BLAZE BLZ-60 60 Inch Rectangular Concrete Propane Fire Pit Table Owner’s Manual

May 15, 2024
BLAZE

BLAZE BLZ-60 60 Inch Rectangular Concrete Propane Fire Pit Table

BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table-
PRO

Product Information

The Rectangle Fire Table, model BLZ-60-FTABLE-LP, is designed for outdoor use only. It operates using propane (LP) gas from an 11 lb LP Gas Tank, providing a heat output of 60,000 BTUs/hr. Please read and follow all safety instructions and guidelines before use.

Specifications

  • Product Name: Rectangle Fire Table
  • Model No.: BLZ-60-FTABLE-LP/142LP
  • Type of Gas: Propane (LP) Gas
  • Gas Supply: 11 lb LP Gas Tank
  • Rated Heat Output: 60,000 BTUs/hr

Usage Instructions

Assembly Instructions
Refer to the Parts List and Assembly Instructions provided in the manual to properly assemble the fire table. Make sure installation and service are performed by a qualified professional.

Pre-Use Instructions
Before using the fire table, ensure that it is placed in a well-ventilated outdoor area. Do not operate the appliance in enclosed spaces. Keep flammable materials away from the fire table.

Lighting Instructions
Follow the Lighting Instructions carefully to safely ignite the fire table. Use a long-reach lighter or match to light the burner. Do not attempt to light the appliance in windy conditions.

Care and Cleaning
Regularly clean the fire table following the Care and Cleaning instructions provided. Avoid using abrasive cleaners that may damage the finish.

Spider and Insect Warning
Be cautious of spiders and insects that may build nests or webs in or around the fire table. Regularly inspect and clean the unit to prevent blockages or malfunctions.

Tips and Troubleshooting
Refer to the Tips and Troubleshooting section for guidance on maintaining optimal performance and addressing common issues with the fire table.

FAQs

  • Q: Can I use this fire table indoors?
    A: No, this fire table is designed for outdoor use only. Using it indoors can lead to carbon monoxide hazards.

  • Q: How should I store the LP gas tank?
    A: Store the LP gas tank in a well-ventilated outdoor area, away from heat sources or ignition points. Never store it in enclosed spaces.

IMPORTANT SAFETY INFORMATION

DANGER CARBON MONOXIDE HAZARD
This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home.

DANGER – FIRE OR EXPLOSION HAZARD

If you smell gas:

  • Shut off gas to the appliance.
  • Extinguish any open flame.
  • If odor continues, leave the area immediately.
  • After leaving the area, call your gas supplier or fire department.
    Failure to follow these instructions could result in fire or explosion, which could cause property damage, personal injury, or death.

WARNING: FOR OUTDOOR USE ONLY.
Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

  • INSTALLER: Leave this manual with the appliance.
  • CONSUMER: Retain this manual for future reference.
  • WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, serious injury, or loss of life.
  • WARNING: Do not store or use gasoline or other flammable v apors and liquids in the vicinity of this or any other appliance. An LP gas tank not connected for use shall not be stored in the vicinity of this or any other appliance.

SPECIFICATIONS

  • Product Name Rectangle Fire Table
  • Model No. BLZ-60-FTABLE-LP/ 142LP
  • Rated Heat Output 60,000 BTUs/hr
  • Type of Gas Propane (LP)
  • Gas Supply 11 lb LP Gas Tank

ATTENTION
Please register your fireplace for recall notifications, proof of ownership and quality assurance at https://www.realflame.com/registration.

DANGER • FLAMMABLE GAS UNDER PRESSURE. LEAKING LP-GAS MAY CAUSE A FIRE OR EXPLOSION IF IGNITED CAUSING PROPERTY DAMAGE, BODILY INJURY OR DEATH. CONTACT LP GAS SUPPLIER FOR REPAIRS OR DISPOSAL OF THIS CYLINDER OR UNUSED LP-GAS.

WARNING • FOR OUTDOOR USE ONLY. DO NOT USE OR STORE CYLINDER IN A BUILDING, GARAGE OR ENCLOSED AREA.

WARNING:

  • Know the odor of LP-gas. If you hear, see or smell leaking LP gas, immediately move everyone away from the cylinder and call the Fire Department. Do not attempt repairs.
  • Caution your LP-gas supplier to:
    • Be certain cylinder is purged of trapped air prior to first filling.
    • Be certain not to over fill the cylinder.
    • Be certain cylinder requalification date is checked.
  • LP-gas is heavier than air and may settle in low places while dissipating.
  • Contact with the liquid contents of cylinder will cause freeze burns to the skin.
  • Do not allow children to tamper or play with cylinder.
  • When not connected for use, keep cylinder valve turned off. Self-contained appliances shall be limited to a cylinder of 30 lb capacity or less.
  • Do not use, store or transport cylinder where it would be exposed to high temperatures. Relief valve may open allowing a large amount of flammable gas to escape.
  • When transporting, keep cylinder secured in an upright position with cylinder valve turned off.

WHEN CONNECTING FOR USE:

  • Use only in compliance with applicable codes.
  • Read and follow manufacturer’s instructions.
  • Consult manufacturer’s instructions concerning the cylinder connection provided with your appliance.
  • Be sure regulator vent is not pointing up.
  • Turn off all valves on the appliance.
  • Do not check for gas leaks with a match or open flame. Apply soapy water at areas marked “X”. Open cylinder valve. If bubble appears, close valve and have LP-gas service person make needed repairs. Also, check appliance valves and connections to make sure they do not leak before lighting appliance.
  • Light appliance(s) following manufacturer’s instructions.
  • When appliance is not in use, keep the cylinder valve closed.

DO NOT REMOVE, DEFACE OR OBLITERATE THIS LABEL EXCEPT AS AUTHORIZED BY ANSI/NFPA 58.

DANGER. Do not store a spare LP cylinder under or near a barbecue grill or other heat sources.
NEVER fill an LP cylinder beyond 80% full: a fire causing property damage, serious injury or death may occur.

General Warnings

  • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
  • Children should be carefully supervised when in the area of the fireplace.
  • Clothing or other flammable materials should not be hung from the fireplace or placed on or near the fireplace.
  • Any guard or other protective device removed for servicing the fireplace must be replaced before operating the fireplace.
  • Installation and service must be performed by a qualified service agency or gas supplier. Real Flame recommends using professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as NFI Gas Specialists.
  • More frequent cleaning may be required as necessary. The control compartment, burners, and circulating air passageways of the appliance must be kept clean.
  • Do not store or use gasoline or other flammable vapours or liquids within 25 feet (7.62 m) of this fireplace or any other appliance.
  • Do not store combustible materials in the fireplace enclosure. This includes LP gas tanks. If the fireplace is designed to use a hidden LP gas tank, the LP gas tank should be properly secured in the designated tank holder under the fireplace. Do not store extra LP gas tanks under the fireplace.
  • Be sure to protect the hose and its components from any hot surfaces. It is dangerous to allow the hose to come into contact with any hot surface.
  • The LP gas tank should never be operated or stored on its side or upside down.
  • Keep all parts of the fireplace clean including the burner and hose assembly. For more information on cleaning your fireplace please refer to the “Care and Cleaning” section of this manual.
  • Do not use this fireplace if any part has been underwater. Immediately call a qualified service technician to inspect the fireplace and replace any part of the system that has been under water.
  • Do not use this fireplace for cooking.
  • Do not pour water into the fireplace.
  • Do not attempt to move or store this fireplace until all parts are cool.
  • Always shut off the gas supply at the source and disconnect the hose when the fireplace is not in use.
  • Any alteration of this fireplace that is not specifically directed in the owner’s manual will void the manufacturer’s warranty. This includes the use of unapproved filler materials.

Installation Warnings

  • Minimum clearance from the fireplace to combustible materials is 60 inches (152.4 cm) from top and 48 inches (121.9 cm) on all sides. Do not place this fireplace under any overhead structure or vegetation.
  • The normal LP inlet pressure for this fireplace is 11.0” W.C. (2.74 kPa). Maximum inlet pressure is 13.0” W.C. (3.23 kPa). Minimum inlet pressure is 8” W.C. (1.99 kPa).
  • Do not remove the feet from this fireplace.
  • Do not place the fireplace on anything that blocks or seals the gap between the fireplace and the ground.
  • Do not permanently secure the fireplace in any way or to any surfaces.
  • Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
  • The hose could be damaged if it touches hot surfaces.

Set Up Warnings

  • Before each operation, check the hose assembly for evidence of excessive abrasion, wear or damage. Use a handheld mirror, if necessary, to see the hose sections located below the unit.
  • If the hose assembly is damaged, cracked, or cut, it must be replaced before using the fireplace. The hose assembly must be replaced with a hose assembly specified by Real Flame. Please contact Real Flame Customer Service at 1-800-654-1704 for assistance.
  • Place the hose out of the pathways where people may trip over it. Do not place the hose in areas where it may be accidentally damaged.
  • Before each use, examine the burner and its components for dirt and debris. If cleaning is required, use a pipe cleaning brush and compressed air. Also examine the area around the burner. Any dirt or foreign material, such as spider webs, nests, leaves, etc., should be removed. If it is evident that the burner is damaged, the fireplace must not be used, and the burner assembly must be replaced. Please contact Real Flame Customer Service at 1-800-654-1704 for support.

In-Use Warnings

  • NEVER LEAVE this fireplace unattended when in use.
  • Do not burn solid fuels, such as charcoal briquettes, lump charcoal, manufactured logs, trash, leaves paper, cardboard, any type of natural or treated wood, or any other materials in this fireplace.
  • The use of alcohol, prescription or non-prescription drugs may impair your ability to safely operate this fireplace.
  • Always use by all applicable local, state, and national codes. Contact your local fire department for details on outdoor burning.
  • Do not use in windy conditions. Windy conditions may cause the flame to drift out of the designated burn area or may cause the flame to extinguish. Prolonged exposure to wind with the fire table in operation can damage the finish around the burner area, causing discolouration or cracking.
  • Some surfaces of this fireplace may become hot during use. Be careful and do not touch surfaces until the unit has cooled.
  • Do not attempt to disconnect the gas supply from the fireplace when the unit is in use.
  • Do not sit on the fireplace.

PROPANE (LP) GAS DANGERS AND WARNINGS

WARNING
LP gas is flammable and hazardous if handled improperly. Become aware of its characteristics before using any LP gas product. Failure to understand and follow these warnings or any directions and warnings provided by your LP gas supplier may result in property damage, serious injury, or death.

DANGER
An LP gas tank should never be placed on its side. Doing so may cause liquid propane to leak. This could cause a fast buildup of LP gas and could lead to property damage, serious injury, or death.

LP Gas Characteristics

  • • LP gas is flammable, explosive under pressure, heavier than air and settles in pools in low areas. Pooled gas may ignite causing a fire or explosion which could cause property damage, serious injury, or death.
    • In its natural state, LP gas has no odour. For your safety, a scent has been added.
    • Contact with LP gas could burn your skin.

LP Gas Tank Information

  • LP gas tanks should be filled only by a certified LP gas dealer.
  • Never use an LP gas tank with a damaged body, valve, collar or footing.
  • Dented or rusted LP tanks may be hazardous and should be checked by your LP gas supplier.
  • The LP gas supply tank must be constructed and marked by The Specifications for LP Gas Tanks of The U.S. Department of Transportation (DOT) or The National Standard of Canada, CAN/CSA-B339, LP Gas Tanks, Spheres and Tubes for
  • The Transportation of Dangerous Goods; and Commission.
  • LP gas tanks must be arranged for vapour withdrawal.
  • LP gas tanks must have a listed overfilling prevention device (OPD) and a QCCI or Type I (CGA810) LP gas tank connection.
  • The LP gas tank must contain a shut-off valve as specified in The Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96.
  • Never attempt to attach this fireplace to the self-contained LP gas system of a camper, trailer, motor home or house.
  • Hand-turn the manual gas control valve on your LP gas tank. Never use tools. If the valve will not turn by hand, do not try to repair it. Call a certified gas technician.
  • The use of force or any attempt at amateur repair may cause a fire or explosion.

LP Gas Tank Storage and Safety

  • LP gas tanks must be stored upright and outdoors in a well-ventilated area out of reach of children.
  • Never store an LP gas tank in an enclosed area, such as a shed or garage. Leaking gas could build up in these areas and may result in an explosion.
  • Do not store LP gas tanks near any source of flame or ignition.
  • Never store an LP gas tank in direct sunlight or where temperatures can reach 125°F (51.67°C) or higher.
  • Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure to increase, which may open the relief valve and allow gas to escape.
  • Place the dust cap on the LP gas tank valve outlet when the LP gas is not in use. Only use the dust cap that is provided with the LP gas tank. Other types of caps or plugs may result in leakage of LP gas.
  • The LP gas tank should not be dropped or handled roughly.

PARTS LIST

BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table-
\(2\) BLAZE-BLZ-60-60-Inch-
Rectangular-Concrete-Propane-Fire-Pit-Table- \(3\)

ASSEMBLY INSTRUCTIONS

  1. Place the filler material into the burner pan by hand. To avoid clogging the burner with dust do not dump the bag into the burner pan. Position the filler across the burner pan to a level that is 1 inch (2.54 cm) above the burner tube. Make sure you do not block the igniter housing with the filler material to ensure proper ignition and operation.
    If using glass filler, Real Flame suggests first placing a layer of lava rock in the burner pan to improve airflow.BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-
Propane-Fire-Pit-Table- \(4\)

    • Filler Material Warning
    • Do not overfill the burner area with rock or glass filler; use only the specified amount. The depth of the filler should not be more than 1 inch (2.54 cm) above the burner tube. Only Real Flame filler products have been certified and tested for safe use with this Real Flame fireplace. Using other filler material may result in increased popping and cracking or increased carbon monoxide emissions.
    • Do not light or use this fireplace if the filler is wet. Ensure filler is completely dry before lighting. Intense heat can cause wet filler to explode and hit someone causing property damage, serious injury, or death.
    • Keep away from the fireplace for at least 20 minutes during initial start-up as filler could retain moisture from manufacturing and shipping.
  2. Have your 11 lb. Propane tank filled at a local LP refill location. The tank ships empty and must be filled before using your fire table.
    Once filled, place the LP tank in the designated location just inside the access door of your fire table.BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-
Propane-Fire-Pit-Table- \(5\)

  3. Once the tank is placed in the designated area, secure it in place by tightening the thumbscrew on the tank seat.BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table- \(6\)

  4. Connect the LP Gas Tank

    • Before connection, be sure there is no debris caught in the collar of the LP gas tank, the regulator valve, the burner tube, or the burner ports.BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table- \(7\)

    • Connect the gas line to the tank by turning the connection knob clockwise. Hand-tighten only.
      Disconnect the LP Gas TankBLAZE-BLZ-60-60-Inch-Rectangular-Concrete-
Propane-Fire-Pit-Table- \(8\)

    • To disconnect the LP gas tank, make sure the valve on the LP gas tank is completely closed.

    • Disconnect the connection knob by turning it counterclockwise until it is detached from the valve.

WARNING
If the table is installed with a portion of the hose under the table, the hose must be secured, so that no part of the hose will be within 1” or come in contact with the underside of the burn pan or where the hose will not be accidentally damaged or pinched. Failure to secure the hose in a safe location may result in a gas leak that could cause property damage, injury, or death. Follow all other hose inspection instructions listed in this manual.

PRE-USE INSTRUCTIONS

WARNING Before using this fireplace, make sure you have read, understand, and are following all information provided in this manual. Failure to follow these instructions could cause property damage, serious injury, or death.

Checking for Leaks

  1. Make a leak check solution by mixing 1 part dishwashing soap with 3 parts water in a spray bottle.
  2. Make sure the control knob on the fireplace is in the “OFF” position, then connect your fireplace to the LP gas tank and turn the tank’s valve on.
  3. Spray the leak solution on the valve connections, paying particular attention to the areas indicated by arrows in the diagrams below.
  4. If bubbles appear, turn the LP gas tank off, disconnect the tank, and inspect all connections, making sure threads are clear of debris. Reconnect the LP gas tank and retest. If you continue to see bubbles, turn the LP gas tank off. Disconnect the hose and call Real Flame Customer Service at 1-800-654-1704 for assistance.
  5. If no bubbles appear after 1 minute, wipe away the excess leak solution and proceed to “Lighting Instructions.”

BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table-
\(10\)

LIGHTING INSTRUCTIONS

Lighting the Fireplace

  1. Read and understand all operating instructions before lighting.
  2. Before beginning, make sure the key valve is in the “OFF” position.
  3. Connect the gas line to the tank by turning the connection knob clockwise. Hand-tighten only.
  4. Slowly open the valve on your LP gas tank.
  5. Position a burning long match or long burning butane lighter near the side of the burner.
  6. Insert the key and slowly turn the key valve counterclockwise toward the “ON” position.
  7. Once the burner has been lit, remove the match/lighter. Observe the flame and make sure that all of the burner ports are lit.
  8. Adjust the flame to the desired height using the key valve.
    WARNING: If ignition does not occur in 15 seconds, turn the key valve to the “OFF” position and turn the gas off at its source. Make sure there is no source of ignition around the fireplace and wait at least 5 minutes until the gas has cleared to repeat the lighting procedure. Failure to do so could result in a large flashback of collected gas, causing property damage, serious injury, or death.BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-
Table- \(11\)

Shut-Off Instructions

  1. Turn the key valve clockwise to the “OFF” position.
  2. Once the flame is out, remove the key and close the valve on the LP gas tank to shut off gas flow.
  3. Store the key in a safe location. If the key is lost please contact Real Flame Customer Service at 1-800-654-1704 for a replacement.

CARE AND CLEANING

Inspecting Your Fireplace

WARNING
DO NOT inspect, clean, move or store your fireplace until the flames are COMPLETELY out and all parts are cool to the touch.

Your fireplace should be inspected regularly to ensure that it is safe to use and to extend the life of its parts.
Inspect your fireplace:

  1. Make sure all parts are securely fastened in place. If a part moves when touched, check its connection points to see if they are loose.
  2. Check all connections for leaks using the method described in the “Checking for Leaks” section of this manual.
  3. Visually check all components for any signs of damage, rust, or excessive wear.
  4. If damage or leaks of any kind are found. DO NOT operate the fireplace until the proper repairs have been made.

WARNING
DO NOT tamper with this fireplace. This is dangerous and will void the warranty. Repairs and modifications must be approved by Real Flame and completed by a professional gas technician. This fireplace has been tested and certified by a third-party certification agency based on its specific and unique parts. Installing any other parts will void both the certification and the warranty. For approved replacement parts contact Real Flame Customer Service at 1-800-654-1704.

General Care and Cleaning
After repeated use, a slight discolouration or weathering of the fireplace finish may occur. Your fireplace should be cleaned regularly to ensure safe use and extend its life.

  • General Cleaning
    Make a cleaning solution using a mild soap mixed with water. Use a soft cloth to wipe down exterior surfaces and rinse with clean water. Never use oven cleaners or abrasive solvents as these will damage the fireplace.

  • Burner
    The burner should be kept clean to ensure proper operation. Clogged burner ports may be cleared with a paper clip or pin. Debris in the burner tube can be cleaned using compressed air or a pipe-cleaning brush.

  • Soot
    After use soot can develop on some surfaces. This soot deposit will usually come off with water and mild soap.

  • Sealing
    To maintain the fireplace finish it is recommended to reseal the table surface with a water-based sealer, annually. Resealing will restore the beauty of the finish and further protect the fireplace.

Storage

  1. Turn the LP gas supply off at the tank. Remove the LP gas tank and store it in a cool, dry location, outside and away from children.
  2. Secure all loose filler material or parts.
  3. Cover the fireplace when not in use and do not allow water to pool on the cover surface. Covering the fireplace will help to protect the internal components from dirt and debris and prevent the finish from fading.
  4. Store the fireplace in a cool, dry location away from children and pets.

SPIDER AND INSECT WARNING

Spiders or other insects may build webs or nests in your fireplace burner tube which can obstruct or block the flow of gas. Some of the gas may back up in the burner tube and cause a flashback (a fire in the burner tube or underneath the fireplace), which could result in property damage, serious injury, or death. Check and clean the burner tube periodically using a pipe cleaning brush (shown below) and compressed air available at any hardware store.BLAZE-
BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table-
\(12\)

TIPS AND TROUBLESHOOTING

If the Fireplace Will Not Ignite or Stay Lit
Make sure the gas tank is fully open by twisting the knob counterclockwise and that the connection between the hose and the tank is correct. Verify that the key valve is not stripped out and that the valve is opening and closing. Make sure the hose does not have any kinks or sharp bends.

Other Common Problems

  • Clogged or Obstructed Burner
    It is common for bugs, especially spiders, to make webs or nests inside of burner tubes. If it seems like you are getting low or no gas flow, visually check all openings in the burner for signs of clogs. If you see anything clogging the burner using a pipe cleaner or compressed air to remove the debris.
    Out of Gas
    Be sure your LP gas tank is not empty. Low tanks can result in lower flames.

  • Cold Temperatures
    Cold temperatures outside may result in lower LP gas tank pressures causing the flames to be lower. Do not use your fireplace in extreme temperature conditions. Allow the temperature of your LP gas tank to rise and as the pressure in the LP gas tank increases the flame size will increase. NEVER heat your LP gas tank; allow it to warm up naturally.

  • High Winds
    Your fireplace is designed to operate in winds up to 10 mph (16.09 kph). High winds may cause the flame to blow out. Do not operate your fireplace in high wind conditions.

If you continue to have problems with your fireplace please contact Real Flame Customer Service at 1-800-654-1704.

TECHNICAL PARTS LIST

BLAZE-BLZ-60-60-Inch-Rectangular-Concrete-Propane-Fire-Pit-Table-
\(13\)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals