Gude GP, HWA, HWW Series Garden Water Pump Instruction Manual

October 27, 2023
Gude

GP, HWA, HWW Series Garden Water Pump
Instruction Manual
Translation of the original instructions GP 600 VFP 06028 GP 1100 VF 94228
HWA 800 VFP 06030 HWA 1100 VF 94226
HWW 600 VF P 06032 HWW 1100 VF 94230
HWW 1400 VF 94231 HWW 1400 VF INOX 94232

DELIVERED ITEMS

Please read the instructions carefully before starting the machine.

Service international

Gude GP HWA HWW Series Garden Water Pump - fig
1

| STARTING-UP THE MACHINE
---|---
| SERVICE CONNECTION
| ENGINE PROTECTION
| OPERATION
| MAINTENANCE
| TRANSPORT / STORAGE
| STARTING-UP THE MACHINE

STARTING-UP THE MACHINEGude GP HWA HWW Series Garden Water Pump - fig
9

SERVICE CONNECTIONGude GP HWA HWW Series Garden Water Pump - fig
11

ENGINE PROTECTION

OPERATION

Gude GP HWA HWW Series Garden Water Pump - fig 13

MAINTENANCE TRANSPORT / STORAGE

Technical Data

Garden pump

| | | Domestic water supply system
---|---|---|---
GP 600 VF P| GP 1100VF| HWA 800 VF P| HWA 1100 VF| HWA 1100 VF
Art. No| 6028| 94228| 6030| 94226
Service connection| 230V/ 50Hz| 230V/ 50Hz| 230V/ 50Hz| 230V/ 50Hz
Motor output P1| 600W| 1100 W| 800 W| 1100 W
Max. delivered quantity| 3600 l/h| 3600 l/h| 3600 l/h| 3600 l/h
Max. head of delivery| 35m| 45 m| 40 m| 45 m
Max. suction head| 8m| 8 m| 8 m| 8 m
35°C Max. Water temperature| 35°C| 35°C| 35°C| 35°C
Hose connection| 1“ IG| 1“ IG| 1“ IG| 1“ IG
IPX4 Degree of protection| .IPX4| IPX4| IPX4| IPX4
Weight| 11,0 kg| 12,5 kg| 12,5 kg| 14,5 kg
Sound power level| 90 dB| 90 dB| 90 dB| 90 dB

Domestic water supply unit

| HWW 600 VF P| HWW 1100 VF| HWW 1400 VF| HWW 1400 VF INOX
---|---|---|---|---
Art. No| 6032|  94230| 94231| 94232
Service connection| 230V/50Hz| 230V/50Hz| 230V/50Hz| 230V/50Hz
Motor output P1| 600 W| 1100 W| .1400 W| 1400 W
Max. delivered quantity| 3600 l/h.|  3600 l/h| 3900 l/h| 3900 l/h
Max. suction head| 8 m| 8 m| 8 m| 8 m
Max. Water temperature| 35°C| 35°C| 35°C| 35°C
Hose connection| 1“ IG| 1“ IG| 1“ IG| 1“ IG
IPX4 Degree of protection| IPX4| IPX4| IPX4| IPX4
Weight| 12,0 kg| 19,8 kg| 20,8 kg| 19,5 kg
Sound power level| 90 dB| 90 dB| 90 dB| 90 dB
tank capacity| 19 l| 24 l| 24 l|  24 l

Read and understand the operating instructions before using the appliance. Abide by all the safety measures stated in the service manual. Act responsibly toward third parties.
In case of any doubts about connection and operation refer please to our customer center
Specified Conditions Of Use
The pump is designed for pumping clean water only to supply the home with water and to use it at home, in garden, courtyard and for fields. Respecting technical data and
safety precautions.
Do not use this product in any other way as stated for normal use. Not observing general regulations in force and instructions from this manual does not make the manufacturer liable for damages. The pump is not suited for long- run operation (e.g. as a circulation pump in ponds or streams). When used in this manner, its service life is  urtailed correspondingly. In these cases, then, use a time switch to secure sufficient idle periods between cycles of operation.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the grid if you do not plan on using it.
Do not use the pump for drinking water!
The pump must not be connected to the existing water-supply network as a pressureboosting device.
Never use the pump as a pool circulation pump.

Safety Instructions

WARNING!
Electric shock! There is a risk of an injury caused by electric shock!
This device is not intended for use by persons (including children) with limited physical, sensory or mental capabilities or without the necessary lack experience or knowledge unless they are supervised by a person who is responsible for their safety or were instructed by that person in how to use the device.
Children should be supervised to ensure that they do not play with the device. Always keep children and unauthorised persons out of reach of the appliance.
Operation is only allowed with a safety switch against stray current (RCD max. stray current of 30mA).
Before putting into operation, a qualified electrician must check whether electric safety measures required are in place. Any national regulations in this regard must be complied with.
Electric connection to a socket.
Do not expose the appliance to rain and do not use it in wet or moisture conditions.
It is necessary to make sure the connecting socket was not near water and humidity and the plug was protected against humidity.
Avoid installing the appliance in wet shafts (risk of short circuit, corrosion effects)!
Check the voltage. Technical data given on the type label must correspond with electric network voltage.
Only use splash proof extension cables approved for outdoor purposes.
Do not grab the feeder cable, plunge the pump, lift or carry it while it is connected to the grid!
Check the cable and/or socket for damages before the appliance putting into operation.
To avoid danger, a damaged mains supply pipe must be replaced by the manufacturer. Do not under any circumstances attempt any repair yourself.
Protect the feeder cable from excessive temperatures, oil and sharp edges.
If the pump is in operation, neither people nor animals can be present or plunged in the pumped liquid (e.g. pools, cellars, etc.).
The pump must not in any case run without fillings.
Do not leave the pump unattended while in operation in order to prevent subsequent damages caused by eventual malfunctions. Make sure to disconnect the device from the
grid if you do not plan on using it.
The temperature of the drained liquid must not exceed +35 °C.
When using the pump for domestic water supply, alwaysobserve the local regulations of water managementauthorities and the waste water drainage.
If the pump is used in ponds, wells, etc. and appropriate pumping stations, standards valid for pumps in the given country must unconditionally be observed.
Do not use pump at outside temperatures over 40°C or under 0°C
In cold weather, the pumping body motor should not bewrapped in a blanket or another piece of textile with intent toprevent the water freezing.
The user is responsible to third parties if pump (dumping stations, etc.) is used.
Requirements for operating staff
The operating staff must carefully read the Operating Instructions before using the appliance.
Qualification: Apart from the detailed instructions by a professional, no special qualification is necessary for appliance using.
Minimum age:   Persons over 16 years of age can only work on the appliance. An exception includes youngsters trained in order to reach knowledge under supervision of the trainer during occupational education.
Training:   Using the appliance only requires corresponding training by a professional or the Operating Instructions. No special training is necessary.
Emergency procedure
Conduct a first-aid procedure adequate to the injury and summon qualified medical attendance as quickly as possible. Protect the injured person from further harm and calm them down. For the sake of eventual accident, in accordance with DIN 13164, a workplace has to be fitted with a first-aid kit. It is essential to replace any used material in the first-aid kit immediately after it has been used. If you seek help, state the following pieces of information:

  1. Accident site
  2. Accident type
  3. Number of injured persons
  4. Injury type(s)

Maintenance

Before carrying out any work on the machine, disconnect the plug from the socket.
Prior to every use, visually check the machine to rule out any defects, in particular on the power cable and the plug.
The machine must not be used under any circumstances if the machine or the safety devices are damaged.
Refer all servicing to customer service. Use only original accessories and original spare parts.
Caution: Standing water may corrode (brownish colour) in the pump according to design.
At winter storing, it is necessary to make sure there is no water in the appliance as the frost could damage the appliance. Prior to transportation, it is necessary to unplug the pump from the grid! The device has to be completely emptied and stored with frost-proof protection. Adhesion of mechanical seals can be prevented if you rinse the pump with appropriate oil (for example, with vegetable oil).
Only a regularly maintained and treated appliance can serve as a satisfactory aid. Insufficient maintenance and care can lead to unforeseen accidents and injuries.

Guarantee

Guarantee claims as per guarantee card attached.
The guarantee solely covers inadequacies caused by material defect or manufacturing defect. Original payment voucher with the sales date needs to be submitted for any claim in the guarantee period.
The guarantee does not cover any unauthorised use such as appliance overloading, use of violence, damage as a  result of any unauthorised interference or caused by foreign
items. Failing to  follow the operating and assembly instructions and common wear are also not included in the guarantee..
GÜDE cannot be held responsible for damages incurred in consequence of unqualified installation or unskilled handling of the pump.
The device has to be checked on a regular basis to ensure perfect functioning.
Let us refer to the fact we do not assume any responsibility – according to standards in force – for damage eventually caused by our appliances in the belowmentioned cases:

  • Unprofessional repairs executed by unauthorised service centres;
  • Use in conflict with the designed purpose, or failure to observe the use as designed;
  • Pump overload with a continuous run;
  • Damage as a result of icing or any other fault caused by climatic influences; Identical regulations apply for accessory parts.

To prevent damage (such as flooded rooms, etc.) as a result of faulty pumpoperation (failure or fault) the owner (user) is obliged to take reasonable safety measures (alarm assembly, spare pump, etc.).
Service
Do you have any technical questions? Any claim? Do ou need any spare parts or operating instructions? We will quickly help you and without needles bureaucracy at our web pages at www.guede.com in the Servicing part. Please help us be able  to help you. In order to identify your device in case of claim we need theserial No., product No. and year of production. All this data can be found on the type label. Please enter it here forfuture reference:
Serial No.:
Art. No:
Year of production:
Symbols

| Read the Operating Instructions
---|---
| Before carrying out any work on the machine, disconnect the plug from the socket.
| Cable pulling / transport prohibited
| Staying in the transportation medium prohibited
| Warning against dangerous electric voltage
| Warning against automatic starting
| Accessory – Not included in standard equipment, available as an accessory.
| Any damaged or disposed electric or electronic devices must be delivered to appropriate collection centres.
| Protect against humidity
| This side up

Inspection and maintenance plan

Time interval Description Any other details
As needed Clean the check valve and the prefilter. Check the check valve

function.

Failures – causes – removal

Failures Causes Removal
Engine does not start No power supply. Blocked pump wheel Turn the engine

shaft with screwdriver through the fan cover (to release  friction circles sealing that may be stuck
together).
Pump does not suck| Missing, loose or blocked check valve Check valve is not in water. Pump without water Too high suction head. Air bubbles in the suction pipeline. Connections not sealed, pump sucks air, pump is not deaerated. Prefilter clogged| Fix or clean the check valve. Immerse the check valve into water. Fill the pump shell with water. Check the suction head. Check the tighten of suction pipeline. Carefully repeat connection according to the chapter „Connection“!
Clean the prefilter. 10
Thermal detector switching the pump off 4| Pump is overheated and switched off by the thermal overloading protection. No electric power supply. Impurity particles (e.g. pebbles) have
settled down in the suction hole.| Let the device getting cool!  Check power supply.
Disassemble and clean the suction hose, prevent from suction of foreign substances.
Insufficient amount of water pumped| Too high suction head. Strainer of the check valve dirty Water level quickly drops down| Check the suction head. Clean the strainer., Position the check valve lower. Clean the prefilter 10 10 Clean the pump and replace worn parts. (qualified workshop)
Reduced switching intervals| Air pressure in the receiver too low| Control air pressure. 11

SERVICE INTERNATIONAL

Germany Austria Czech Republic

Güde GmbH & Co. KG
Birkichstrasse 6
D-74549 Wolpertshausen
Tel: 0049 (0)7904 700 360
Fax: 0049 (0)7904 700 51999
www.guede.com| Güde GmbH & Co. KG
Albrechtsberg 12
AT-5270 Mauerkirchen
Tel: 0043 (0) 7724 70988
Fax: 0043 (0) 7724 70998| Güde GmbH & Co. KG
Albrechtsberg 12
AT-5270 Mauerkirchen
Tel: 0043 (0) 7724 70988
Fax: 0043 (0) 7724 70998
Slovakia| Slovenia| Serbia
---|---|---
Güde Slovakia s.r.o.
Roven 208
SK-03301 Podturen
Tel: 00421445225151
Fax: 00421445225151| TRISA d.o.o.
Begunje na Gorenjskem 147
SI-4275 Begunje na Gorenjskem
Tel: 00386 (0) 59 16 56 56
Fax: 00386 (0) 59 16 56 57| Womax Tools d.o.o.
Brace Ribnikar 55
SCG-21000 Novi Sad
Tel: 00381214722216
Fax: 00381214722217

GÜDE GmbH & Co. KG
Birkichstrasse 6
74549 Wolpertshausen
Deutschland
Tel.: +49-(0)7904/700-0
Fax.: +49-(0)7904/700-250
eMail: info@guede.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>