Product specifications

– Power supply: receiver: 90.240Vac 50 / 60H
– Range of temperature limits: 1/70.
– Display accuracy: 0.5 degrees centigrade
– Probe sensor: NTC (10k) 1,
– Temperature setting: 5/35 degrees
– Contact capacity: 5A / 250V (WW), Dimensions (mm): 130

Coupling mode

Download the Wifi app with the following icon Search Tuya or Smart Run or Smart Life.

  1. Switch on the thermostat, keep the key combination and pressed Activate the icon of the 3/IF1 distribution network
  2. The advanced password of the App is 123456
  3. For coupling with the IOS system, use with smart life is recommended.
  4. Also remember, before proceeding with pairing, make sure you work below the 2.4GH. line, setting that will be done directly from your modem router, which will be strict procedure personnel outside the responsibility of operating the device.
  5. If the connection fails on the first try, by again several times before drawing any conclusions of failure.

Instructions on the icons

Automatic mode: run the preset programmable mode
Manual mode
Holiday mode: the days and the
holiday temperature can be set to run in countdown mode.
Heating: disappears means stopping heating MS
Clock
run the programmable mode
PI execute 5 s 2 days 6 mode periods
weekly programmable; P2 perform 6 days I days 6 periods weekly programmable mode; P3 execute 7 days
6 periods weekly programmable mode
PI, P2, P3 select in the advanced setting option AB, default is
PI Status of the WIFI connection
Cloud icon

Quick Operation

| Icons| Description
---|---|---
A| | Turn-ON/OFF
B| | 1 Short press ::: to switch between automatic and manual mode
2 Power on state, long press for 3 – 5 seconds to perform the programmable setting
3 Switch-off state, long press 3-5 seconds to perform advanced settings
C| | 1 Confirm key: press with
2 Short press to set the hour
3 Holiday mode setting: OFF close this function, ON open this function
B| | 1 Decrease button
2 Long press to lock/unlock
D| | 1 Increase the key
2 Status of automatic mode, press   to enter temporary manual mode

Reset Mode (recommended for first use)
With the thermostat off, keep the key pressed for about 5 seconds until the screen with figure Al lights up, at this point press repeatedly until it reaches code A9, to conclude the procedure, swipe your finger over the icon, . and hold it for a few seconds until the Reset is activated.

Periods programming (recommended for automatic operation)
With the thermostat off, keep the button pressed for about S seconds until the screen with figure Al comes on, at this point press repeatedly until it reaches code A8, a symbol will appear on the left of the screen (this represents the weekly period where it will be possible to choose the desired option with buttons B and D

Setting programmable mode
6 period and weekly setting of the programmable mode:
5 days and 2 days (factory default), 6, 1 day, 7 days
Power-on state, long press for 3-5 seconds to enter the first period of time, then set the hour temperature, minutes, period, press “ ” and “ ” to adjust the value.
After finishing the setting, wait about 10 seconds to save the setting and then exit.
The most comfortable temperature is between 18° C and 22° C

| |
---|---|---
Wake up| Away from home| When you return
6:            00| 20°C| 8:            00| 15°C| 11:           30| 15°C
| |
When you leave| Go home| Sleep time
13:            30| 15°C| 17:            00| 15°C| 22:           00| 15°C

Advanced options
Long press shutdown state iii for 3-5 seconds to perform advanced settings.
Short press “ ” to switch and confirm. Press and for “ ” and “ ” to adjust the options.
After finishing the setting wait 5 seconds, it will save our choice and then exit.

N.o| Description| Range|

Default

---|---|---|---
| Temperature calibration| -9-03°C| 0.5°C
| h‘‘ it. hint; ditItlcotial of the integrated sensor| 05-25°C| 1°C
A3| Child lock| 0:half lock
I: full back| 0
A4| Min temp del sensor  External (frost protection)| I. MO Celsius Degrees
1. When the temperature setting is above 10 degrees centigrade, the screen display; –; cancels the frost protection| 5°C
AS| Max Temp Setting| 1-10°C| 5°C
A6| Min Temp Setting| 20-70°C| 35°C
A7| Switch off the memory| 0: Last state
1:  Electricity turns off
2:  Electricity turn on|
AS| Weekly programming| Pt: 5+2 days
P2: 6+1 days
P3: 7 days|
A9| Factory defaults| Related      |

Before wiring and installing

  1. Read these instructions carefully. Failure to comply could damage the product or cause malfunctions.
  2. Check the ratings provided in the instructions and on the product for making sure the products are suitable for your application.
  3. The installer must be a qualified technician.
    Attention disconnects the power supply before making any connections. Touching components carrying dangerous voltages can cause severe electric shock.

Warning
Disconnect the power supply before making any connections. Contact with components carrying dangerous voltages can cause electric shock.

Wiring

LEDLUX LL0253 Thermostat Wifi for Water - fig

Note on how to connect
When making the connection, it is recommended to tighten the terminal screws as required, overtightening the connection screws could cause the product to malfunction.

Video Guide to installation

https://uqr.to/Installazione_LL0253

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

LEDLUX User Manuals

Related Manuals