qtx 151.605UK Derby 9 LED Light Effect User Manual
- June 6, 2024
- qtx
Table of Contents
Item ref: 151.605UK
User Manual
Derby 9
LED Light Effect
Please read through this manual thoroughly before use, any damage caused by
misuse of the product will not be covered by warranty.
Thank you for choosing the Derby 9, a classic multi-color derby effect with
multiple beams twisting information. Nine different colored 3 Watt LEDs
deliver vivid colored patterns, split through precision optics for wide area
coverage.
Control via DMX512 or infra-red remote control for an auto program or sound
activation offers versatile operation modes for mobile discos, stage shows may
form part of a larger lighting installation.
In the box:
Your Derby 9 should arrive with you in a single carton in good condition. The carton should contain 1 x main unit with bracket, 1x remote control, 1 x UK IEC mains lead, and 1 x manual.
Warning:
To prevent the risk of fire or electric shock, do not expose the unit to rain or damp environments. In the event of a spillage, disconnect the mains and allow the unit to dry out naturally. Qualified personnel should then check the unit before continuing use.
**** Please do not open the cover, contains high voltage. This product is not
serviceable or repairable by the end-user.
Please refer to qualified personnel for service and repair.
www.avsl.com
151.605UK User Manual
Placement:
- Use the included mounting bracket to fix to a stand or lighting truss
- Use secondary safety fixings if mounting overhead
- Keep away from damp or dusty environments
- Ensure adequate air-flow around the fixture housings
Ensure adequate access to controls and connections
Cleaning:
- Use a soft cloth with a neutral detergent to clean the casing as required
- Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
- Do not use strong solvents for cleaning the unit
Rear panel controls:
- LCD display
- Manual control buttons
- Microphone
- DMX input
- DMX output
- IEC mains socket
Manual control menu:
Press the “ MENU ” button to enter the settings menu.
Press the “UP” and “ DOWN ” buttons to navigate through various setting
functions.
Press the “ ENTER ” button to save the desired setting.
Mode
| Function| Motor Speed|
Control Effects
---|---|---|---
A1| Auto| 1 to 9| Red + blue + warm white – ON/motor speed from slow to fast
A2| Amber + cool white + yellow – ON/motor speed from slow to fast
A3| Green + purple + UV – ON/motor speed from slow to fast
A4| 9 Colour jump change/motor speed from slow to fast
A5| 3 Colour jump change/motor speed from slow to fast
A6| Gradual change 1/motor speed from slow to fast/with no strobe effects
A7| Gradual change 2/motor speed from slow to fast/inc. strobe effects
S1| Sound| 0 to 20| Sound mode/colour change/including strobe effects/light
on/blackout
S2| Sound mode/color change/motor speed from fast to slow
SA| 1 to 10| Sound mode
S3| 1 to 20| Sound mode
FL| 1 to 9| Strobe mode
SALE| —| Slave mode
A001| 001 to 512| DMX control
Remote control:
The Derby 9 is supplied with an I.R. remote control for quick access to most
of the basic functions of the unit. This must be aimed at the front of the
unit where there is a remote receiver and has a maximum range of approximately
4m.
Controls are listed on the layout drawing below.
- Main unit on/off
- The motor on/off
- Sound show mode 1
- Strobe on/off
- Red/blue/warm white color group
- 9 Colour jump change
- Gradual change 2
- DMX on/off
- Sound show mode 2
- Sound show mode 3
- Orange/white/yellow color group
- Green/purple/UV color group
- 3 Colour jump change
- Gradual change 1
- +/- Increase/decrease speed
DMX mode:
The Derby 9 can be controlled by DMX signal, simply connect the DMX
signal source to the DMX input on the unit via a balanced XLR lead.
Extra fixtures can be controlled by the same DMX signal by looping through
the DMX out on the unit.
To enter DMX mode, select A001 from the menu and confirm the correct start
address by using the “ UP” and “ DOWN ” buttons and “ ENTER ” to
confirm.
This unit has 7 DMX channels as indicated in the table below:
Channel
| Function| DMX|
Description
---|---|---|---
CH1| Master dimmer| 0-7| Blackout
8-255| 0-100% linear dimmer
CH2| Red/blue/warm| 0-7| Blackout
white group| 8-255| 0-100% linear dimmer
CH3| Amber/yellow| 0-7| Blackout
Cool white group| 8-255| 0-100% linear dimmer
CH4| Green/purple| 0-7| Blackout
UV group| 8-255| 0-100% linear dimmer
CH5| Strobe| 0-10| No strobe
11-255| Strobe (6 different speeds)
CH6| Motor| 0-5| Motor stop
6-127| Static position
128-255| Oscillation (9 different speeds)
CH7| Choose program| 0-9| Manual channels 1-6 are available
10-39| A1 – red/blue/warm white – ON/motor speed from slow to fast
40-69| A2 – amber/cool white/yellow – ON/motor speed from slow to fast
CH7| Choose program| 70-99| A3 – green/purple/UV – ON/motor speed from slow to
fast
100-129| A4 – 9 color jump change/motor speed from slow to fast
130-159| A5 – 3 color jump change/motor speed from slow to fast
160-189| Gradual change 1/motor speed from slow to fast/with no strobe effects
190-219| Gradual change 2/motor speed from slow to fast/including strobe
effects
220-249| S1 – sound mode 1
250-255| S2 – sound mode 2
Specifications:
Power supply | 110-240Vac, 50/60Hz (IEC) |
---|---|
Power consumption | 30W |
Fuse rating | F3AL |
LED quantity | 9 x 3W |
LED color | Red, green, blue, amber, yellow, purple, WW, CW, UV |
DMX connection | 3-pin XLR in & out |
DMX channels | 7 |
Dimensions | 200 x 162 x 140mm |
Weight | 1.1kg |
Troubleshooting:
No power (mains) | Check mains voltage is correct and outlet is switched on |
---|
Check IEC lead and fuse (if fuse continually blows, refer to your dealer)
No light output| Check control panel mode settings
Check DMX settings from the controller (dimmer levels, blackout, etc.)
Unresponsive to DMX| Check that unit is in DMX mode and ensure DMX address
remains lit to confirm receiving DMX signal
Check DMX controller is not set to blackout
Check DMX controller is on correct fixture/page
Check master dimmer value
Check correct DMX address is set
Check DMX connection and leads
Overheating/ cutting out| Ensure adequate ventilation and unit is not too
close to a heat source
This product is classed as Electrical or Electronic equipment and should not
be disposed of with other household or commercial waste at the end of its
useful life.
The goods must be disposed of according to your local council guidelines.
Errors and omissions excepted.
Copyright© 2021 AVSL Group Ltd, Unit 2 Bridgewater Park,
Taylor Road, Trafford Park, Manchester. M41 7JQ.
AVSL (Europe) Ltd, Unit 3D North Point House,
North Point Bus. Park, New Mallow Road, Cork, Ireland.
Read User Manual Online (PDF format)