SOtM sPQ-100 Phono Preamp Instruction Manual
- June 10, 2024
- SOtM
Table of Contents
SOtM sPQ-100 Phono Preamp Instruction Manual
Precaution
Please read these instructions carefully before use.
- Do not attempt to disassemble or modify the product.
- Keep the product away from external shocks or vibrations.
- Do not use damaged or peeled cables.
- Do not use the product outdoors.
- Product specifications and features are subject to change without notice.
Warranty Information
- Free warranty service
- In the case that a defect is found which is caused by a design or the production flaw while using the device properly, the manufacturer is responsible for the faulty product and there is free warranty service for 1 year from the date of purchasing.
- Even during the warranty service period, malfunction or damage of products caused by inevitable incidents such as a natural disaster is not subject to the free warranty service
- Warranty service at a cost
- The free warranty service period is expired.
- Malfunction of the product caused by a user’s fault.
- Malfunction of the product caused by incidents.
- Malfunction of the product caused by a natural disaster such as earthquake, flood, lightning & etc.
- In case of the warranty service at a cost, the customer should cover the shipping costs.
- Examples of a user’s fault
- In case of attempts to disassemble or modify the device.
- In case of not following the instructions in this manual.
- Please read these operating instructions and Q&A board on our website carefully before asking for the warranty service
Supplied Components
- A sPQ-100 Unit
- A 9V adaptor
- sPQ-100 Operating instructions
Specification
-
User interface
-
Power on/off switch
-
Operating indicator LED x1
-
MM/MC selection switch
-
Input impedance/capacitance selection switch
MM : 47KΩ, 100pF, 150pF, 220pF, 330pF
MC : 15Ω, 20Ω, 100Ω, 500Ω, 10pF -
Bass boost level selection switch
14.5dB, 16dB, 20dB @ 20Hz, 33dB @ 7Hz(no bass shelf) -
Bass turnover frequency selection switch
250Hz, 354Hz, 500Hz, 800Hz -
High frequency roll off frequency selection switch
1592Hz, 2122Hz, 2500Hz, 3183Hz -
Total gain selection switch
40dB, 50dB, 60dB, 70dB @ 1KHz -
Tolerance : ±10%(all switch location)
-
-
Input/Output signal
-
Input signal
Stereo RCA jack with earth terminal x 1
MM input
Signal level : 3mVac ~ 10mVac @ 1KHz
Recommended impedance : 47KΩ
Recommended capacitance : 100pF ~ 330pF
Frequency response : 20Hz ~ 20KHz
MC input
Signal level : 0.1mVac ~ 1mVac @ 1KHz
Recommended impedance : 15Ω ~ 500Ω
Frequency response : 20Hz ~ 20KHz -
Output signal
Stereo RCA jack
Output signal level : 9.5Vac Max
Output impedance : 20Ω typical
Frequency response : 20Hz ~ 20KHz
SNR : 100dB typical @ 1KHz max output level (MC, RIAA, 50dB Gain setting) -
Tolerance : ±10%(all signal level, gain and frequency)
-
-
DC power input
- Input voltage : 7Vdc ~ 9Vdc
- Input current : 1A max
- 5.5mm OD, 2.1mm ID adaptor jack
-
Operating environment
- Operating temperature : 0 ~ +40℃
- Storage temperature : 0 ~ +40℃
- Operating & storage humidity : 10% ~ 90%
-
Dimension
- 106 x 48 x 245(mm)
-
Weight
- 1.5kg >
Product Outlines
-
Power on/off switch and power lamp : The lamp blinks several times when connected power to the unit, then, the lamp lights out and the unit is in turn off status. To turn on the unit, press the switch for about 0.5 seconds, then, the lamp will blink for about 10 seconds and continue light up. To turn off the unit, press the switch for about 0.5 seconds, then, the lamp will blink for about 2 seconds and light out.
-
Power input jack: Connect to the power supply.
-
Audio input jack : Connect to audio output jack of a record player.
-
Audio output jack : Connect to audio input jack of a pre-amp or inti-amp.
-
Earth Terminal : Connect to earth terminal of a record player.
-
MM/MC selection switch : Set the MM or MC per a cartridge type of a record player.
-
Input impedance/capacitance selection switch:
When set to MC, MC impedance value is set by the switch position.
When set to MM, MM capacitance values is set by the switch position. -
High frequency roll off frequency selection switch : High frequency roll off frequency is set by the switch position.
-
Bass turnover frequency selection switch : Bass turnover frequency is set by the switch position.
-
Bass boost level selection switch : Bass boost level is set by the switch position.
-
Total gain selection switch : Total gain is set by the switch position.
How to use
Precautions
- Please read these operating instructions fully before installing the unit.
- Please turn off all audio devices and disconnect AC power cables from all audio devices before installing the unit.
- Please check output and input connectors and connect cables correctly.
Installations
- Make sure to turn off all audio devices.
- Disconnect AC power cables from all audio devices.
- Connect the Earth terminal of a record player and the earth terminal of the sPQ-100 with a earth cable. And tighten the earth terminal so that it does not come loose.
- Connect audio output jack of a record player and the audio input jack of a sPQ-100 with an inter cable.
- Connect the audio output jack of a sPQ-100 and the audio input jack of a pre-amp or inti-amp.
- Set the MM or MC per a cartridge type of a record player, and set MC impedance or MM capacitance.
- Refer to the enclosed sPQ-100 EQ characteristics and select the desired EQ graphs by setting the switches on the top of the sPQ-100 according to the specifications of the record you want to listen to.
- Turn on the unit by pressing the switch for about 0.5 seconds, then, the lamp will blink for about 10 seconds and continue light up.
- Turn the volume down on the audio system, then turn on all audio devices.
- Put a record into the record player and start playing.
- Set the volume of a pre-amp or inti-amp gradually and fix the volume to listen to music.
- When turning off the sPQ-100, make sure turn off the power-amp and pre-amplifier first, then press the switch on the front of the sPQ-100 to turn off.
LP record EQ table by Switch settings
EQ Graph Spec.| HIGH FREQUENCY ROLL-OFF| BASS TURNOVER
FREQUENCY| BASS BOOST LEVEL| Note
---|---|---|---|---
RIM| 2122Hz| 500Hz| 20dB|
AES| 2500Hz| 354Hz| 33dB|
NARTB(NAB)| 1592Hz| 500Hz| 33dB|
TELDEC| 3183Hz| 500Hz| 20dB|
CCIR 78| 3183Hz| 354Hz| 33dB|
IEC N78| 3183Hz| 354Hz| 16dB|
Columbia LP| 1592Hz| 500Hz| 14.5dB|
RCA Old Orthophonic| 2122Hz| 500Hz| 33dB|
LONDON LP| 3183Hz| 500Hz| 14.5dB|
| | | |
| | | |
| | | |
| | | |
All settings tolerance are ±1 dB with ideal values at 50Hz, 1KHz, 10Khz
EQ characteristics per sPQ-100 Switch setting
-
BASS BOOST LEVEL switch
-
BASS TURNOVER FREQUENCY switch
-
HIGH FREQUENCY ROLL-OFF switch
-
TOTAL GAIN graph
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>