Semi automated mode (35341 and 35352) Semi-automated external defibrillator that can be administered on sudden cardiac arrest (SCA) patients. CU-SP2 is an easy-to-use, small, light and portable defibrillator with battery.

The AED automatically reads the sudden cardiac arrest (SCA) patient’s electrocardiogram (ECG) and determines if a cardiac arrest that requires defibrillation has occurred, so that licensed emergency medical technicians, medical professionals and the general public can easily operate it.

Manual mode (only 35352)

In manual mode, the user determines whether the patient needs a defibrillation shock or not. It is intended for use by health care professionals and emergency rescue personnel who have been trained in advanced cardiac life support

Innovative features: – Auto volume adjustment

It detects the ambient noise and automatically adjusts the volume of its prompts to make them audible over the background noise.

Smart pads – intelligent storage

The pre-connected “Smart” electrode pads are stored in an easy access compartment on the underside of the unit ensuring use in the shortest possible time. In addition, the visual frontal indicator shows if the connected pads are within their life expectancy. The indicator will change when the pads have only 3 months life left before their expiry date giving you time to arrange for replacements. It will change again when the expiry date is reached.

CPR detection

CPR is vital to ensure that the casualty has the best chances of survival. iPAD CU-SP2 detects if CPR is being performed with appropriate prompts, if not it encourages the responder to perform it.

Easy communication with CU-EX1 software

It allows to see and analyze information such as time of “power on”, the casualty’s heart rhythm and shocks delivered. It saves 3 events on the internal memory (up to 17 hours per event).

Wireless ECG transmission device (CU-EM1) – optional

In monitor mode, iPAD CU-SP2 uses Bluetooth to receive ECG data from CU-EM1 and displays it on the LCD screen.

Printer – optional

iPAD CU-SP2 supports connection to an external Bluetooth printer

iPAD CU-SP2 supports connection to an external Bluetooth printer

STANDARD ACCESSORIES

Adult PADS Disposable Li-ion battery pack Paper manual (GB, IT) Carrying bag CD manual in above languages

TECHNICAL SPECIFICATIONS

  • Defibrillator
  • Operating mode Semi-automatic (35341, 35352), manual (35352)
  • Waveform e-cube biphasic (Truncated exponential type)
  • Energy AED mode: 150/200J fixed or 150-150-200J energy escalating Manual mode: 2-200J, R-Sync (only 35352

Charging time

Charging time after CPR finished: at least 6 seconds
Sealing: waterjet proof IPX5 per IEC60529 (IP55) dust protected IP5X per IEC60529

Size – weight:

260x256x69.5 mm – 2.4 kg (including pad and battery)

User interface

User support: detailed voice and text prompts
CPR guidance: voice prompts for how to perform CPR for adult and child
Controls: on/off button, ”i“ button, shock button, soft keys
Indicator: graphic LCD display (status, user’s guide, ECG, heart rate, …..)
Sensing: pads expiry date, pads connection status CPR Monitoring, ECG Monitoring, Automatic Volume adjustment

Data recording and transmission

IrDA port SD card: for PC communication
Internal Memory (Nand-flash): ECG, Event
Storage capacity: multi recording 3 events / Max 17 hours for each event
Bluetooth: communication with the printer or ECG CU-EM1 Data review PC Programme: CU-EX1

Patient analysis system

Patient Analysis

Patient Analysis: Shockable Rhythms (Ventricular Fibrillation, Tachycardia) Sensitivity/Specificity meets AAMI DF80 Guideline Battery Standard Type: DC 12 Volt 4.2 Ah, Lithium manganese dioxide Capacity: Minimum 130 shocks (150J) or 5 hours ECG monitoring

Rechargeable (optional) Type: DC 11.1 Volt 1.9 Ah, Li-ion rechargeable Capacity: Minimum 60 shocks or 3 hours of operation

Altitude operating range

  • Altitude 0-5,000 m

ACCESSORIES FOR CU-SP2

  • 35344 Adult PADS – kit of 2 pcs – disposable
  • 35345 Pediatric PADS – kit of 2 pcs – disposable
  • 35346 Disposable Lithium battery LiMnO2 high capacity 4.2 Ah – spare
  • 35347 Rechargeable 10.8 V, 2.5 Ah Li-ion battery – optional
  • 35348 Battery charge dock + battery charger for 35347
  • 35349 SD card+ software for event recording download
  • 35350 Wireless ECG CU-EM1 for CU-SP2
  • 35351 Wireless printer for CU-SP2

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals