IMPORTANT SAFETY NOTICE
Please Read this manual before operating
Caution: Please read this manual carefully before operating Damage caused by misuse is not covered by the warranty
Introduction
Thank you for choosing THE FRACTAL-250 laser as part of your effects lighting
equipment.
This product has been designed to project multi-point and pinwheel geometric
patterns in 3 colors across a wide area. Please read and retain this manual to
achieve the best results from your purchase and avoid damage through misuse.
CAUTION
- Please read this manual fully before installing or operating this product as it contains important safety information relating to its installation and operation.
- This Class 3B laser product emits hazardous levels of optical radiation and will cause injury to the eyes if viewed directly.
- This product is not suitable for projection directly to audiences or other personnel.
- This product must not be used for any form of audience scanning application and is for professional use only.
Important information
This product is a Class 3B laser and should only be installed and used by
personnel who are trained in the management of laser radiation and are able to
operate in accordance with the guidance given by the Health and Safety
Executive (HSE) in HS(G)95: “The Radiation Safety of Lasers used for Display
purposes”.
Copies of this guide can be downloaded from the HSE website:
www.hse.gov.uk/pubns/priced/hsg95.pdf
This product contains no user-serviceable parts. Under no circumstances should
any attempt be made by the user to dismantle or modify it in any way.
Installation instructions
This product must be securely mounted with adequate fixings to hold the weight. If mounted at height, use a safety wire attached to a secondary fixing point. Position the aperture so that its emission is always directed away from people and objects that are able to reflect the emission towards people. In this regard, the separation distances of 3 meters vertically and 2.5 meters horizontally, cited in HS(G)95 and shown below must be observed.
Unpacking
Please check the contents to ensure that the product has been received in good
condition.
Fractal-250 laser
Mounting bracket and screws
IEC power lead(s)
Safety lock keys
If you find any accessories is missing or the product has arrived with any
problems, please contact your retailer at once.
This product contains no user-serviceable parts so make no attempt to try to
fix or modify this item yourself as this will invalidate the warranty. We
recommend you keep the original package and proof of purchase for any possible
replacement or returned demand.
Setting up
- Unpack the laser ensuring all packaging and tape is removed.
- Always test the laser before fixing in a permanent location.
- Connect the IEC mains plug and switch the rear power switch on.
- Insert the safety key and turn to a quarter turn clockwise. At this point ensure that no one is exposed to laser radiation.
- Select which mode you want to operate the laser in.
- Leave the laser to run for 10 minutes before installing in its location.
Vertical bird’s eye view
Vertical cross-sectional view
Connecting to mains, earth wire (ground) must be connected.
Use the supplied IEC lead to connect to the main power supply as follows:
Wire | Connection | International symbol |
---|---|---|
Brown | Live | L |
Blue | Neutral | N |
Yellow /Cyan | Earth |
For your safety, please kindly pay attention to all of the warnings below:
- Always plug in the power plug last and disconnect from the mains when the device is not in use or before cleaning.
- Do not install and operate the device in rain or extreme heat, moisture or dusty environments.
- This device is for indoor use only and in a dry environment.
- Do not switch on immediately. Wait until the unit reaches room temperature.
- Do not shake the device and avoid brute force when installing or operating.
- Do not use the device during thunderstorms and please disconnect the power.
- Do not use solvents or aggressive detergents to clean the device. Use a soft and clean cloth.
- Do not modify the device or the IEC power cord without authorization.
- Do not stare into the aperture. This product emits hazardous levels of optical radiation and will cause serious injury to the eyes if viewed at close range.
- This product should be securely mounted so that its output emission is always directed away from people and at objects that are able to reflect emission towards people. In this regard, the separation distances cited in HS(G)95 should be observed.
- The symbol determines the minimum distance from lighted objects. The minimum distance between light output and the illuminated surface must be more than 0.5m.
Replacing the fuse
First disconnect from the mains power supply then removes the fuse holder
part of the IEC Socket to reveal the fuse. Replace with the correct fuse
rating as stated on the product or in the user manual. Then lock the fuse
holder cover back into place.
General maintenance
Be sure to power off the fixture before conducting maintenance.
To maintain optimum performance and minimize wear, fixtures should be cleaned
frequently.
Usage and environment are contributing factors in determining frequency. As a
general rule, fixtures should be cleaned at least twice a month. Dust build-up
reduces light output & performance as well as overheating. This can lead to
reduced life and increased mechanical wear.
Unplug the fixture from power. Use a vacuum or air compressor and a soft brush
to remove dust collected on external vents and internal components.
Keep the laser aperture clear of obstructions and to not cover the cooling fan
vent or other parts of the housing.
Front panel
1. Sound activation microphone | 3. Power LED |
---|---|
2. Microphone signal LED | 4. Laser aperture |
Rear Panel
5. Power on/off switch | 8. Mic. sensitivity control |
---|---|
6. Auto/sound active switch | 9. Safety lock |
7. IEC mains inlet & fuse holder | 10. Cooling fan vent |
Positioning
Following the aforementioned safety guidelines, select the preferred
projection area.
The Fractal-250 laser uses red, green, and blue color lasers to project multi-
point and spiral images, which may be best displayed on a light-colored wall
or surface. Using fog or haze machines can also help to develop beamlines
between the laser and projection area.
Operation
Connect power to the IEC mains inlet (7) using the power lead provided or
equivalent.
Ensure that the aperture (4) is directed away from any line of sight and
switch on power (5) Turn the key switch on the safety lock (9) to the “on”
position.
The Power LED on the front panel will illuminate.
In AUTO mode, the Fractal-250 laser produces all the pre-programmed patterns
in sequence.
Switching to SOUND mode (6) makes the sequence governed by the front
microphone (1) The sensitivity of this microphone is controlled by the
Sensitivity dial on the rear panel (8) To check if the microphone sensitivity
is adjusted correctly, check the Mic. LED located on the front panel (2) to
see how it reacts to sound. This represents the sound trigger that controls
the effect sequence.
When not in use, power down the Fractal-250 laser and remove the IEC if not
used for long periods. For security, turn the key in the safety lock to the
“off” position and remove the key to avoid use by unauthorized persons.
Specifications
Power supply | 100-250Vac, 50/60Hz (IEC) |
---|---|
Fuse rating | 2A |
Laser class | 3R |
Red laser power | 180mW (650nm) |
Green laser power | 60mW (532nm) |
Blue laser power | 100mW (450nm) |
Patterns | 8 different geometric shapes |
Dimensions | 190 x 185 x 71mm |
Weight | 990g |
Laser & LED safety standard | BSEN60825-1 2007 |
Troubleshooting
No power or output | Check that mains power is connected correctly |
---|
Check that the power indicator is on and the mains fuse is OK
If the fuse continually blows, refer to qualified service personnel
Power OK but no output| Check that laser aperture is not covered
Ensure safety key switch is set to “on”
If the ambient temperature is low, wait up to 30 mins for warm-up
Check if set to sound-activated without any sound to trigger
Laser output very dim| If the ambient temperature is low, wait up to 30 mins
for warm-up
If necessary, carefully clean the scanner mirror with alcohol
Reduce the distance to the projected surface
Laser on but no movement| Check if set to sound-activated without any sound to
trigger
Check if in DMX mode without motion command from DMX
Adjust DMX controls manually to check motion commands
Important: This product conformed to Laser & LED Safety standard BSEN60825-1 2007 incorporating corrigendum 2008
This product is classed as Electrical or Electronic equipment and should not be disposed of with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright® 2021 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
Errors and omissions excepted.
AVSL (Europe) Ltd, Unit 3D North Point House,
Taylor Road, Trafford Park, Manchester. M41 7)Q.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>