qtx PAR12 3 x 4W RGBW LED PAR Light User Manual

June 6, 2024
qtx

PAR12
3 x 4W RGBW LED PAR Light
Item ref: 154.033UK
User Manual
Version 1.1

Caution: Please read this manual carefully before operating
Damage caused by misuse is not covered by the warranty
Thank you for choosing PAR12 as part of your light show. The PAR12 is a compact DMX fixture that has been designed to be easy to set up as a small light show but with enough features to integrate into larger installations. Please read and keep the following instructions for future reference.

SAFETY SYMBOL AND MESSAGE CONVENTIONS
CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN
**** This symbol indicates that dangerous voltage constituting a risk of electric shock is present within this unit
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.

Warning

To prevent the risk of fire or electric shock, do not expose any components to moisture. If liquids are spilled on the casing, stop using immediately, allow the unit to dry out, and have checked by qualified personnel before further use. Avoid impact, extreme pressure or heavy vibration to the case. No user- serviceable parts inside — Do not open the case — refer all servicing to qualified service personnel.

Safety

Check for correct mains voltage and condition of IEC lead before connecting to power outlet Do not allow any foreign objects to enter the case or through the ventilation grilles

Placement

  • Keep away from damp or dusty environments
  • Use the included bracket for installation and ensure all fixings are secure
  • Ensure adequate air-flow around the housing
  • Ensure adequate access to controls and connections
  • Avoid aiming directly towards eyes at close range

Cleaning

  • Use a soft cloth with a neutral detergent to clean the casing as required
  • Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
  • Do not use strong solvents for cleaning the unit

Power Connection

The PAR12 is hard-wired to a UK plug top. Connect this to a suitable outlet, ensuring the correct voltage. If the power is to be spliced into the mains by a different method, this must be carried out by a qualified electrician.

Rear Panel

  1. DMX input XLR
  2. LED display
  3. Power cable
  4. DMX output XLR
  5. Menu buttons

Internal Settings

Using the menu buttons (5) the PAR12 can be set to run in various modes. These are outlined in the table below.

Function Display Press Up/Down Press Enter + Up/Down
DMX address setting
Slave mode (IP mode)
Auto 1 static colors
Auto 2 color change
Auto 3 fade programs

Auto 4 sound-activated
Auto 5 strobe programs
Red custom level| Static Red level 0-100%
Green custom level| Static Green level 0-100%
Blue custom level| Static Blue level 0-100%
White custom level| Static White level 0-100%

DMX Connection

The PAR12 has a male XLR and female XLR on the rear panel (1, 4) for DMX512 control or connection to other PAR12 units for Master/Slave operation. Link in sequence from DMX OUT to DMX IN connectors using good quality 3-pin XLR leads that are suitable for DMX.

DMX Functions

Channel Value Description
CH1 000 – 010 No function
011- 050 Auto program 1
051- 100 Auto program 2
101- 150 Auto program 3
151- 200 Auto program 4
201- 255 Auto program 5
CH2 000 – 039 All colors
040 – 049 Red
050 – 059 Green
060 – 069 Blue
070 – 079 Yellow
080 – 089 Cyan
090 – 099 Purple
100 – 109 White
110 – 119 Red + Green
120 – 129 Red + Blue
130 – 139 Red + White
140 – 149 Green + Blue
150 – 159 Green + White
160 – 169 Blue + White
170 – 179 Red + Green + White
180 – 189 Red + Blue + White
190 – 199 Green + Blue + White
200 – 209 Red + Green + Blue
210 – 255 Red + Green + Blue + White
CH3 000 – 255 Speed setting
CH4 000 – 255 Master dimming
CH5 000 – 255 Red dimming
CH6 000 – 255 Green dimming
CH7 000 – 255 Blue dimming
CH8 000 – 255 White dimming

DMX operation

In order to access the DMX functions, the DMX start address will need to be set on the control panel (or from the remote control – see below).
When the display shows “d001”, this means that the PAR12 is operated by channels 1-8 as detailed on the previous page. When the display shows “d203”, this means that the PAR12 is operated by channels 203-210.
The start address can be anywhere between 001 and 512

Standalone operation

The PAR12 can be operated without external control by selecting one of the Auto or custom static color settings from the control panel menu. These are shown in the Internal Settings section on page 3 of this manual.
Internal settings can also be selected via the included IR remote control as detailed below.
As supplied, the remote handset has a clear plastic tab inserted which should be removed to activate the CR2025 button cell. Point the handset toward the front of the PAR12 unit at a range of no more than 5m for remote control.

1. Power on/off
2. Auto 1 static colors
3. Auto 3 color fade
4. Static color –
5. Program speed-
6. DMX address –
7. IP slave ID –
8. IP slave mode select| 9. Auto 4 sound activated
10. Auto 2 color change
11. Auto 5 strobe
12. Static color +
13. Program speed +
14. DMX address +
15. IP slave ID +
16. DMX mode select
---|---

Master/slave operation

A PAR12 fixture operating in one of the standalone modes may be connected to further PAR12 units by DMX lead (XLR-XLR) as a master unit. The slave units must be set to “IP” mode to mimic the operation of the master unit.
The LED display will show “IP” followed by two digits, which is the IP number. The IP the number is not used in the PAR12 and any setting from IP01 to IP64 will operate as slave mode (IP numbers are only used in different types of fixtures)
When IP mode is selected, the PAR12 will mimic any DMX input from another PAR12 operating in standalone Auto or Static Colour mode.

Specifications

Power supply 100 – 240Vac, 50/60Hz
Power consumption 15W
LEDs 3 x 4W RGBW
Connections DMX in/out (XLR)
Operating temperature range -20 to +40°C
DMX channels 8
Beam angle 25°
Dimensions 120 x 115 x 110mm
Weight 408g

This product is classed as Electrical or Electronic equipment and should not be disposed of with other household or commercial waste at the end of its useful life. The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright(E) 2021 AVSL Group Ltd, Unit 2 Bridgewater Park, Taylor Road, Trafford Park, Manchester. M41 73Q.
AVSL (Europe) Ltd, Unit 3D North Point House, North Point Bus. Park, New Mallow Road, Cork, Ireland.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals