BLAZE PowerZone 1004 Power Amplifier User Guide
- June 6, 2024
- BLAZE
Table of Contents
BLAZE PowerZone 1004 Power Amplifier User Guide
Carton Contents
- Amplifier unit
- Output connector x 1 or 2
- Mains power cable
- Adhesive rubber feet x 4
- Input connector x 1 or 2
- Document pack
- GPIO socket connector
- Rack Ears (PowerZone 1004)
Connections
DIP Switch Functions
SWITCH| OFF ↓| ON ↑|
---|---|---|---
1| Channel 1 in Low-Z mode| Channel 1 in Hi-Z mode|
2| Channel 2 in Low-Z mode| Channel 2 in Hi-Z mode|
3| Channel 3 in Low-Z mode| Channel 3 in Hi-Z mode|
4| Channel 4 in Low-Z mode| Channel 4 in Hi-Z mode|
5| 70V Hi-Z mode
(for channels in Hi-Z mode)
| 100V Hi-Z mode
(for channels in Hi-Z mode)
|
6| Input ganging 1: All| Input ganging 1:1|
7| GPIO standby polarity NO (Normally Open)| GPIO standby polarity NC
(Normally Closed)|
8| Front panel control locked.| Front panel control unlocked.|
- Not applicable to two channel amplifiers.
Installation Notes
- Ensure that rack or other confined installation does not restrict the airflow required for safe and reliable operation of the equipment. It is important to ensure that the 40°C maximum operating temperature for the equipment is not exceeded.
- Amplifiers will not switch on from standby mode unless an input signal is present or the standby switch is toggled.
GPIO Functions
Support
- A full user manual that includes information on installation, mounting accessories and amplifier operation is available online. Go to www.blaze-audio.com or scan the QR code.
Read More About This Manual & Download PDF:
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>