wallas 88DU PI Thermo Control Panel User Guide

October 27, 2023
wallas

wallas-800-DSL-PI-Thermo-Control-Panel-logo-

wallas 800 DSL PI Thermo Control Panel

wallas-800-DSL-PI-Thermo-Control-Panel-logo

Please Refer to Manual for Full Operation and Maintenance Instructions at wallas.com

IGNITION

Press the Power Button for 3 seconds until the yellow power light will come on. When you release the button, the yellow heating light will appear.

Red combustion light will light up when the burner flame has been ignited and the combustion has stabilized (approx. in 5 min). Stove will be fully operational about 10 min later.
Stove is set to always start in Manual Mode ready for cooking.

COOKING

In Manual Mode, turn the Temperature/Power Knob to max. level 6 and begin cooking. Adjust it to a lower temperature, if needed, as you would a domestic stove.

When Manual Mode for cooking is on, the orange Thermostat light is off.

wallas-800-DSL-PI-Thermo-Control-Panel-02

  1. Combustion indicator

  2. Temperature knob

  3. Power button

  4. Power indicator

  5. Thermostat indicator
    (Not in use in the 88 DU model)

  6. Thermostat sensor
    (Not in use in the 88 DU model)

  7. Heating indicator

HIGH ALTITUDE MODE

When the device is used 1500 m (4,900 ft) above sea level, it is necessary to activate the High Altitude Mode to adjust the combustion.

Start the stove by holding the Power Button down for 10 seconds.

Yellow heating light will flash 3 times and then change to a solid yellow light. High Altitude Mode is now on and the stove has started the ignition process.

SHUTDOWN

Press the Power Button down for 2 seconds. Yellow heating light will shut off immediately.

Red combustion light will continue to flash for about 5 minutes, while the stove is cooling down. Unit cannot be restarted until the cool down is completed.

All rights reserved. Wallis-Marin reserves the right to change or improve its products and to make changes in the content of this guide without obligation to notify any person or organization of such changes or improvements. Go to www.wallas.com for current updates and supplemental information concerning the use of this product

PANEL LIGHTS

  • Heating on
  • Heating on in High Altitude Mode
  • Combustion has begun/is running
  • Cooldown/Flameout
  • Low voltage (usually about 15 sec after initiating start)
  • Overheat
  • Reminder indicating there was a fault after fault code flashed for 5 min
  • Locked for security
  • The device locks itself after two unsuccessful starts

wallas-800-DSL-PI-Thermo-Control-Panel-11

UNLOCKING THE UNIT

If the unit has locked itself, the combustion light (1) and the heating indicator light (7) will flash signaling there has been a failure that should be investigated and resolved prior to further use. Lights will flash for about 5 min.

  1. While the lights are still flashing, switch the main power off from the battery (Pull power plug, remove the fuse, open breakers, or in-line switch).
  2. Wait for 5 sec. and switch the main power back on.
  3. Press Power Button (3) for more than 3 seconds to shut down the unit.
  4. Restart the unit normally.

See instructional video to unlock

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

wallas User Manuals

Related Manuals