Istcontrol IRD4M Smart Mobile ID Reader Installation Guide
- June 6, 2024
- Istcontrol
Table of Contents
Istcontrol IRD4M Smart Mobile ID Reader
Safety instructions
Observe the following instructions to use the product safely and prevent any risk of injury or property damage.
-
Warning
Noncompliance of instructions could lead to serious injury or death. -
Installation
Do not install the product in a place with direct sunlight, moisture, dust, or soot.
A fire or electric shock may occur. -
Do not install the product in a place with heat from an electric heater.
A fire or electric shock may occur due to overheating. Install the product in a dry place. -
Install the product in a place with no electromagnetic interference.
Otherwise, product damage or electric shock may occur due to moisture. -
The user should not install or repair the product independently.
Otherwise, product damage or electric shock may occur. -
The user should not install or repair the product independently.
A fire, electric shock, or personal injury may occur.
If the product has been damaged due to independent installation or repair of the product by the user, free A/S service will not be provided. -
Operation
Do not allow liquids such as water, beverages, or chemicals get into the product. -
Caution
Noncompliance of instructions could lead to minor injury or product damage.
Installation
Do not install the power supply cable in a place where people pass by.
-
Product damage or physical injury may occur.
Do not install the product near a highly magnetic object such as a magnet, TV, (especially CRT) monitor, or speaker. -
A product failure may occur.
If installing the product outside where the product is completely exposed,
it is recommended to install the product together with the enclosure.
Keep the minimum separation distances between the devices when installing
multiple devices.
Operation
Do not drop the product or apply an impact to the product.
- A product failure may occur.
When cleaning the product, wipe the product with a soft and dry cloth and no water, benzene or alcohol.
- Otherwise, a product failure may occur.
Introduction
Components
Name of each Part
PIN | English |
---|
Color
1| PWR +VDC| Red
2| PWR GND| Black
3| WG DO| Green
4| WGD1| White
5| 485 TRXA| Yellow(Gray Stripe)
6| 485 TRXB| White (Gray stripe)
7| RED LED| Brown
8| GRN LED| Orange
9| BUZZER| Yellow
10| TAMPER| Violet
11| EXT IN1| SKY
12| EXT IN2| Blue
13| EXT IN3| Pink
14| EXT IN4| Gray
Installation
Determine the correct position to install the bracket. Fix the bracket firmly using fixing screws through the bracket to the position where IRD4M will be installed.
Put the reader on top of the bracket and slightly to the right side of bracket
and slide it from right to left inserting the comb pattern side of the bracket
into the groove on the back of the reader.
Press the reader firmly toward the wall until you hear click sound.
Product Specification
Base Part Number
| ****
Input Voltage (VDC)
| Current| ****
Operation Temperature
| ****
Cable Length
---|---|---|---|---
Standby AVG
| ****
Max AVG
| ****
Peak
IRD4M
| ****
12V
| ****
250mA
| ****
300mA
| ****
400mA
| ****
-20℃ ~ 60℃
| Wiegand : 22 AWG (150m)
24 AWG (90m) RS-485 : 4 AWG (1,200m)
24 AWG (500m)
- Controls LED through LED Control- RED LED, GRN LED Input.
- BUZZER Control – Controls the buzzer output through the buzzer input (Yellow).
- Optical Tamper – Once activated, and when the mounting plate is removed, the optical Tamper is activated.
- Icon LED Control – Controls the four icon LED through EXT IN 1~4 line.
- Using the integrated Wiegand version, when the integrated Wiegand version Firmware of DNX control is applied, also the door contact sensor signal and the Exit button signal line is connected to EXT IN 3(pink) and EXT IN 4(gray) line of the reader. it delivers to DNX control through the communication between the door contact signal ad the lock status signal.
Dimensions
FCC compliance information
FCC Compliance Statement
This device complies with part 15 of the FCC rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class A digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This
equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Modifications not expressly approved by the manufacturer could void the user’s
authority to operate the equipment under FCC rules.
FCC Caution
Any changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate this equipment. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
FCC ID : 2AZS5IRD4M
EU Declaration of Conformity (CE)
This product is CE marked according to the provisions of the Radio Equipment
Directive (RED) 2014/53/EU. Hereby, ISTCONTROL declares that this product is
in compliance with the essential requirements and other relevant provisions of
Radio Equipment
Directive (RED) 2014/53/EU.
- Bluetooth Transmit Power: 2.1dBm
- Bluetooth Frequency: 2402~2480 MHz
- NFC Frequency: 13.56 MHz
- RFID Frequency: 13.56 MHz
For more information, contact us at the following contact information.
I STCONTROL, Inc.
Access Control & Integrated Solution Provider
1203, 37, Maebongsan-ro, Mapo-gu, Seoul, Republic of Korea 03909
TEL: 82+ 070-4194-1993
Website :www.istcontrol.com
Email:info@istcontrol.com