Alecto SA-19/1 Smoke Detector Instruction Manual
- June 6, 2024
- Alecto
Table of Contents
SA-19/1 Smoke Detector
Instruction Manual
Smoke detector for domestic use
The SA-19/1 is a smoke detector set for the discovery of fire in the first
stage. If smoke develops, the SA-19/1 will give a loud beep of at least 85dB
(A). As part of the link function, all the smoke alarms within range will
sound the alarm. We advise testing the smoke detectors weekly using the test
button on the detectors.
Save this manual in a safe place or inside the electricity meter cupboard.
RECOMMENDED INSTALL LOCATIONS FOR THE SA-19/1:
- Install the first smoke detector near the bedroom. Ensure that it is placed so, if it would detect fire, at least one exit route would still be accessible. We recommend placing one alarm near each potential blockade of your exit route, so you are alerted before a fire would block off escape.
- Use multiple smoke detectors to increase safety and ensure an alert before the escape route is blocked.
- Install at least one smoke detector on each floor of your house.
- Install at least one smoke detector in each room where people smoke or where there is equipment that may potentially cause a fire.
- Smoke and heat will first move upwards towards the ceiling; after that, the smoke and heat will travel horizontally.
- Install the detector on the ceiling. Except for rooms smaller than 1m, you should stay at least 50 cm away from the wall and 61cm from any corner. Smoke and heat do not gather in such corners, preventing the detector from alerting you on time.
DO NOT INSTALL IN THE FOLLOWING LOCATIONS:
- The kitchen; Steam from cooking might give a false alarm.
- In the shower or bathroom; water damping might cause a false alarm and the moist environment might damage the detector.
- The garage: The car exhaust might cause a false alarm.
- In front of a fan or nearby the exhaust of an air conditioner or heater.
- In a ceiling nook.
- In rooms where the temperature could reach below -10°C or beyond 40°C.
- Do not paint or otherwise cover this smoke detector.
INSTALLATION INFORMATION:
Attach the ceiling plate using the included plugs and screws to the ceiling at
a location of choice. Wall mounting is not recommended for smoke detection.
Put the 9V block battery in the smoke detector. Then put the detector to the
ceiling plate and, twist clockwise to lock it in place. Perform the first test
by holding the test key for two seconds. Also see the paragraph: “Testing”.
USING, TESTING AND MAINTENANCE:
Using:
The smoke detector works if the 9V battery has been placed and the SA-19/1 has
been mounted to the ceiling. The unit can only be mounted to the plate if the
battery has been installed. The LED underneath the test button will now flash
± every 45 seconds. Once smoke is detected, the alarm will sound. Once the
smoke disappears, the smoke alarm will stop automatically
Time-out function:
With this function, the sensitivity of the alarm is reduced by about 10
minutes. This function can be switched on by pressing the “TEST/HUSH” button
once. The sensitivity of the smoke detector is automatically reduced and the
indicator light will briefly light up ± every 10 seconds to indicate that the
sound is temporarily muted. The alarm is reactivated after 10 minutes. If
there is still smoke, the alarm sound will be heard again. This function can
be used repeatedly.
Test:
Hold the test key for at least 2 seconds. The operation is still correct if
you hear 2 or three signal tones. Check the smoke detectors weekly. In alarm
status, the smoke detector will generate about 85dB(A). Do not use candles,
open fire, or cigarettes to test the smoke detector.
ATTENTION:
- If the cause of an alarm is unclear, assume it’s caused by fire. Immediately evacuate the building.
- Keep the smoke detectors out of range of children.
- Protect against dust during renovations. Without protection, the smoke detectors will lose their functionality.
Maintenance:
The smoke detector is maintenance-free. In very dusty rooms they may be
cleaned by vacuum.
PLAN AN ESCAPE ROUTE:
- Make a map and mark all locations of doors and windows and a possible escape route. Note that you may need an escape ladder on high floors.
- Ensure everyone in the house knows the sound the smoke alarms produce and regularly practice use of the escape route.
- Leave the house immediately according to the plan when hearing the alarm. Every second counts: so respond quickly. If you do not notice smoke or heat, check if everyone in the house is in a secure location.
- Do not open any doors without feeling whether the door is warm or if there is smoke coming from underneath the doors. If it is, do not open that door. If the door is cold, put your shoulder firmly against the door and open it a small amount to check for any heat or smoke first.
- If there is much smoke, keep low and take shallow breaths, preferably through a moist towel. Call the fire department as soon as you are safe outside.
REPLACING THE BATTERIES:
The detector is supplied using a 9Volt block battery. Only use the recommended
type Pairdeer 6F22. Under normal conditions, the battery will last at least
one year. If it is about to need replacement, the smoke detector will make a
chirping sound every 30 to 40 seconds for at least 30 days. Pay attention to
the polarity when replacing batteries. Test the detector after every battery
replacement. If the smoke detector does not function, please contact your
supplier.
ENVIRONMENT:
Do not throw away used batteries, but recycle them using your local chemical
depot. Product may not be thrown out as normal waste but must be recycled as
electrical waste.
DECLARATION OF CONFORMITY:
Available to download from: DOC.hesdo.nl/SA-19_1_DOP_1.pdf
Photoelectric Smoke Alarm Device
SA-19/1 (KD-127B)
EN14604 : 2005 / AC: 2008
DOP nr.: SA-19_1_DOP_1
1134-CPR-209
Hesdo b.v.
Aziëlaan 12
5232 BA ‘S-Hertogenbosch
The Netherlands
(+31) (0)73 6411 355
Fire detection in buildings
Essential characteristic 1: Pass
Essential characteristic 2: Pass
Essential characteristic 3: Pass
Essential characteristic 4: Pass
Essential characteristic 5: Pass
Essential characteristic 6: Pass
Essential characteristic 7: Pass
Essential characteristic 8: Pass
Mounting type | Ceiling |
---|---|
Main power source | Battery, 9V block, inc. |
Autonomy | At least: 1 year |
Interconnectible device | No |
Suitable for installation in a recreational vehicle | No |
Individual alarm indicator | Yes |
Alarm prevention facility | Yes |
WWW.ALECTO.NL
SERVICE@ALECTO.NL
Hello, Australiëlaan 1
5232 BB, ‘s-Hertogenbosch
The Netherlands
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>