Home2Link ZWA019 Water Sensor 7 Pro User Guide

June 6, 2024
Home2Link

Water Sensor 7 Pro user guide (ZWA019)
Modified on: Thu, 16 Sep, 2021 at 3:32 PM

Aeotec Water Sensor 7 Pro.
Aeotec Water Sensor 7 has been crafted as a safety sensor to help detect and prevent floods and water leaks using Z-Wave Plus. It is powered by Aeotec’s Gen7 technology and S2 framework.
Familiarize yourself with your Water Sensor 7.

Package contents:

  1. Sensor Unit.
  2. Cover.
  3. Double-Sided Tape large (×2).
  4. Screws (×4).
  5.  Dowels( x4).

Important safety information.

Please read this and other device guides carefully. Failure to follow the recommendations set forth by Aeotec Limited may be dangerous or cause a violation of the law. The manufacturer, importer, distributor, and/or reseller will not be held responsible for any loss or damage resulting from not following any instructions in this guide or in other materials.
Keep product and batteries away from open flames and extreme heat. Avoid direct sunlight or heat exposure. Always remove all batteries from products that are being stored and not used. Batteries may damage the appliance if they leak. Do not use rechargeable batteries. Ensure correct polarity when inserting the batteries. Improper battery use may damage the product.
Water Sensor 7 is intended for indoor use in dry locations only. Do not use in damp, moist, and/or wet locations.
It contains small parts; keep away from children.

Quick Start

Installation of Water Sensor 7 Pro.

  • Open the cover by pressing the clip on the side and pulling the cover upwards
  • Insert a fresh 1 * 1/2 AA battery, but pay attention to the polarity

Install your Water Sensor 7 Pro.

The Water Sensor 7 should be placed wherever you want to monitor for possible flooding or leaks. When placing the Water Sensor 7, consider the direction in which a flood or leak may flow and where it may occur. The contacts of the Water Sensor 7 probe will detect the liquid, so the probe must be placed so that any flood or leak will come into contact with it. When the probe contacts come into contact with a liquid, the Water Sensor 7 sends a leak warning to your Z-Wave Gateway. Make sure that both contacts are capable of detecting leaks or flooding.
Add your Water Sensor 7 to the Z-Wave network.
Dedicated hub setup guides :

  • Aeotec AutoPilot
  • Aeotec Smart Home Hub / SmartThings
  •  Home Assistant / Z-WaveJS
  • Habitat
  • Vera UI7

SmartStart Inclusion.
You can use this method of inclusion only if your Z-Wave gateway/controller/hub supports SmartStart.

  1. Open up your Z-Wave gateway/controller/app.
  2. Select SmartStart inclusion.
  3. Scan the QR code located on the Water Sensor 7.
  4. Within 10 minutes after powering your Water Sensor 7, it will automatically get included in your Z-Wave gateway/controller/hub.

Classic Inclusion

  1. Set your Z-Wave controller into pairing mode.
  2. Triple-click the tamper switch on Water Sensor 7 – this begins to blink five times
  3. After completion of the inclusion, the LED will illuminate green for 3 seconds.
  4. If you pair with S2 encryption/security, enter the first 5 digits of the DSK into your controller/gateway/hub interface when requested.
  5. Close the cover

Water leak
Once installed, this sensor will report wet or dry via Notification Command Class when this device is wet or removed from the water.

  •  Notification Report
  • Type: Unknown (0x05)
  •  Value: Wet (0x02) or Dry (0x00)

Tamper
A tamper alarm will be sent if the cover is removed.

  • Notification Report
  • Type: Tamper Removed (0x07)
  • Value: 0x03

Temperature
This sensor will report occasionally on its own as an unsolicited Multilevel Sensor Report either by a timed interval (Parameter 18) or by the change in value (Parameter 16).
Multilevel Sensor Report

Humidity

This sensor will report occasionally on its own as an unsolicited Multilevel Sensor Report either by a timed interval (Parameter 18) or by the change in value (Parameter 17).

Multilevel Sensor Report

LED indicator.

Function Description LED Indicator
Device Not in Network Blinks red for 5 seconds (1-sec duty cycle) when

the battery is inserted and the sensor is not in-network
Include/Exclude/Learn Mode| Illuminate green for 3 seconds when Inclusion / Exclusion /Configuration is successful. Illuminate red for 3 seconds when Inclusion / Exclusion / Configuration is unsuccessful (upon a timeout of 30 seconds). .
Local Reset| When the device is locally reset to Factory Default LED blinks red (1second duty cycle) for 5 seconds.
LowBatt| When the operation button is Short Pressed the LED blinks red three-time (1 sec duty cycle)
Tampering| If either Tamper Switch 1 or 2 is activated the device blinks redone time with ½ second duty cycle if within range of Controller. The device blinks red three times with ½ second duty cycle if out of range of Controller
Water protection| When the operation button is Short Pressed the LED illuminates three seconds in case of Water Leakage detected and Green if no Leakage is detected.

Button Function.

Push Type Function Description
Long Press 5s Pending reset LEDs start indication Waiting for Rese
Long Press 10s Reset Initiates Device Reset Locally.
Short Press Tamper Sends Wake Up notification.
3 Times Short Press Sequence See Learn Mode.

Advanced Functions.

Communication test.

This utilizes the Power Level command class to determine the health between the Water Sensor 7 and your Z-Wave gateway. This will tell you if the Water Sensor 7 has a healthy connection to your system and is a great method of debugging connectivity issues.

  1. Set Parameter #4 to value #1
  2. Double click the Tamper Switch.
  3. Result:
    • Green LED blinks once – success
    • Red LED blinks 3x times – failure

Firmware-Update over the Air.

This device is capable of receiving a new firmware ‘over the air’. The update function needs to be supported by the central controller. Once the controller starts the update process, perform the
following action to confirm the firmware update:

  1. Wake Up the device by removing the cover.
  2. Hit the tamper switch once.

Send a wake-up notification.
In order to send your sensors new configuration commands from your Z-Wave controller or gateway, it will need to be woken up.

  1. Wake Up the device by removing the cover.
  2. Hit the tamper switch once.
    Note: Water Sensor 7 remains awake until the housing is closed again

Remove your Water Sensor 7 from Z-Wave network.

Your sensor can be removed from your Z-Wave network at any time. You’ll need to use your Z-Wave network’s main controller/gateway. To do this, please refer to the part of your gateways respective manual that tells you how to remove devices from your network.

  1. Set your Z-Wave controller into unpair mode.
  2. Triple-click the tamper switch on Water Sensor 7 within 1.5 seconds – this will cause the LED to blink five times.
  3. After a successful exclusion, it will light up its LED for 2 seconds then deactivate.

Reset your Water Sensor 7.

This device also allows being reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

To manually factory reset:

  1.  Remove the cover of Water Sensor 7
  2.  Press and hold the tamper switch for 5 seconds until the red LED blinks.
  3. Release the tamper switch
  4. Immediately press and hold the tamper switch for 5 seconds until the red LED blinks.

Association Groups
Group Association allows Water Sensor to directly communicate with other Z-Wave devices directly without the need for the Z-Wave Controller to act as an in-between controller. This using this function will help with communication efficiency and limit the amount of time it takes to control a device.

Group
Number| Maximum
Nodes
| Description
---|---|---
1| 5| Lifeline
2| 5| Control devices when water leakage is detected
3| 5| Sends out alarm message when water leakage is detected
4| 5| Sends alarm messages when tamper is tripped

Parameter setting.

3. Visual LED indications
Parameter: 3
Size: 1 Byte
Default Value: 7
Description:
This parameter defines when the red LED will indicate events. Disabling all indications may extend battery life.
(values 1 + 2 + 4 summarized)
0 – No indications
1 – Water Leakage Status Change
2 – Wake Up (1 x click)
4 – Device tampering| 6. Command Sent to Devices of Association Group 2
Parameter: 6
Size: 1 Byte
Default Value: 255
Description:
This parameter defines which commands are sent to 2nd Association Group
0 – On
1 – Off
2 – On and Off| 9. Time Delay of On command frame
Parameter: 9
Size: 2 Byte
Default Value: 0
Description:
On command is sent after a delay defined in this parameter.
0 – 32400 – Seconds| 1 2. Reporting tamper alarm cancellation
Parameter: 12
Size: 1 Byte
Default Value: 1
Description:
This parameter defines if the alarm cancellation event is reported.
0 – do not send report
1 – send report
---|---|---|---
4. Range test after double click
Parameter: 4
Size: 1 Byte
Default Value: 0
Description:
Allows enabling the activation of a Z-Wave range test with double-clicking the tamper switch.
0 – disabled
1 – enabled| 7. BASIC command value sent to 2nd Association Group on On event
Parameter: 7
Size: 1 Byte
Default Value: 255
Description:
This is the BASIC command value sent in case of On even
0 – 99 – Value
255 – On| 10. Time delay of Off command frame
Parameter: 10
Size: 2 Byte
Default Value: 0
Description:
Off command is sent after a delay defined in this parameter0 – 32400 – Seconds| 1 6. Minimum temperature change to report.
Parameter: 16
Size: 1 Byte
Default Value: 20
Description:
This value defines the minimum change of temperature to cause an unsolicited report of
temperature to the central controller using Lifeline. If the value is set to 0, there will be no reports
sent to the controller, when the temperature changes. However, periodic reports, managed by
configuration parameter 18, may still be active.
0 – disabled
1-100 – 0,1 degree step
5. 2nd Association Group Trigger
Parameter: 5
Size: 1 Byte
Default Value: 0
Description:
This parameter defines the status of the water leakage that causes sending a BASIC command to
all devices of Association Group 2.
0 – Switch after Water Leakage Start and Stop
1 – Switch after Water Leakage Start
2 – Switch after Water Leakage Stop| 8. BASIC command value sent to 2nd Association Group on Off event
Parameter: 8
Size: 1 Byte
Default Value: 0
Description:
This is the BASIC command value sent in case of Off event.
0 – 99 – Value
255 – On| 11. Delay of tamper alarm cancellation.
Parameter: 11
Size: 2 Byte
Default Value: 0
Description:
Time a tamper alarm is delayed.
0 – 32400 – Seconds| 17. Minimum humidity change to report.
Parameter: 17
Size: 1 Byte
Default Value: 5
Description:
This value defines the minimum change of humidity to cause an unsolicited report of humidity to
the central controller using Lifeline. If the value is set to 0, there will be no reports sent to the
controller, when the humidity changes. However, periodic
reports, managed by configuration parameter 18, may still be active.
0 – disabled
1-20 – value in %
18. Periodic Reports.
Parameter: 18
Size: 2 Byte
Default Value: 43200
Description:
This parameter defines the time interval to send an unsolicited report. If the value is set to 0, there
will be no periodic reports sent to the controller. However, reports on temperature/humidity
changes, managed by configuration parameters 16 and 17, may still be active.
0 – disabled
900-65535 – value in seconds| 6 4. Temperature Scale
Parameter: 64
Size: 1 Byte
Default Value: 1
Description:
This parameter sets the temperature scale.1 – Celsius
2 – Fahrenheit| 255. Reset Parameter
Parameter: 255
Size: 4 Byte
Default Value: 0
Description:
This parameter helps reset configuration parameters and the device to factory defaults
1- Reset all Parameter settings to their default settings.
1431655765 – (0x55555555) Completely factory reset sensor and send device reset locally
notification
---|---|---

Water Sensor 7 technical specifications.
Modified on: Mon, 11 Oct, 2021 at 3:51 PM

This page lists the technical specifications for Water Sensor 7 and forms part of the larger Water Sensor 7 Basic user guide and Water Sensor Pro user guide.

Name: Water Sensor 7 Basic
Model number:
US: ZWA018-A/ZWA043-A
AU: ZWA018-B/ZWA043-B
EU: ZWA018-C/ZWA043-C
Sensors:
Water Sensor
Tamper
Product Weight: 42.5 g
Total Package Weight: 83 g
Product Dimensions: 70 x 13 x 20 mm
Wire length: 1.1 m
Package Dimensions: 72 x 120 x 30 mm
UPC/EAN:
US: 810667025328
EU: 1220000016705| Technical Specifications:
Z-Wave Hardware: ZGM130S
Z-Wave Version: 7.12 or later
Smart Start: Yes
Repeater: No
Beaming Capable: No
Security Supported:
S2 Unauthenticated
S2 Authenticated
Operating distance:
More than 50 meters indoors / More than 164 feet indoors.
Up to 150 meters outdoors / Up to 492 feet outdoors.
Operating temperature: 32°F to 113°F / 0°C to 45°C.
Storage temperature: -22°F to 158°F / -30°C to +70°C
Relative humidity: 10% to 95%.
Humidity range: 0 to 80% RH +- 3%
Temperature range: -10 to 65°C (+- 1°C) / 14 to 149°F (+- 1.8°F)
Battery Lifetime: up to 3 Years
Battery type: 1/2 AA ER14250 3.6V
Max Current Consumption: 5mW
---|---
Name: Water Sensor 7 Pro
Model number:
US: ZWA019-A/ZWA044-A
AU: ZWA019-B/ZWA044-B
EU: ZWA019-C/ZWA044-C
Sensors:
Water Sensor
Tamper
Temperature Sensor
Humidity
Product Weight: 42 g
Total Package Weight: 82g
Product Dimensions: 70 x 13 x 20 mm
Wire length: 1.1 m
Package Dimensions: 72 x 120 x 32 mm
UPC/EAN:
US: 810667025335
EU: 1220000016729| Waterproof and dust rating: IP20 under IEC 60529
List of supported Command Classes
Association
Association Grp Info
Battery
Configuration
Device Reset Locally
Firmware Update Md
Indicator
Manufacturer Specific
Multi-Channel Association
(Pro only) Sensor Multilevel
Notification
Powerlevel
Security 2
Supervision
Transport Service
Version
Wake Up
Zwaveplus Info

www.home2link.nl
info@home2link.nl
Tel: 085-029 05 078
Home2Link B.V.
Tingietersweg 107
2031 ER HAARLEM

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals