FK Irons B08D6S2GYB Spektra Flux Cartridge Machine User Manual
- June 6, 2024
- FK Irons
Table of Contents
- SAFETY NOTICE
- TECHNICAL DATA
- MACHINE OVERVIEW
- THE GRIP
- THE POWERBOLT
- DETACHING THE POWERBOLT
- USB-C CONNECTION
- CONNECTING YOUR MACHINE
- ADJUSTING NEEDLE DEPTH
- eGIVE
- CHANGING eGIVE
- ADDITIONAL INFORMATION
- ADDITIONAL INFORMATION
- TROUBLESHOOTING
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USER MANUAL
2021
SAFETY NOTICE
|
CLASS III SYMBOL
A Class III appliance is designed to be supplied from a separated/safety extra-low voltage (SELV) power source. The voltage from a SELV supply is low enough that under normal conditions a person can safely come into contact with it, without risk of electrical shock. The extra safety features built into Class I and Class II appliances are, therefore, not required. For medical devices, compliance with Class III is not considered sufficient protection, and more stringent regulations apply to such equipment.
---|---
TECHNICAL DATA
Operating Voltage: | 5 – 12 V DC |
---|---|
Current: | 1:00 AM |
Stitch Frequency: | 25 -160 Hz |
Stroke: | 4 mm |
Connection: | USB-C |
Drive: | Brushless 9-watt motor |
Operating Mode: | Continuous operation |
Ambient Temperature: | +10 to +35° C |
Relative Humidity: | 30 to 75% |
Dimensions (Ø X L): | 35 x 125 mm |
Weight: | Approx. 180 g |
BARRIER PROTECTING YOUR MACHINE
Although the grip is autoclavable, we strongly suggest the use of barrier
products to protect your machine. For a visual demonstration of many barrier
protection methods, please visit FK Irons’ YouTube channel.
This device is only for use by trained tattoo artists and not for use by
children or persons of reduced physical, sensory or mental capabilities.
MACHINE OVERVIEW
THE SPEKTRA FLUX
Unleash your Power
The first wireless pen-style machine features detachable batteries, complete
Bluetooth connectivity, and a whole new sense of freedom.
THE GRIP
THE GRIP
The Flux grip allows artists ratcheting control over needle depth. The
standard Grip has a diameter of 33 mm. Other grip options will be available
soon. The Grip is crafted from a solid rod of 6061 T6 aircraft-grade aluminum.
This polished and anodized grip is safe to be sterilized under steam, in an
autoclave or wiped down with cold sanitation solutions.
THE BODY
The Body is the core of the machine. Constructed from a solid rod of 6061 T6
aircraft-grade aluminum, this module should be sanitized by wiping it with
cold sterilization solutions only. Caution: Avoid getting fluids into the
housing
THE POWERBOLT
THE POWERBOLT
LED indicator:
Solid Color = Whole Value
Blinking Color = Half Increment
Ex. Solid green indicates 10V
Flashing green indicates 10.5V
Battery level checks: Press and
hold the power button until white. A blinking colored light indicates the
remaining charge.
Note: LED flashes while battery charges. Once < 15% is reached, the red light will blink alternately with voltage.
Working with modes: Modes work by pressing and releasing the power button.
Bluetooth – Hold the power button until a blue light appears and immediately
release the power button. A blue blinking light indicates pairing mode is
available for 60 seconds. To deactivate
Bluetooth, hold the power button, and release when the yellow light
flashes.
Travel Mode (hard shutoff) – Press and hold the power button until the
red light flashes. Use this mode to avoid unnecessary discharge and/or comply
with travel laws. To reactivate, connect/disconnect to a USB-C port.
Reset (factory settings) – Should you experience abnormal behavior, hold the
power button and the voltage down button at the same time, then quickly
release.
Device reset:
DETACHING THE POWERBOLT
DETACHING THE POWERBOLT
To detach your PowerBolt, ensure you have a firm grip on the Body and Grip.
Turn the PowerBolt counterclockwise and pull it apart. To attach the
PowerBolt, push in while twisting clockwise. Ensure the lock mechanism moves
freely. PowerBolt must be flush to ensure power leads align correctly. Avoid
contact with the PowerBolt leads while recharging or servicing.
USB-C CONNECTION
USB-C CONNECTION
This connecting terminal is compatible with most USB-C cables on the market.
We recommend you use the included cable to charge the PowerBolt.
CONNECTING YOUR MACHINE
HOW TO CHARGE YOUR MACHINE
Insert the provided USB-C cable into the back of the PowerBolt and connect to a Hover or power socket. Make sure the cable is properly seated and is fully inserted into PowerBolt. The PowerBolt is not designed to operate while plugged in. The USB-C connection is intended only for charging your PowerBolt.PowerBolt can be recharged while not attached to the Flux. If connecting to a Hover, the charge speed will be up to 1.0 A.
ADJUSTING NEEDLE DEPTH
ADJUSTING NEEDLE DEPTH
To adjust needle depth, hold the machine body and PowerBolt while turning the
Grip. A counter-clockwise turn decreases depth, while a clockwise turn
increases depth (also known as needle hang). Each time you turn the grip you
can feel the tactile feedback of the ratcheting mechanism. Each “click”
displaces your needle 0.2 mm and allows you to set your needle precisely
without involuntarily turning while tattooing.
eGIVE
eGIVE ADJUSTMENT
With this feature, you’ll be able to control the amount of “give” or
resistance of the needle upon impact with the skin, even on direct drive
tattoo machines. This enables the artist to take advantage of the softness or
hardness of the hit to achieve specific results. 0 has no effect, 5 offers the
maximum amount of eGive.
HOW TO CHECK THE CURRENT eGIVE SETTING
- Hold down the power button until the light goes from white to solid blue.
- Release the power button.
- The following blinking color that the LED displays indicate the give that the unit is currently set at. For example:
– a white blinking light indicates the lowest at 0 (zero)
– a yellow blinking light indicates level 1 eGive
– an orange blinking light indicates a softness of 2 eGive
– a red blinking light indicates a softness of 3 eGive
– a pink blinking light indicates a softness of 4 eGive
– a green blinking light indicates a softness of 5 (softest eGive setting)
CHANGING eGIVE
To increase or decrease the give:
– Hold down the power button until the light goes from white to solid blue.
– Release the power button and immediately use the up or down arrows to change
the give. The colors should change accordingly.
| | White – eGive of
0
---|---|---
| Yellow – level 1 eGive
| Orange – level 2 eGive
| Red – level 3 eGive
| Pink – level 4 eGive
| Green – level 5 eGive (softest setting)
ADDITIONAL INFORMATION
VOLTAGE PARAMETERS
While best voltage is a preference is a parameter that will vary from artist
to artist, this machine has been tested to operate at a minimum of 5 Volts and
a maximum voltage of 12 Volts. Depending on the type of needle configuration
or brand you use, feel free to adjust the voltage to obtain the desired
performance.
ACCEPTED NEEDLES
Use only cartridge needles with an internal membrane. This will avoid
accidental contamination inside your machine. Fluids such as ink, water, or
oil will void the warranty of the device and may require the replacement of
internal parts.
MAINTENANCE
- Flux is sold pre-lubricated from the factory and does not require internal lubrication.
- Prevent any type of external elements from entering inside the machine as they will disrupt the motion of the component and contaminate lubrication.
- The grip of the machine is autoclavable. Use only steam autoclaves at temperatures no higher than 270° Fahrenheit or 132.222° Celsius. Add a hint of ointment or PTFE grease around the internal opening of grip or on stabilizing friction O-rings for optimal functionality after autoclaving. Refer to page 5 for additional information.
- Machine Body and PowerBolt can be sanitized from the outside with cold sterilization products.
- Never spray the surface directly to prevent fluids from entering the machine. Always use pads or disposable paper towels to apply sterilization products.
- DO NOT DISASSEMBLE THE MACHINE.
WARRANTY
- All the housing components (Grip, Machine Body, and PowerBolt) are covered by a lifetime warranty.
- Internal parts are subject to wear and the motor itself will be covered by a 1-year warranty from the date of purchase.
- Motor warranty is void if motor shows signs of being dropped, of internal fluids entering the motor, and/or IF motor shows signs of being tampered with in any way.
ADDITIONAL INFORMATION
HANDY TIPS
The following tips will help you get the most out of your EXO and avoid
potential issues:
- Always secure your machine. Dropping the machine can cause damage to the magnets, bearings, and brushes of the motor.
- Use only cartridges with membranes to avoid contamination.
- Rinse your needle frequently to avoid pigment drying up and slowing down your cartridges. When rinsing your needle, ensure to dip only the tip of the cartridge to avoid backflow of fluids.
- Inspect your needles prior to use.
- Avoid scratching any part of the surface.
- Use only FDA-approved cold sterilization solutions for disinfection.
- Do not lubricate the machine unless instructed otherwise.
- Store your machine in a secure place.
- Before first use, charge the battery for a minimum of 3 hours.
TROUBLESHOOTING
-
Machine manufacturer
FK Irons: 1771 NW 79th Avenue, Doral, Florida 33126 -
Servicing your machine
Just like any mechanical device subject to use, FK Irons strongly suggests that you service your product at least once for a proper diagnosis of all working parts. This ensures the optimal condition of all working parts including internal machine clean up and fresh lubrication. Routine servicing will ensure that your machine remains functioning like the very first day. Service is subject to fees. -
Warning
Disconnect the machine from any power source before making any adjustments.
For service inquiries, please contact
service@fkirons.com.
For additional tips and tutorials, please visit Youtube.com/fkirons
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>