Overview

Using WiAPC and Termination Board to provide power to WiAPBs. WiAPC/Termination board powers WiAPBs from inside the cabinet.board
1

Cabinet

  • WiAPC places calls into the traffic controller.
  • 9-Pin cable needs to be installed from the WiAPC to the terminals of the PED CALLS in the cabinet. (9-Pin cable included)
  • Utilizes the existing or new Field Wires from cabinet to pedestrian push buttons. (For power only).
  • Connect the Field Wires from the cabinet onto the termination board.
  • Termination Board: It is recommended, for troubleshooting purposes to use the “A” terminals for power and “B”terminals as common. Also use termination board slot #1for WiAPB ”1”, slot #2 for WiAPB “2”, and so on for all the push buttons.

NOTE : For NEW intersection installations, in the absence of city or other local specifications, Campbell Company recommends IMSA 14 Gauge (loop detector wire).

WiAPB
Warranty void if WiAPB is installed upside down.board
3

WiAPB Base Station
(Close up view of terminal block in front)board 4

WiAPB wiring connections 16 VAC Not polarity dependent.

Cabinet wiring

board 5

Recommended setup

board 6

For complete documentation visit http://www.pedsafety.com/product- installation-guides/ ©Campbell Company 2017