hereby, Hama GmbH & Co KG declares that the radio equipment type [00186300, 00104985] is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.hama.com->00104985 ->Downloads.
Recycling Information
Note on environmental protection:
After the implementation of the European Directive 2012/19/EU and 2006/66/ EU in the national legal system, the following applies: Electric and electronic devices as well as batteries must not be disposed of with household waste. Consumers are obliged by law to return electrical and electronic devices as well as batteries at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual or the package indicates that a product is subject to these regulations. By recycling, reusing the materials or other forms of utilising old devices/batteries, you are making an important contribution to protecting our environment.
Hama GmbH & Co KG
86652 Monheim/ Germany
Service & Support
www.hama.com
+49 9091 502-0
All listed brands are trademarks of the corresponding companies.
Errors and omissions excepted, and subject to technical changes.
Our general terms of delivery and payment are applied.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>