MSE3OZ
Z-Wave Plus Multipurpose Sensor
FEDERAL COMMUNICATIONS COMMISSION(FCC)STATEMENT FCC CautionThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and(2)this device must accept any interference received including interference that may cause undesired operation. Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC RulesThese limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -Reorient or relocate the receiving antenna- Increase the separation between the equipment and receiver -Connect the equipment into an outlet on a circuit different from that to which the receiver is connected -Consult the dealer or an experienced radio / TV technician for help.
WARRANTY
Moston Products warrants this product to be free from manufacturing defects for a period of two years from the original date of consumer purchase. This warranty is limited to the repair or replacement of this product only and does not extend to consequential or incidental damage to other products that may be used with this product. This warranty is in lieu of all other warranties, expressed or implied. Some states do not allow limitations on how long an implied warranty lasts or permit the exclusion or limitation of incidental or consequential damage, so the above limitations may not apply to you. This warranty gives you specific rights, and you may also have other rights which vary from state to state. if the unit should prove defective within the warranty period.
SPECIFICATIONS
Model:MSE302 Power: CR2450 3V Signal (Frequency): 908.42 ME.
Range: Up to 100 feet line of sight between the Wireless Controller and the
closest 2-Wave” receiver module. Operating Temperature Range: 5-104° F
(-10-40° C)
Specifications subject to change without notice due to continuing product
improvement
Website: www.nie-tech.com
WARNING’
RISK OF FIRE RISK OF ELECTRICAL SHOCK RISK OF BURNS CONTROLLING APPLIANCES: EXERCISE EXTREME CAUTION WHEN USING Z -Wave” DEVICES TO CONTROL APPLIANCES. OPERATION OF THE Z-Wave DEVICE MAY BE IN A DIFFERENT ROOM THAN THE CONTROLLED APPLIANCE, ALSO ANUNINTENTIONAL ACTIVATION MAY OCCUR IF THE WRONG BUTTON ON THE REMOTE IS PRESSED. Z-Wave DEVICES MAY AUTOMATICALLY BE POWERED ON DUE TO TIMED EVENT PROGRAMMING. DEPENDING UPON THE APPLIANCE, THESE UNATTENDED OR UNINTENTIONAL OPERATIONS COULD POSSIBLY RESULT IN A HAZARDOUS CONDITION. FOR THESE REASONS, WE RECOMMEND DO NOT RETURN THIS PRODUCT TO THE STORE THE FOLLOWING: DO NOT USE Z -Wave” DEVICES TO CONTROL ELECTRIC HEATERS OR ANY OTHER APPLIANCES WHICH MAY PRESENT A HAZARDOUS CONDITION DUE TO UNATTENDED OR UNINTENTIONAL OR AUTOMATIC POWER ON CONTROL.
Introduction:
This product can be operated in any Z-Wave network with other Z-Wave Plus certified devices from other manufacturers. This product is a Multipurpose Sensor, it has a door/window sensor and Temperature Humidity sensor. This product is battery power, It sleeps most of the time. MSE3OZ is a security- enabled Z-Wave Plus device. Security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product. The GENERIC_TYPE of the MSE3OZ is GENERIC_TYPE_SENSOR_NOTIFICATION The SPECIFIC TYPE of the MSE3OZ is SPECIFIC_TYPE_NOTIFICATION_SENSOR
Key Features:
—Checks and sends the status of the gate
—Detects and sends ambient temperature
—Detects and sends ambient humidity
—Support Association Group and Auto Report switch status
—Support firmware upgrades via Over-the-air (need Gateways support)
Product Overview:
A. z-wave program button
B. Magnet detection point
C. Temperature and humidity detection point
D. The magnet
E. Power: CR2450 3V
Key function description Function
1: quickly press 3x button: inclusion (only if the sensor is not included in
network)quickly press 3x button: exclusion
Function 2: quickly press the 5x button: Wake up the device
Function 3: Press click Z-Wave button 3 times quickly, and hold the third time
for at least 10 seconds. to restore the device to the factory.
(Node: Please use this procedure only when the network primary controller is
missing or otherwise inoperable.)
Adding Your Device To A Hub
The device support two methods of inclusion, When using a Z-Wave Flu’
certified controller choose Network Wide Inclusion or SmartStart, Network Wide
Inclusion To A Z-Wave’ Network 1, Refer to your primary controller
instructions to process the inclusion/exclusion setup procedure. 2, When
prompted by your primary controller, click the z-wave button three times in
one second. The device is compatible with SmartStart SmartStart enabled
products can be added into a Z-Wave’ network by scanning the Z-Wave
QR Code found on the top of the outlet or the back of the box with a
controller providing SmartStart inclusion. No further action is required and
the SmartStart product will be added automatically within 10 minutes of being
switched on and in the network vicinity.
QR CODE
the QR code is stuck to the side of the case, DSK is included in the QR code.
DSK
The DSK code can be found on the DSK label which is attached to the packaging
box.
Command Class
Command Clas | Version | Required Security Class |
---|---|---|
Z-Wave Plus Info | V2 | none |
Configuration | V4 | highest granted |
Association | V3 | highest granted |
Multi-Channel Association | V4 | highest granted |
Association Group Information | V3 | highest granted |
Transport Service | V2 | none |
Version | V3 | highest granted |
Manufacturer Specific | V2 | highest granted |
Device Reset Locally | V1 | highest granted |
Powerlevel | VI_ | highest granted |
Security 2 | V1 | none |
Supervision | V1 | none |
Firmware Update Meta Data | V5 | highest granted |
Battery | V1 | highest granted |
Indicator | V3 | highest granted |
Sensor Binary | V2 | highest granted |
Notification | V8 | highest granted |
Sensor Multilevel | V11………………………………………..highest granted | |
Wake Up | V2 ………………………….. …………….highest granted |
Z-Wave™ Configuration Parameters
You may use the below configuration parameters to change the settings of the corresponding functionality. The device needs to be woken up during setup
Support for Notification
Type | Events | Description |
---|---|---|
Access Control(0x06) | Ox16(Window/Door is open) | Open status. |
Access Control(0x06) | 0x17(VVindow/Door is closed) | Close status. |
Heat Alarm(0x04) | Ox02(Overheat) 0x06(Underheat) | Air temperature is high. Air |
temperature is low_
Weather Alarm(Ox 10)| 0x02(Weather Alarm)| Air humidity is high or low.
Basic Set Mapping
• Basic CC does not map to any Command Class.
Indicator Command Class
• The indicator (blue color) will flash according to the indicator set
command received from HUB.
Support for Association Groups
Association Group
ID | Name | Node Count | Profile | Function |
---|---|---|---|---|
1 | Lifeline | 5 | General: Lifeline | Device Reset Locally Notification: |
Issued when Factory Reset is performed. Battery Report: Issued
periodically to report the current battery level; Issued when the battery
becomes low. Sensor Binary Report: Issued when Magnet is away or near.
Notification Report(Typezt0x06; Everet=0x16: Issued when sensor state is
changed to be Open Status. Notification Report(Typei=0x06:Event=0x17):
Issued when sensor state is changed to be Close Status. Indicator Report:
Issued when included successfully. Sensor Multilevel Report: Issued when
air temperature changed exceeds the value determined by Parameter 6; Issued
when air humidity changed exceeds the value determined by Parameter 7.
2| 3asic Set when door triggered| 5| Notification: Access Control| Basic
Set: Issued when Magnet is away or near.(The Basic Set Value is determined
by Parameter 13)
3| Basic Set when temperature high| 5| Notification: Heat Alarm| Basic
Set: Issued when the air temperature exceeds the value determined by
Parameter 8.
4| Basic Set when temperature low| 5| Notification: Heat Alarm| Basic
Set: Issued when the air temperature exceeds the value determined by
Parameter 9.
5| Basic Set when humidity high| 5| Notification: Weather| Basic Set:
Issued when the air humidity exceeds the value determined by Parameter 10.
6| Basic Set when humidity low| 5| Notification: Weather| Basic Set:
Issued when the air humidity exceeds the value determined by Parameter 11.
Restoring Factory Defaults
MSE302 is removed from the network and will be restored to the factory setting All Configuration Parameters values and Association information will be restored to factory default settings and excluded from the network. Manual Reset: Press click Z-Wave button 3 times quickly, and hold the third time for at least 10 seconds. to restore the device to the factory. Remark: All the settings and data will be permanently deleted. Please use this procedure only when the network primary controller is missing or otherwise inoperable.