CACHFIRES BIO-10-008 Wall-Mounted Bioethanol Fireplace Instruction Manual
- June 9, 2024
- CACHFIRES
Table of Contents
- CACHFIRES BIO-10-008 Wall-Mounted Bioethanol Fireplace Instruction Manual
- WALL-MOUNTED BIOETHANOL FIREPLACE INSTALLATION & CLEARANCE
- WARNINGS
- Fireplace
- WARNING: Ensure that your fireplace is positioned away from flammable
- Assembly and Mounting
- Models: Nevada
- Decoration
- Operate the bioethanol burner according to the bioethanol burner user
- Assembly and Mounting
- Decoration
- Use and operation
- CACH FIres
- Read More About This Manual & Download PDF:
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
CACHFIRES BIO-10-008 Wall-Mounted Bioethanol Fireplace Instruction Manual
WALL-MOUNTED BIOETHANOL FIREPLACE INSTALLATION & CLEARANCE
Please read the instructions in this manual before operating any of the CACH Fires bioethanol fireplaces mentioned in this manual.
WARNINGS
Fireplace
Clearance __ Read and understand these instructions completely before
using your CACH Fires bioethanol fireplace.
These bioethanol fireplaces are suitable for indoor use only.
Exposing the fireplace to rain, snow or similar weather conditions will
drastically decrease the lifespan of the fireplace and will make it rust and
corrode.
Before use ensure that the model is positioned in accordance with the
compulsory minimum clearances outlined below and that the minimum room size is
met:
Nebraska | 40m3 (1415ft3) |
---|---|
Nevada | 45m3 (1590ft3) |
WARNING: Ensure that your fireplace is positioned away from flammable
materials and other sources of ignition at all times. Pay very close attention
to items that may move as a result of wind and drafts. For example plants/
curtains/paper and the like.
The bioethanol burner within the fireplace must never come into direct
contact with flammable materials.
The recommended installation height is 800-1200mm [35.4 – 47.2in] from the
floor – but varies depending on placement of installation. Minimum floor
clerance is 200mm [7.8in].
Side clearance to fixed and stable furniture must remain a minimum of 600mm
[23.6in].
Overhead clearance to flammable and heat-sensitive items must be a minimum of
1000mm [47.2in] for “ closed top” fireplaces and 1500mm [59in] for “ open
top ”.
The fireplaces can be mounted on all types of walls, as long as it can carry
the weight of the fireplace.
Assembly and Mounting
Models: Nevada
-
Remove the fireplace and all parts from the
-
Attach bioethanol burner mounting plate with 4 screws, from the inside of the burner
-
Attach the 4 glass spacing rods with the included screws from behind the back
Screw the glass panel onto the spacers with the 4 included screws. Place one plastic washer on each side of the glass for every screw. -
Place the bioethanol burner into the cutout with the flame opening facing
-
Fasten the mounting brackets to the wall, as shown on the When the bracket is securely fastened, the fireplace can be hung on the mounting bracket.
Decoration
Bioethanol fireplace decoration is not recommended to use in this bioethanol fireplace.
Use and operation
Operate the bioethanol burner according to the bioethanol burner user
manual included with the fireplace.
Assembly and Mounting
Models: Nebraska
-
Remove the fireplace and all parts from the
-
Attach the glass screen with the two included Place one plastic washer on each side of the glass for every screw.
-
Fasten the mounting brackets to the wall, as shown on the When the bracket is securely fastened, the fireplace can be hung on the mounting bracket.
-
Place the bioethanol burner into the cutout with the flame opening facing
Decoration
Bioethanol fireplace decoration like ceramic wood and stones are not recommended to use in this bioethanol fireplace.
Use and operation
**** Operate the bioethanol burner according to the bioethanol burner user manual included with the fireplace.
CACH FIres
EU Tel: +45 60 66 96 03
UK Tel: +44 1224 011575
Email: info@cachfires.com