Lucci LEDlux 240727, 240728 Alert Installation Guide
- June 4, 2024
- LUCCi LEDlux
Table of Contents
Installation Instructions
ALERT
SKU# 240727, 240728
Rated Voltage 220-240V~ 50Hz
240727, 240728 Alert
Thank you for purchasing this quality Lucci product. To ensure correct function and safety, please read and follow all instructions carefully before assembly, installation, and use. Please keep instructions for future reference.
Warranty
- This light fitting is covered by a 3-year warranty. The warranty is from the date of purchase, not the date of installation.
- If the fitting is not installed by a licensed electrician the warranty will be void.
- Please retain the proof of purchase and evidence of installation by a licensed electrician.
- The warranty will be void if there is any damage due to improper usage or modification to the fitting.
- Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void the warranty.
- This fitting is not suitable for use with dimmer switches. The warranty will be void if the fitting is used on the same circuit which has a dimmer switch.
Installation requirements
-
Must be installed by a licensed electrician.
-
All wiring and installation of the light fitting must adhere to local and national wiring rules. eg. AS/NZS 3000:2007/Amendment 2:2012 Electrical installations.
-
Select a suitable location for installation;
– This product is suitable for indoor and outdoor use.
– The mounting point must support 2 times the weight of the fitting.
– This fitting is protected against water penetration to IP44 standards, which is splashing in every direction.
– This fitting must not be mounted on a surface that can be subject to vibrations.
– Take note of the directional marking on the fitting before installation. -
Take care not to pull any electrical wires during unpacking as this may damage the connection.
-
Lay out all the components on a smooth surface and make sure there are no components missing before assembling. If parts are missing, return the complete product to the place of purchase for inspection or replacement.
-
Check whether the fitting has been damaged during transport. Do not operate/install any product which appears damaged in any way. Return the complete product to the place of purchase for inspection, repair, or replacement.
-
Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.
PIR sensor information
PIR (PASSIVE INFRARED) SENSOR:
The fitting has a PIR (Passive Infra Red) sensing device which continuously
scans the operating zone and immediately switches the light on when it detects
movement in that area. Whenever movement is detected within the range of the
sensor, the light will switch on automatically to illuminate the area. While
there is a movement within the sensor range, the light will remain on.
SENSOR LOCATION & INFORMATION:
To find a suitable location for installation, please take into consideration
the following points:
- The ideal mounting height for the fitting is between 1.8m to 2.5m above the detection area (figure 1).
- The detection area is approximately 8 meters away at an angle of 100° wide. This may vary depending on the mounting height and location.
- The detection area may also alter at different temperatures. PIR sensors are more sensitive in cold weather than in warm weather.
- The sensor has better sensitivity with movement across the detection area (figure 2).
- The sensor has reduced sensitivity with movement towards and away from the detection area (figure 3).
- If movement is made walking directly towards or away from the sensor and not across, the apparent detection range will be substantially reduced.
- To avoid false triggering, the sensor should be directed away from potential heat sources, such as barbecues, air conditioners, air vents, etc.
- Also avoid areas with electromagnetic disturbance, outside lighting, moving cars, trees or pets, etc.
- Avoid installing the fitting in close proximity or on the same circuit as any fluorescent light fittings or ceiling fans. RFI (Radio Frequency Interference) may cause the fitting to switch on unintentionally.
- Do not aim the sensor towards reflective surfaces, such as smooth white walls, swimming pools, etc.
- To avoid damage to the sensor, do not aim the sensor toward the sun.
- It is recommended that the fitting is installed on its own switch and does not interconnect with other lights on the same switch as it may cause false triggering.
Installation directions
- Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work.
- Remove the mounting bracket from the body of the fitting by loosening the screw using an Allen key.
- Use the mounting bracket as a template to mark the screw positions on the wall. Drill holes into the wall and push the plastic anchors into the holes.
- Loosen the cord anchorage near the terminal block.
- Push the main supply wire through the cord entry point on the mounting bracket. Depending on the installation location, additional silicon may need to be added to maintain the IP44 rating of the fitting.
- Connect the main supply wire to the terminal block provided. Ensure that the wires are secure and no bare wires are exposed.
Mains Supply Wire| Wiring Label
---|---
Earth – Yellow/Green| Yellow/Green
Neutral – Blue or Black| N (Neutral)
Live – Brown or Red| L (Live) - Install the mounting bracket onto the wall by using appropriately sized mounting screws, plastic washers, and anchors.
- Ensure the screws, plastic washers and anchors used are suitable for the mounting surface.
- Place the main supply wire in the cord anchorage system and secure it by tightening the screws again.
- Install the fitting back onto the mounting bracket.
- Tighten the two screws using an Allen key. Adjust the LED heads and PIR sensor to the desired position.
- Switch the power to the circuit back ON only after all electrical work has been fully completed and the fitting is fully assembled and ready to use for the first time.
SENSOR SETTINGS:
DURATION TIME: The length of time the light will remain switched on after
activation can be adjusted from 10secs ±5 to 4mins ±1. Rotating the time from
(+) to (-) will reduce the duration time.
NOTE: Once the light has been triggered by the PIR sensor, any subsequent
detection will start the timed period again from the beginning, the light will
remain on until there is no movement detected.
ADJUSTING THE SENSITIVITY: The sensitivity means the maximum distance at
which PIR Sensor can be triggered by the moving body. Turning the SENS knob
from + to – will decrease the sensitivity. LUX LEVEL: The lux control
module has a built-in sensing device (photocell) that detects daylight and
darkness. The ( ) position means that the fitting will work both day and
night. The ( ) position will only work at night.
NOTE: If you want to test the detection area of the PIR sensor, please
wait for the ambient light level to be below 20 lux.
SENSOR TESTING:
- Put the LUX control knob in the light ( ) position and the TIME control knob to a minimum (-). Turn the wall switch on and the light will turn on and remain on for about 50 seconds for the “warm-up” mode. After this initial “warm up” mode the light will turn off and the fitting will be in AUTO MODE.
- Direct the sensor toward the desired area to be scanned by twisting the sensor left and right.
- Have someone walk across the center of the area to be scanned and slowly adjust the angle of the sensor until the fitting can sense the moving person and causes the light to switch on.
- Adjust the TIME control knob to the desired length of time for the fitting to remain on.
- Adjust the LUX control knob to achieve the ideal ambient light for the fitting to switch “on”.
For the fitting to switch ‘on’ when the ambient light is darker, switch the LUX control knob from ( ) to ( ).
For the fitting to switch ‘on’ when the ambient light is brighter, switch the LUX control knob from ( ) to ( ).
You may need to make further adjustments to achieve your ideal light-level setting.
MANUAL MODE: (Sensor Override Function)
Manual mode is used when you want the LED lights to be constantly on. The PIR
sensor will be disabled and not affected by the duration time and lux level
settings. The maximum duration for manual mode is 8 hours.
-
During normal use, the wall switch is in the ON position and the fitting is in AUTO MODE with the PIR sensor detecting any movement and the LED lights will switch on and off accordingly.
-
To switch into MANUAL MODE, turn the wall switch off and on twice within three seconds.
Wall switch action: OFF → ON → OFF → ON.
Wait for 3 seconds and the LED lights will turn on and the fitting will be in MANUAL MODE.
NOTE: If the wall switch action is done only once or more than twice, the fitting will not enter into MANUAL MODE. -
To change back to AUTO MODE, turn the wall switch off and on twice within three seconds.
Wall switch action: OFF → ON → OFF → ON.
NOTE : During MANUAL MODE or AUTO MODE, switching off the wall switch
for about 15 seconds will reset the sensor mode.
Turn the wall switch on again and the PIR sensor will enter into the “warm-
up” mode and the LED lights will remain on for about 50 seconds. After this,
the LED lights will turn off and the fitting will be in AUTO MODE.
Troubleshooting
PROBLEM | POSSIBLE CAUSE | SUGGESTED SOLUTION |
---|
The light does not switch on when there is movement in the detection
area.| No mains voltage.| Check all connections, fuses, and switches.
Nearby lighting is too bright.| Redirect the sensor or relocate the unit.
Controls are set incorrectly.| Readjust the sensor angle or control knob.
Light switches on for no apparent reason (false trigger)| Heat sources
such as air-con, Vents, heater flues, barbecues, another outside lighting, and
moving cars are activating sensors.| ** Adjust the direction of the sensor
head away from these sources.
Animals, birds, possums, pets, etc.| Redirecting the sensor head may help.
Reflection from a swimming pool or another reflective surface.| Redirect
sensor.
The light remains on.| Continuously false triggered.| Redirecting the
sensor head may help.
Time control is set too long.| Reduce time.
Light switches on during daylight hours.| The LUX control knob is set to
the daylight position.| Turn the LUX control knob to the desired light level
setting.
When setting controls in daylight the detection distance becomes
shorter.**| Interference by sunlight.| Re-test at night.
Safety Tips
- Always ensure the power is OFF and the fitting has cooled down before performing any maintenance, cleaning, or making any adjustments to the fitting.
- To avoid injury or damage to the fitting, ensure that power leads and screws are secure before connecting the power.
- Select a suitable location away from liquids and hazards.
- Ensure that the fitting does not come in contact with corrosive chemicals, etc.
- To clean, wipe with a damp clean cloth. Never soak the fitting with water.
Specifications
SKU # | 240727 | 240728 |
---|---|---|
Colour | Black | White |
Rated Voltage | 220-240V~ 50Hz | |
Rated Wattage | 12W | |
LED | 4000K, 600lm | |
Weight | 0.61kg | |
Dimensions | E:190mm W:210mm H:340mm | |
IP Rating | IP44 |