N.B. This equipment must be installed by a competent person and a risk
assessment undertaken as to the suitability of the chair for the particular
user.
127 kg (20 st) weight limit
Do not exceed the weight limit stated as doing so could put the user at risk
ASSEMBLY
The chair is provided to you packed in cube form. Please examine all
components for any visible damage before use. If you see any damage or suspect
a fault, please contact your supplier immediately.
In this case, please do not use your product as it may compromise the safety
of the user.
NB. When transferring sideways from the chair, a risk assessment may be needed
as to the suitability of the chair for the particular user.
NB. Arm rests are for comfort only.
NB. Indoor use only.
NB. When pushing the chair, attendants must not ‘ride’ (i.e. put all their
weight) on the pram handle.
The package contains the following components:
- The main frame with two braked castors (front) attached
- Detachable grey horseshoe aperture seat (attached to the main frame)
- Grey horseshoe seat infill
- Detachable back
- Detachable footrests
- 580 mm diameter puncture proof tyres (self propelled model only)
PLEASE READ THESE FOLLOWING INSTALLATION INSTRUCTIONS CAREFULLY.
- Remove all contents from the box
- Remove the white cardboard packing tubes taped around the frame (this is to prevent damage during transit and not part of the chair)
- Place the assembled base on a level floor
- At the rear of the chair (or removable back) you will see two black threaded wheel nuts; undo the wheel nuts and remove from the frame
- Place the two legs of the back into the locating holes at the rear of the chair frame
- Re-insert the black nuts through the frame and back and secure by turning the black lock nuts until you feel the nut biting against the leg of the back
- Do not over tighten
- Do not use tools as it is only necessary to have the back secured finger tight
FOOTRESTS
Your footrests may be packed separately to the main chair. Please examine your
footrests for any visible damage before use. If you see any damage or suspect
a fault, please contact your supplier immediately. In this case, please do not
use your product as it may compromise your safety.
- Remove the footrests from their packaging.
- You will see on each of the front legs of the main frame about 150 mm high from the castor 2 retaining lugs either side.
- Take the footrests and align the holes in the inverted ‘U’ section with the lugs and lower down into place.
- Rotate the footrests towards the commode so that they clip into place.
BRAKED CASTORS
Do not attempt to push the Bewl shower chair with the brakes applied, this
will damage the brake mechanism and may compromise the safety of the user.
NB. Please regularly check the castors and the brakes for proper operation.
CASTOR REPLACEMENT
NB: We recommend castor replacement is done by Aidapt or a qualified
technician
- Remove the existing castors using a short reach 8 mm Allen key (available from Aidapt).
- Replacement M12x35 bolts are provided with each castor, the removed bolts should be disposed of.
- Apply a thread locking fluid to the bolt to lock the assembly securely. We recommend the use of Bondloc B243 or Locktite 243.
- Assembly should be screwed tightly and the castor should sit flush with the frame.(i.e. there should be no gap between the castor and the frame)
NB: Where leg extension pins are in place it is recommended that the
extension pins are replaced at the same time as the castor.
For further technical details contact Aidapt.
SEAT
The Bewl comes with a detachable grey horseshoe seat (see Fig. 1) as standard.
A pear shaped aperture seat is also available (see Fig. 2) and may be required
by the user, based on the risk assessment.
APERTURE COVER
When transferring to and from the Bewl Shower Chair be careful not to apply
weight to the grey removable toileting aperture cover. This may cause the
padded aperture cover to push through.
NB. The padded aperture cover is not designed to be load bearing.
SELF PROPELLED WHEELS
On the self propelled model, the 580 mm diameter rear wheels are packed
separately. The wheels are attached to the frame by the large square silver
brackets on the rear vertical legs of the frame.
- Remove the wheels from their packaging.
- Hold the wheel in position against the silver bracket so that the centre of the wheel is against the locating hole in the bracket.
- Press the black button in the centre of the wheel to pass the locking bar axle through the bracket into the frame. Do not apply excessive force – when positioned correctly it should slide gently into the locating hole.
- Continue to apply pressure until the button clicks into place and will move no further.
- Check that the wheel is correctly installed by pulling it away from the frame – if correctly installed the wheel will remain attached: If the wheel comes away from the frame follow steps 2 – 4 again until it is correctly installed.
COMMODE BUCKET
To remove the commode bucket, simply slide the bucket out from the chrome
runners at the rear of the commode. Cover the top of the bucket to avoid
splashing, carefully dispose of the contents into a proper sluice or WC. Never
use an open drain, sink or basin. This could cause a serious health risk. To
avoid the possibility of trapping, do not slide the commode pan on or off the
rails while somebody is sitting on the chair.
Clean out the residue with a suitable disinfectant and refit to the commode
after use NB. Always remove the commode bucket prior to removing the grey
horseshoe seat.
CLEANING
A useful guide to decontamination is MHRA leaflet DB2003(06).
Do not use abrasive cleaners as this could damage the surface of the
equipment. For cleaning, wipe with a clean cloth soaked in detergent solution
and wring out. Depending on the detergent manufacturer’s instructions the
solution may be heated.
Wipe all surfaces of the equipment and the cloth should be re-immersed
periodically and the detergent changed frequently. The detergent should be
rinsed or wiped off using a clean cloth immersed in clean water and wrung out.
To disinfect make sure the equipment has been cleaned and dried and then wipe
over with a clean cloth and a compatible liquid disinfectant. After
disinfecting clean with clean water and dry.
When using detergent or disinfectants then please refer to manufacturers’
instructions and if unsure then consult your local Infection Control
Specialist for advice.
This product is not suitable for cleaning with moist heat or autoclaving.
APERTURE COVER
When transferring to and from the Bewl Shower Chair, be careful not to apply
weight to the grey removable toileting aperture cover. This may cause the
padded aperture cover to push through.
NB. The padded aperture cover is not designed to be load bearing.
REISSUE
If you reissue or are about to reissue this product, please thoroughly check
all components for their safety, also check all upholstery for security,
splits, etc. If in any doubt, please do not issue or use, but immediately
contact your supplier for service support.
When reissuing, a risk assessment may be required as to the suitability of the
chair for a particular user.
MAINTENANCE
Please make a safety check of the product at regular intervals or if you have any concerns, paying particular attention to the castors.
IMPORTANT INFORMATION
The information given in this instruction booklet must not be taken as forming
part of or establishing any contractual or other commitment by Aidapt
Bathrooms Limited, Aidapt
(Wales) Ltd or its agents or its subsidiaries and no warranty or
representation concerning the information is given.
Please exercise common sense and do not take any unnecessary risks when using
this product; as the user you must accept liability for safety when using the
product.
Please do not hesitate to contact the person who issued this product to you or
the manufacturer (detailed below) if you have any queries concerning the
assembly/use of your product.
Aidapt Bathrooms Ltd, Lancots Lane, Sutton Oak, St Helens, WA9 3EX Telephone:
+44 (0) 1744 745 020 | Fax: +44 (0) 1744 745 001 | Web:
www.aidapt.co.uk
Email: accounts@aidapt.co.uk |
adaptations@aidapt.co.uk |
sales@aidapt.co.uk
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>